SourceMed · Shelf #904 in the ask interface

Cochlear implantation for single-sided deafness: the CINGLE randomised trial

Shelf #904 · Eyes, skin, nose & allergy

POSSIBLE

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2021–2025.

Last source check: 2026-11-13.

Source correction status: no correction or retraction found at the last source check (2026-11-13).

Question

In adults with single-sided deafness, does a cochlear implant beat a bone-conduction device or a CROS hearing aid on speech perception in noise, sound localisation, and tinnitus?

Balance of the evidence

POSSIBLE: One randomised programme (CINGLE, 120 patients) reports twice — at 3–6 months and at 24 months — that cochlear implantation outperformed bone-conduction devices, CROS aids and no treatment on speech perception in noise in the configurations that matter, and was the only option to improve sound localisation and tinnitus burden. But it is a single programme, the device groups were partly self-selected after the randomised trial periods (only 28 of 120 received an implant), and masking is impossible — a single-programme ceiling of POSSIBLE.

MeSH: Bone Conduction · Cochlear Implantation/methods · Cochlear Implants · Hearing Aids · Hearing Loss, Unilateral/therapy · Sound Localization · Speech Perception

Cards (3)

Card 1 — Peters 2021 (CINGLE, short-term): cochlear implantation beat BCD, CROS and baseline on speech in noise, localisation and tinnitus at 3–6 months

Study: Randomised controlled trial (three-arm, with post-trial device choice)

Population: 120 adults with single-sided deafness randomised to cochlear implantation, or trial periods of bone-conduction device then CROS, or CROS then bone-conduction device; after allocation the groups were implant 28, bone-conduction device 25, CROS 34, and no treatment 26 (7 patients did not receive their allocated intervention); the abstract does not state mean age or sex mix.

Summary: CINGLE, short-term (2021): cochlear implantation beat BCD, CROS and baseline on speech in noise, localisation and tinnitus at 3–6 months.

Result: With speech and noise from the front, the implant group performed significantly better than baseline and than the other groups. With speech directed to the poor ear, all treatment groups improved on baseline; with speech to the better ear and noise to the poor ear, the bone-conduction and CROS groups performed worse than baseline while the implant group improved. Only the implant group improved in sound localisation and tinnitus burden. All treatment groups improved on disease-specific quality of life vs baseline.

Watch out: After the randomised trial periods, patients chose their device — so the compared groups are part-randomised, part-self-selected, and the implant arm is the smallest (28). Effect sizes are described qualitatively in this report; the 24-month report carded below carries the numbers.

Source: Peters JPM et al. Short-term outcomes of cochlear implantation for single-sided deafness compared to bone conduction devices and contralateral routing of sound hearing aids - Results of a Randomised controlled trial (CINGLE-trial). PLoS One. 2021;16(10):e0257447. PMID: 34644322. Registry ID: Netherlands Trial Register NTR4580, stated in the record's abstract; the MEDLINE record carries no databank SI field.

Card 2 — van Heteren 2025 (CINGLE, 24 months): implant speech-in-noise scores beat BCD by up to 4.7 dB and CROS by up to 5.3 dB

Study: Randomised clinical trial, 24-month follow-up report of the CINGLE programme

Population: 120 adults with single-sided deafness (60 female, 50.0%; mean age 53.0 years, SD 12.1), with 28 receiving a cochlear implant, 25 a bone-conduction device, 34 a CROS aid and 26 no treatment at the start of follow-up; single-centre.

Summary: CINGLE, 24 months (2025): implant speech-in-noise scores beat BCD by up to 4.7 dB and CROS by up to 5.3 dB.

Result: At 24 months, speech reception thresholds in noise favoured the implant group over the bone-conduction group (difference −4.7 dB in the speech-to-better-ear configuration, 95% CI −6.6 to −3.0; −2.2 dB, −4.6 to −1.1, speech to poor ear), over CROS (−1.3 dB, −1.7 to −0.2, speech and noise in front; −5.3 dB, −6.0 to −3.1, speech to better ear), and over no treatment (−6.3 dB, −7.5 to −4.9, speech to poor ear). Bone-conduction and CROS each beat no treatment by −4.1 dB when speech was directed to the poor ear, but were worse than no treatment by +4.0 and +4.6 dB when noise was directed to the poor ear. Self-reported speech perception was significantly better in the implant group than all others.

Watch out: Same trial, second report — counted once as evidence. The routing devices' harm in the noise-to-poor-ear configuration is mechanistically expected (they pipe noise into the good ear) and is part of the comparison's honesty, but group sizes remain small and self-selection after the trial periods persists.

Source: van Heteren JAA et al. Speech Perception in Noise After Cochlear Implantation for Single-Sided Deafness: A Randomized Clinical Trial. JAMA Otolaryngol Head Neck Surg. 2025;151(3):211-219. PMID: 39820302. Registry ID: trialregister.nl NL4457, stated in the record's abstract (its databank field labels it ClinicalTrials.gov: NL4457).

Card 3 — Synthesis: one programme, consistent direction, real design caveats — POSSIBLE

Study: Synthesis

Population: Synthesis of the cards above: the CINGLE programme's two reports (120 randomised patients; 28 implanted).

Summary: One programme, consistent direction, real design caveats — POSSIBLE.

Result: Cochlear implantation is the only single-sided-deafness option that restores something like binaural advantage in these data — better speech in noise in every configuration, plus localisation and tinnitus gains the routing devices cannot offer — and it is also the only surgical, most expensive option, tested in one centre's programme. POSSIBLE. Hearing aids for cognition in bilateral loss (ACHIEVE) live on Shelf #350 and are not re-carded here.

Watch out: Two reports of one trial are one trial: anyone citing 'two studies' for this claim has double-counted CINGLE.

Source: Synthesis of Peters JPM et al. PLoS One. 2021;16(10):e0257447. PMID: 34644322; van Heteren JAA et al. JAMA Otolaryngol Head Neck Surg. 2025;151(3):211-219. PMID: 39820302. Registry IDs as on the individual cards.