SourceMed · Shelf #9119 in the ask interface
Advanced great-toe arthritis (hallux rigidus): a synthetic cartilage implant matched joint fusion on pain, function and the trial's composite success endpoint at 2 years — 9.2% of implants were removed and converted to fusion
Shelf #9119 · Bones & joints
POSSIBLE (benefit) — 1 randomised non-inferiority trial (236 enrolled, 202 randomised: 152 implant, 50 fusion): the composite primary endpoint (pain improvement, maintained function, no major safety event) showed statistical equivalence between the implant and fusion; pain and function scores improved significantly in both groups at 12 and 24 months; secondary surgery 11.2% vs 12.0%, with 14 implants (9.2%) removed and converted to fusion by 2 years. Single-trial shelf — Tier C by rule. The trial reports do not name a brand or manufacturer for the implant in their records, so none is named here.
Stamped: 2026-11-28.
Evidence published: 2016–2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with advanced hallux rigidus (grade 2–4), does a synthetic cartilage implant (hemiarthroplasty of the first metatarsophalangeal joint) give pain relief and function equivalent to arthrodesis (fusion), while preserving toe motion?
Balance of the evidence
POSSIBLE (benefit) — 1 randomised non-inferiority trial (236 enrolled, 202 randomised: 152 implant, 50 fusion): the composite primary endpoint (pain improvement, maintained function, no major safety event) showed statistical equivalence between the implant and fusion; pain and function scores improved significantly in both groups at 12 and 24 months; secondary surgery 11.2% vs 12.0%, with 14 implants (9.2%) removed and converted to fusion by 2 years. Single-trial shelf — Tier C by rule. The trial reports do not name a brand or manufacturer for the implant in their records, so none is named here. Composition: one trial, reported twice — the 2017 paper is a patient-factor analysis of the same patients and adds no one. The implant's claim is equivalence to fusion plus preserved motion (active dorsiflexion improved 6.2 degrees and was maintained at 24 months), not superiority. POSSIBLE: a motion-preserving implant matched the fusion standard at 2 years in the single trial that tested it, with about 1 in 11 implants already converted to fusion.
MeSH: Adult · Aged · Arthrodesis/methods · Cartilage · Hallux Rigidus/surgery · Humans · Joint Prosthesis · Metatarsophalangeal Joint/surgery · Middle Aged · Pain/surgery · Prospective Studies · Prostheses and Implants · Prosthesis Design · Reoperation
Cards (3)
Card 1 — MOTION trial: implant statistically equivalent to fusion on the composite endpoint; both groups' pain and function improved; 9.2% of implants converted to fusion by 2 years (Baumhauer 2016, Foot & Ankle International — prospective randomised non-inferiority trial, 12 centres, Canada and UK)
Study: Randomized controlled trial (non-inferiority, multicentre)
Population: 236 patients with advanced-stage hallux rigidus enrolled; after withdrawals and nonrandomised training cases, 202 randomised 2:1 — 152 to the synthetic cartilage implant (a small 8/10 mm hydrogel implant; the record names no brand or manufacturer) and 50 to first metatarsophalangeal arthrodesis. Primary endpoint a composite of pain (≥30% improvement in visual analogue scale pain at 12 months), function (Foot and Ankle Ability Measure sports subscore maintained at 12 months) and safety (no major safety event at 2 years); non-inferiority margin 15%.
Summary: MOTION trial: implant statistically equivalent to fusion on the composite endpoint; both groups' pain and function improved; 9.2% of implants converted to fusion by 2 years (Baumhauer 2016, Foot & Ankle International — prospective randomised non-inferiority trial, 12 centres, Canada and UK)
Result: Visual analogue pain scores decreased significantly in both groups at 12 and 24 months, and Foot and Ankle Ability Measure sports and activities-of-daily-living subscores improved significantly at both time points in both groups. First metatarsophalangeal active dorsiflexion improved 6.2 degrees (27.3%) after implant placement and was maintained at 24 months. Secondary surgeries occurred in 17 (11.2%) implant patients and 6 (12.0%) arthrodesis patients; 14 (9.2%) implants were removed and converted to arthrodesis, and 6 (12.0%) arthrodesis patients had hardware removal. There were no cases of implant fragmentation, wear or bone loss. On the composite primary endpoint, in both intention-to-treat and modified intention-to-treat analyses, the implant was statistically equivalent to arthrodesis.
