SourceMed · Shelf #9113 in the ask interface
Femoral neck fracture fixation: a sliding hip screw did not cut reoperations versus multiple cancellous screws in the 1,108-patient FAITH trial (20% vs 22%), and a 10-trial meta-analysis found no difference in reoperation, nonunion or avascular necrosis
Shelf #9113 · Bones & joints
POSSIBLE (the treatment made no difference) — 1 large international randomised trial (FAITH, 1,108 randomised) plus a meta-analysis of 10 randomised trials (1,934 patients, overlapping FAITH): reoperation did not differ (FAITH 20% vs 22%, HR 0.83, 95% CI 0.63 to 1.09); FAITH found more avascular necrosis with the sliding hip screw (9% vs 5%), which the pooled analysis did not confirm.
Stamped: 2026-11-28.
Evidence published: 2017–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults aged 50 or older with a low-energy femoral neck (hip) fracture treated by internal fixation, does a sliding hip screw reduce reoperation within 24 months compared with multiple cancellous screws?
Balance of the evidence
POSSIBLE (the treatment made no difference) — 1 large international randomised trial (FAITH, 1,108 randomised) plus a meta-analysis of 10 randomised trials (1,934 patients, overlapping FAITH): reoperation did not differ (FAITH 20% vs 22%, HR 0.83, 95% CI 0.63 to 1.09); FAITH found more avascular necrosis with the sliding hip screw (9% vs 5%), which the pooled analysis did not confirm. Composition: FAITH is the only individually carded trial; the meta-analysis pools 10 trials including FAITH, so its 1,934 patients are not added to FAITH's 1,108 — no combined total is printed. The one consistent between-implant difference is greater intraoperative blood loss with the sliding hip screw (pooled mean difference 110.01 mL). POSSIBLE: on reoperation and healing, the choice between a sliding hip screw and cancellous screws made no difference in the trials carded here.
MeSH: Aged · Aged, 80 and over · Bone Screws · Equipment Design · Female · Femoral Neck Fractures/surgery · Femur Head Necrosis/etiology · Fracture Fixation, Internal/adverse effects,instrumentation,methods · Fracture Healing · Humans · Kaplan-Meier Estimate · Male · Quality of Life · Reoperation/statistics & numerical data · Single-Blind Method · Treatment Outcome
Cards (3)
Card 1 — FAITH trial: reoperation 20% vs 22% at 24 months — no advantage to the sliding hip screw (FAITH Investigators 2017, The Lancet — international, multicentre, randomised, 81 centres, 8 countries)
Study: Randomized controlled trial (international, multicentre)
Population: 1,108 patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation, randomised to a sliding hip screw (n = 557) or multiple cancellous screws (n = 551); primary analysis 542 vs 537 patients; surgeons and patients unblinded, data analyst blinded; primary outcome hip reoperation within 24 months.
Summary: FAITH trial: reoperation 20% vs 22% at 24 months — no advantage to the sliding hip screw (FAITH Investigators 2017, The Lancet — international, multicentre, randomised, 81 centres, 8 countries)
Result: Reoperations within 24 months did not differ: 107 (20%) of 542 in the sliding hip screw group versus 117 (22%) of 537 in the cancellous screws group (hazard ratio 0.83, 95% CI 0.63 to 1.09; p = 0.18). Avascular necrosis was more common with the sliding hip screw (50 patients [9%] vs 28 patients [5%]; HR 1.91, 95% CI 1.06 to 3.44; p = 0.0319). Medically related adverse events did not differ between groups (p = 0.82). The authors note smokers and patients with displaced or base-of-neck fractures might do better with a sliding hip screw — a subgroup reading, not the trial's primary result.
Watch out: FAITH enrolled fractures judged suitable for fixation; its result does not answer fixation versus joint replacement, which is a different shelf's question. The avascular-necrosis excess was a secondary outcome and was not confirmed in the pooled analysis carded below.
Source: FAITH Investigators. Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial. Lancet (London, England). 2017. PMID: 28262269. Registry ID: NCT00761813. MeSH: Aged · Aged, 80 and over · Bone Screws · Equipment Design · Female · Femoral Neck Fractures/surgery · Femur Head Necrosis/etiology · Fracture Fixation, Internal/adverse effects,instrumentation,methods · Fracture Healing · Humans · Kaplan-Meier Estimate · Male · Quality of Life · Reoperation/statistics & numerical data · Single-Blind Method · Treatment Outcome
Card 2 — Meta-analysis of 10 randomised trials (1,934 patients): no difference in reoperation, nonunion, avascular necrosis or mortality — only more blood loss with the sliding hip screw (Shehata 2019, European Journal of Orthopaedic Surgery & Traumatology)
Study: Systematic review and meta-analysis of randomized controlled trials
Population: 10 randomised trials directly comparing sliding hip screw with cancellous screws for femoral neck fractures in adults, 1,934 patients in total; the set overlaps the FAITH trial carded above, so these patients are not additional to FAITH's 1,108.
Summary: Meta-analysis of 10 randomised trials (1,934 patients): no difference in reoperation, nonunion, avascular necrosis or mortality — only more blood loss with the sliding hip screw (Shehata 2019, European Journal of Orthopaedic Surgery & Traumatology)
Result: No significant difference between the implants in operative time, postoperative hip function, nonunion, avascular necrosis, reoperation rate, infection, fracture healing, hip pain, medical complications or mortality. The sliding hip screw group had more intraoperative blood loss (mean difference 110.01 mL, 95% CI 52.42 to 167.60; p = 0.00002).
Watch out: The pooled set includes FAITH, so this card adds consistency across the smaller earlier trials, not independent patients; the avascular-necrosis signal seen in FAITH alone disappears in the pool.
Source: Shehata MSA et al. Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2019. PMID: 31165917. Registry ID: none in the record. MeSH: Blood Loss, Surgical · Bone Screws · Femoral Neck Fractures/physiopathology,surgery · Femur Head Necrosis/etiology · Fracture Fixation, Internal/instrumentation,methods · Fractures, Ununited/etiology · Hip Joint/physiopathology · Humans · Operative Time · Randomized Controlled Trials as Topic · Reoperation · Treatment Outcome
Card 3 — Synthesis — POSSIBLE (the treatment made no difference): one large trial and the pooled trials agree on reoperation
Study: Synthesis
Population: 1 individually carded trial (FAITH, 1,108 randomised) and 1 meta-analysis of 10 randomised trials (1,934 patients, overlapping FAITH). No combined total is printed because the sets overlap.
Summary: Synthesis — POSSIBLE (the treatment made no difference): one large trial and the pooled trials agree on reoperation
Result: Across FAITH and the pooled randomised evidence, neither implant reduced reoperations, nonunion or mortality. The sliding hip screw costs more intraoperative blood loss, and FAITH's higher avascular-necrosis rate with it (9% vs 5%) was not reproduced in the pool. Subgroup hints in FAITH (smokers, displaced or base-of-neck fractures) remain hypotheses.
Watch out: Both sources compare implants within fixation; neither bears on whether a given fracture should be fixed or replaced.
Source: Synthesis of the reports carded above; no additional source.