SourceMed · Shelf #9090 in the ask interface

The hypercapnic ventilatory response: ventilation stays near basal until end-tidal CO2 reaches a recruitment threshold around 46–49 mm Hg, then rises about 2.5 L/min per mm Hg — and the threshold is the reproducible part (test–retest variation 3–4%) while the slope varies 19–33%

Shelf #9090 · Lungs, breathing & sleep

PHYSIOLOGY — ESTABLISHED — rebreathing studies in healthy humans (documented N = 64, plus a case-control study whose healthy-group numbers are carded without a documented subgroup N) put the hypercapnic ventilatory response slope at about 2.5 L/min per mm Hg (2.52, SD 1.27, by the Read method) and the ventilatory recruitment threshold at 46.0 mm Hg in older healthy controls and 48.8 mm Hg in young healthy adults (hyperoxic Duffin method); the threshold is highly reproducible (within-subject variation 3.0–3.8%) while slope and basal ventilation vary much more (18.5–32.7%).

Stamped: 2026-11-28.

Evidence published: 1985–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, what does the ventilatory response to rising carbon dioxide look like when measured by rebreathing — at what end-tidal CO2 does ventilation start to rise (the recruitment threshold), how steep is the rise above it (the slope), and how reproducible are the two numbers?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED — three measurement studies and one case-control study describe the same two-part response: below a recruitment threshold, ventilation stays at its basal level; above it, ventilation rises roughly linearly with end-tidal CO2 at about 2.5 L/min per mm Hg (2.52, SD 1.27 in 14 volunteers by Read rebreathing, unchanged at 2.24, SD 1.14 after repeated apnoeas). Thresholds by the hyperoxic Duffin method were 46.0 mm Hg in healthy controls aged 45+ and 48.8 mm Hg in young healthy adults. Reliability splits the pair: in 20 healthy humans the recruitment threshold's within-subject coefficient of variation was only 3.0–3.8% while chemoreflex sensitivity varied 18.5–32.7%, and in 30 young adults the slope's test–retest intraclass correlation was 0.828 — above the 0.70 level that suffices for comparing groups, below the 0.90 ideal for decisions about an individual patient. PHYSIOLOGY — ESTABLISHED: the CO2 response is a threshold-plus-slope system, and the threshold is its stable, individually repeatable feature.

MeSH: Adult · Apnea/metabolism, physiopathology · Carbon Dioxide/metabolism · Female · Humans · Hypercapnia/metabolism, physiopathology · Male · Oxygen Consumption/physiology · Pulmonary Ventilation* · Respiratory Mechanics

Cards (5)

Card 1 — Read rebreathing slope: 2.52 (SD 1.27) L/min per mm Hg (Andersson 2009, European Journal of Applied Physiology — 14 healthy volunteers), unchanged after repeated apnoeas (2.24, SD 1.14)

Study: Physiology experiment (rebreathing measurement, within-subject)

Population: 14 healthy volunteers who performed five maximal-duration apnoeas with face immersion and two hypercapnic ventilatory response measurements by the Read rebreathing method, one as control and one within 2 minutes of the last apnoea; breath-hold time rose 43% across the apnoea series (P < 0.001).

Summary: Read rebreathing slope: 2.52 (SD 1.27) L/min per mm Hg (Andersson 2009, European Journal of Applied Physiology — 14 healthy volunteers), unchanged after repeated apnoeas (2.24, SD 1.14)

Result: The slope of the hypercapnic ventilatory response was 2.52 (SD 1.27) L/min per mm Hg in the control test and 2.24 (SD 1.14) L/min per mm Hg after the apnoea series (not significant) — repeated apnoeas did not change CO2 sensitivity in the short term, so the change in breath-hold time is not explained by a change in the response.

Watch out: The slope's standard deviation (1.27 on a mean of 2.52) is the story as much as the mean: healthy individuals differ about twofold in CO2 sensitivity, so 2.5 is a centre, not a norm to judge one person against.

Source: Andersson JP et al. Repeated apneas do not affect the hypercapnic ventilatory response in the short term. European journal of applied physiology. 2009. PMID: 19018556. Registry ID: none in the record. MeSH: Adult · Apnea/metabolism, physiopathology · Carbon Dioxide/metabolism · Female · Humans · Hypercapnia/metabolism, physiopathology · Male · Oxygen Consumption/physiology · Pulmonary Ventilation* · Respiratory Mechanics

Card 2 — Duffin method thresholds: 46.0 mm Hg in healthy controls, 48.8 mm Hg in young healthy adults (Eser 2024, Frontiers in Physiology — case-control study; healthy subgroup N not documented in the record)

Study: Physiology measurement (case-control, Duffin rebreathing)

Population: Patients with chronic coronary syndrome or heart failure with inefficient ventilation, healthy controls aged 45 years and over, and young healthy adults under 35, all tested with the Duffin rebreathing method (hyperoxic and hypoxic runs) for resting end-tidal CO2, ventilatory recruitment threshold and slope; the record does not state the healthy subgroups' sizes, printed here as N not documented in the record for those subgroups.

Summary: Duffin method thresholds: 46.0 mm Hg in healthy controls, 48.8 mm Hg in young healthy adults (Eser 2024, Frontiers in Physiology — case-control study; healthy subgroup N not documented in the record)

Result: Hyperoxic ventilatory recruitment thresholds were 46.0 mm Hg in the healthy controls and 48.8 mm Hg in the young healthy adults (vs 42.1 and 43.2 mm Hg in the patient groups). Neither hypoxic thresholds nor hyper- or hypoxic slopes differed significantly between patients and controls; median ventilation/CO2-production slopes on exercise testing were 30.5 in controls and 28.0 in young adults.