Watch out: Equivalence was declared against a 15% non-inferiority margin on a composite endpoint — a generous margin — and follow-up is 2 years for a permanent implant whose failure mode (conversion to fusion) had already claimed 9.2% by then. The 2:1 allocation leaves only 50 fusion patients.
Source: Baumhauer JF et al. Prospective, Randomized, Multi-centered Clinical Trial Assessing Safety and Efficacy of a Synthetic Cartilage Implant Versus First Metatarsophalangeal Arthrodesis in Advanced Hallux Rigidus. Foot & ankle international. 2016. PMID: 26922669. Registry ID: none in the record. MeSH: Adult · Aged · Arthrodesis/methods · Cartilage · Hallux Rigidus/surgery · Humans · Joint Prosthesis · Metatarsophalangeal Joint/surgery · Middle Aged · Pain/surgery · Prospective Studies · Prostheses and Implants · Prosthesis Design · Reoperation
Card 2 — Same trial, patient-factor analysis: success did not vary by arthritis grade, age, BMI, symptom duration or preoperative stiffness (Goldberg 2017, Foot & Ankle International — companion report of the MOTION trial)
Study: Randomized controlled trial (same trial as the card above — companion analysis)
Population: The same trial's patients — final outcome data for 129 implant hemiarthroplasties and 47 arthrodeses (a subset of the 202 randomised) — counted once in this shelf's total; clinical success defined by the same composite criteria at 24 months.
Summary: Same trial, patient-factor analysis: success did not vary by arthritis grade, age, BMI, symptom duration or preoperative stiffness (Goldberg 2017, Foot & Ankle International — companion report of the MOTION trial)
Result: Success rates for implant and arthrodesis were similar (P > .05) when stratified by hallux rigidus grade (2, 3 or 4), gender, age, body mass index, symptom duration, prior first metatarsophalangeal surgery, and preoperative pain, hallux valgus angle and range of motion. The authors conclude the implant was appropriate across grades 2–4, including in patients with mild hallux valgus (≤20 degrees) or substantial preoperative stiffness.
Watch out: Same-trial companion report: subgroup equivalence in a 202-patient trial is a low-power statement — absence of a detected interaction, not proof that no subgroup does worse.
Source: Goldberg A et al. Association Between Patient Factors and Outcome of Synthetic Cartilage Implant Hemiarthroplasty vs First Metatarsophalangeal Joint Arthrodesis in Advanced Hallux Rigidus. Foot & ankle international. 2017. PMID: 28820949. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Arthrodesis/methods · Female · Follow-Up Studies · Hallux Rigidus/diagnosis,surgery · Hemiarthroplasty/methods · Humans · Joint Prosthesis · Male · Metatarsophalangeal Joint/physiopathology,surgery · Middle Aged · Pain Measurement · Patient Selection · Prospective Studies · Prosthesis Design · Range of Motion, Articular/physiology · Risk Assessment · Severity of Illness Index · Sex Factors · Statistics, Nonparametric · Time Factors · Treatment Outcome
Card 3 — Synthesis — POSSIBLE (benefit): equivalence to fusion at 2 years, from one trial, with a 1-in-11 early conversion rate
Study: Synthesis
Population: 1 trial: 236 enrolled, 202 randomised (152 implant, 50 fusion), reported in 2 papers counted once. Total documented N = 202 randomised.
Summary: Synthesis — POSSIBLE (benefit): equivalence to fusion at 2 years, from one trial, with a 1-in-11 early conversion rate
Result: For advanced hallux rigidus, the synthetic cartilage implant matched fusion on pain, function and the trial's composite success definition at 2 years while preserving about 6 degrees more dorsiflexion — and about 1 in 11 implants had already been removed and fused by 2 years, the same reoperation burden as fusion's hardware removals. Whether the implant's motion advantage survives a decade is exactly what this single 2-year trial cannot say.
Watch out: Single-trial shelf. The trial reports carded here do not name the implant's brand or manufacturer, so this shelf does not either; products now sold for this indication may differ from the tested implant.
Source: Synthesis of the reports carded above; no additional source.