SourceMed · Shelf #9052 in the ask interface
Leaving aspirin out of the regimen after a HeartMate 3 left ventricular assist device (ARIES-HM3, 628 randomised): aspirin avoidance was noninferior for haemocompatibility events (74% versus 68% event-free at 12 months) and cut nonsurgical bleeding (relative risk 0.66)
Shelf #9052 · Heart, vessels, blood pressure & clotting
POSSIBLE (benefit) — one randomised, double-blind, placebo-controlled trial (628 patients randomised; 589 in the primary analysis) found aspirin avoidance noninferior on survival free of major nonsurgical haemocompatibility events at 12 months (74% event-free on placebo versus 68% on aspirin; difference 6.0 percentage points, lower 1-sided 97.5% CI −1.6% against a −10% margin) and associated with fewer nonsurgical bleeding events (relative risk 0.66; 95% CI 0.51–0.85) with no increase in stroke or other thromboembolic events; a single-trial claim is Tier C
Stamped: 2026-11-28.
Evidence published: 2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with advanced heart failure supported by a fully magnetically levitated left ventricular assist device (HeartMate 3) and treated with a vitamin K antagonist, is avoiding aspirin noninferior to taking aspirin 100 mg daily for survival free of major haemocompatibility events, and does it reduce bleeding?
Balance of the evidence
POSSIBLE (benefit) — ARIES-HM3 randomised 628 patients with advanced heart failure implanted with a fully magnetically levitated left ventricular assist device (HeartMate 3, Abbott — named as the publication names the device under test) to aspirin 100 mg daily (314) or placebo (314), both on top of a vitamin K antagonist, across 51 centres in 9 countries; 589 patients (296 placebo, 293 aspirin) formed the primary analysis population, and median follow-up was 14 months. More patients were alive and free of major nonsurgical haemocompatibility events at 12 months in the placebo group (74%) than in the aspirin group (68%); noninferiority of placebo was demonstrated (absolute between-group difference 6.0% improvement in event-free survival with placebo [lower 1-sided 97.5% CI, −1.6%]; P<.001, against a −10% margin). Aspirin avoidance was associated with reduced nonsurgical bleeding events (relative risk 0.66 [95% confidence limit, 0.51–0.85]; P =.002) — a 34% relative reduction — with no increase in stroke or other thromboembolic events. POSSIBLE: a well-blinded single trial showing a drug can be safely omitted with less bleeding; held at POSSIBLE and Tier C because it is one trial in one device type.
MeSH: Male · Humans · Female · Aspirin/adverse effects · Heart-Assist Devices/adverse effects* · Fibrinolytic Agents/adverse effects · Double-Blind Method · Heart Failure/physiopathology* · Stroke/etiology/prevention & control/drug therapy* · Platelet Aggregation Inhibitors/adverse effects · Hemorrhage/etiology · Thromboembolism/etiology/prevention & control*
Cards (2)
Card 1 — ARIES-HM3: aspirin avoidance noninferior, with a third less nonsurgical bleeding in relative terms (Mehra 2023, JAMA — randomised double-blind placebo-controlled trial, 628 randomised): event-free survival at 12 months 74% without aspirin versus 68% with it
Study: Randomized controlled trial (international, double-blind, placebo-controlled)
Population: 628 patients with advanced heart failure implanted with a fully magnetically levitated left ventricular assist device at 51 centres in 9 countries, randomised 1:1 to aspirin (100 mg/d; 314) or placebo (314) in addition to vitamin K antagonist therapy; the primary analysis population was 589 patients (296 placebo, 293 aspirin), of whom 77% were men. Enrolment ran from July 2020 to September 2022, with a median follow-up of 14 months. The composite primary end point, assessed for noninferiority of placebo with a −10% margin, was survival free of a major nonsurgical (more than 14 days after implant) haemocompatibility-related adverse event — stroke, pump thrombosis, major bleeding, or arterial peripheral thromboembolism — at 12 months.
Summary: ARIES-HM3: aspirin avoidance noninferior, with a third less nonsurgical bleeding in relative terms (Mehra 2023, JAMA — randomised double-blind placebo-controlled trial, 628 randomised): event-free survival at 12 months 74% without aspirin versus 68% with it
Result: More patients were alive and free of hemocompatibility events at 12 months in the placebo group (74%) versus those taking aspirin (68%). Noninferiority of placebo was demonstrated (absolute between-group difference, 6.0% improvement in event-free survival with placebo [lower 1-sided 97.5% CI, −1.6%]; P<.001). Aspirin avoidance was associated with reduced nonsurgical bleeding events (relative risk, 0.66 [95% confidence limit, 0.51–0.85]; P = .002) with no increase in stroke or other thromboembolic events, a finding consistent among diverse subgroups of patient characteristics.
Watch out: The device under test is one specific fully magnetically levitated pump (HeartMate 3, Abbott) whose thrombosis profile is unusually favourable; the result must not be read across to older axial-flow devices, where aspirin omission has not been randomised. The primary analysis excluded 39 of 628 randomised patients, and 12 months is early in the life of a durable device.
Source: Mehra MR et al. Aspirin and Hemocompatibility Events With a Left Ventricular Assist Device in Advanced Heart Failure: The ARIES-HM3 Randomized Clinical Trial. JAMA. 2023. PMID: 37950897. Registry ID: NCT04069156. MeSH: Male · Humans · Female · Aspirin/adverse effects · Heart-Assist Devices/adverse effects* · Fibrinolytic Agents/adverse effects · Double-Blind Method · Heart Failure/physiopathology* · Stroke/etiology/prevention & control/drug therapy* · Platelet Aggregation Inhibitors/adverse effects · Hemorrhage/etiology · Thromboembolism/etiology/prevention & control*
Card 2 — Synthesis — POSSIBLE (benefit): one blinded trial supports omitting aspirin with this pump — benefit is bleeding avoided, not events prevented
Study: Synthesis
Population: One randomised trial: Mehra 2023 ARIES-HM3 (628 randomised; 589 in the primary analysis). Documented N = 628 randomised patients.
Summary: Synthesis — POSSIBLE (benefit): one blinded trial supports omitting aspirin with this pump — benefit is bleeding avoided, not events prevented
Result: Aspirin avoidance met noninferiority on the haemocompatibility composite (74% versus 68% event-free at 12 months) and reduced nonsurgical bleeding events (relative risk 0.66; 95% CI 0.51–0.85) with no increase in stroke or other thromboembolic events. The benefit is the removal of a drug's harm, shown in a single trial in a single device — POSSIBLE.
Watch out: All patients remained on a vitamin K antagonist — this shelf is about aspirin only, and it does not support reducing anticoagulation itself. Longer-term pump thrombosis and stroke rates beyond the trial's median 14 months are outside this record.
Source: Synthesis of the report carded above; no additional source.