Watch out: Healthy values come from a case-control study designed around patients, with subgroup sizes not stated in the record — the thresholds are carded as reference points, not as a normative study. The record carries no MeSH.

Source: Eser P et al. Excess ventilation and chemosensitivity in patients with inefficient ventilation and chronic coronary syndrome or heart failure: a case-control study. Frontiers in physiology. 2024. PMID: 39911179. Registry ID: NCT05057884 (as stated in the record). MeSH: none in the record

Card 3 — Reliability: threshold variation only 3.0–3.8%, slope variation 18.5–32.7% (Jensen 2010, Respiratory Physiology & Neurobiology — repeated Duffin testing, 20 healthy humans)

Study: Physiology measurement (test–retest reliability study)

Population: 20 healthy humans tested repeatedly (within- and between-day) with Duffin's modified hyperoxic and hypoxic rebreathing procedure, yielding basal ventilation, the ventilatory recruitment threshold, and chemoreflex sensitivity above the threshold.

Summary: Reliability: threshold variation only 3.0–3.8%, slope variation 18.5–32.7% (Jensen 2010, Respiratory Physiology & Neurobiology — repeated Duffin testing, 20 healthy humans)

Result: Within- and between-day intraclass correlation coefficients for the parameters ranged from 0.62 to 0.93. Within-subject coefficients of variation were 24.6–30.7% for basal ventilation and 18.5–32.7% for chemoreflex sensitivity, but only 3.0–3.8% for the ventilatory recruitment threshold. In plain terms, against the usual reliability yardsticks — 0.70 suffices for comparing groups and 0.90 is the ideal for a measure used for individual-patient decisions — the threshold behaves like a stable individual trait while the slope is a group-level measure.

Watch out: Reliability is not validity: a repeatable threshold still depends on the rebreathing method used, and hyperoxic and hypoxic runs answer slightly different (central vs combined) questions.

Source: Jensen D et al. Variability of the ventilatory response to Duffin's modified hyperoxic and hypoxic rebreathing procedure in healthy awake humans. Respiratory physiology & neurobiology. 2010. PMID: 20035904. Registry ID: none in the record. MeSH: Chemoreceptor Cells/physiology · Feedback, Physiological/physiology · Female · Humans · Hyperoxia/physiopathology · Hypoxia/physiopathology · Longitudinal Studies · Male · Pulmonary Ventilation/physiology · Reproducibility of Results · Respiratory Function Tests · Time Factors · Wakefulness · Young Adult

Card 4 — Method check: adding inspiratory-capacity manoeuvres does not change the response (Shekarloo 2025, Journal of Applied Physiology — 30 young healthy participants); slope test–retest intraclass correlation 0.828

Study: Physiology measurement (randomised-order method comparison)

Population: 30 young healthy participants (15 male, 15 female) completing two modified Duffin CO2 rebreathing tests on separate days in randomised order, one with serial inspiratory-capacity manoeuvres every 2 minutes and one without; basal ventilation, recruitment threshold and slope compared between conditions.

Summary: Method check: adding inspiratory-capacity manoeuvres does not change the response (Shekarloo 2025, Journal of Applied Physiology — 30 young healthy participants); slope test–retest intraclass correlation 0.828

Result: There were no between-condition differences in basal ventilation, recruitment threshold or slope (all P > 0.05). Intraclass correlation coefficients were 0.745 for basal ventilation, 0.692 for the recruitment threshold and 0.828 for the slope. On the usual yardsticks — 0.70 suffices for comparing groups, 0.90 is the ideal for individual-patient decisions — the slope's 0.828 clears the group-comparison level but not the individual-decision ideal.

Watch out: A methods paper: it certifies that lung-volume manoeuvres can be added to the test without distorting it, and its absolute slope and threshold values are not reported in the record — only the agreement statistics are carded.

Source: Shekarloo P et al. Determining operating lung volumes during a CO2 rebreathing test: does the inspiratory capacity maneuver influence the hypercapnic ventilatory response? Journal of applied physiology (Bethesda, Md. : 1985). 2025. PMID: 40139680. Registry ID: none in the record. MeSH: Humans · Male · Female · Hypercapnia*/physiopathology, metabolism · Carbon Dioxide*/metabolism · Adult · Young Adult · Lung*/physiology · Inspiratory Capacity*/physiology · Lung Volume Measurements/methods · Pulmonary Ventilation*/physiology · Tidal Volume/physiology · Inhalation/physiology · Respiratory Function Tests/methods

Card 5 — Synthesis — PHYSIOLOGY — ESTABLISHED: a threshold near 46–49 mm Hg and a slope near 2.5 L/min per mm Hg, with the threshold the repeatable feature

Study: Synthesis

Population: 4 studies: Andersson 2009 (14), Jensen 2010 (20), Shekarloo 2025 (30), and Eser 2024 (healthy subgroup N not documented in the record). Documented N = 64.

Summary: Synthesis — PHYSIOLOGY — ESTABLISHED: a threshold near 46–49 mm Hg and a slope near 2.5 L/min per mm Hg, with the threshold the repeatable feature

Result: Read and Duffin rebreathing converge on the same picture: ventilation holds at basal until end-tidal CO2 crosses a recruitment threshold (46.0–48.8 mm Hg in the healthy groups carded), then rises at about 2.5 L/min per mm Hg with wide individual spread. Test–retest data make the threshold the trustworthy individual number (variation 3.0–3.8%) and the slope a group-level one (variation 18.5–32.7%; intraclass correlation 0.828). No report was refused; the classic Rebuck & Campbell 1972 record was not carded because its PubMed record carries no abstract.

Watch out: Methods differ (Read vs Duffin, hyperoxic vs hypoxic runs) and each method's numbers belong to that method — cross-method pooling would manufacture a precision none of the studies claims.

Source: Synthesis of the reports carded above; no additional source.