SourceMed · Shelf #9122 in the ask interface
Ankle fractures: fixing the fibula with an intramedullary nail instead of a plate gave equal ankle function, fewer infections — and more hardware failures in the randomised-trial pool (7 trials, 586 patients)
Shelf #9122 · Bones & joints
SPLIT — by outcome: function scores did not differ at 3, 6 or 12 months in the randomised-trial meta-analysis (7 trials, 586 patients) or in either individually carded trial; infection favoured the nail (risk ratio 0.23, 95% CI 0.11 to 0.47) while hardware failure favoured the plate (risk ratio 2.05, 1.16 to 3.60); union did not differ.
Stamped: 2026-11-28.
Evidence published: 2014–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with an ankle fracture needing fibular fixation, does an intramedullary fibular nail give function, union and complications equivalent to plate fixation?
Balance of the evidence
SPLIT — by outcome: function scores did not differ at 3, 6 or 12 months in the randomised-trial meta-analysis (7 trials, 586 patients) or in either individually carded trial; infection favoured the nail (risk ratio 0.23, 95% CI 0.11 to 0.47) while hardware failure favoured the plate (risk ratio 2.05, 1.16 to 3.60); union did not differ. Composition: 1 meta-analysis of 7 randomised trials (586 patients) plus 2 individually carded trials that fall within that pool — no combined total is printed. One carded trial (Asloum 2014) found better function scores with the nail (Kitaoka 96 vs 82; Olerud-Molander 97 vs 83), against the pool's tie; it used one named implant, the Epifisa FH intramedullary nail (the record gives the implant name only and does not name a company, so none is stated here). SPLIT: the nail trades the plate's wound problems for its own hardware-failure problem, at equal function.
MeSH: Humans · Ankle Fractures/surgery · Bone Plates · Fracture Fixation, Intramedullary/methods,instrumentation · Bone Nails · Randomized Controlled Trials as Topic · Adult · Fibula/injuries,surgery · Treatment Outcome
Cards (4)
Card 1 — Randomised-trial meta-analysis (7 trials, 586 patients): function equal at 3, 6 and 12 months; infection risk ratio 0.23 for the nail, hardware failure risk ratio 2.05 against it (Zhang 2024, Journal of Orthopaedic Surgery and Research)
Study: Systematic review and meta-analysis of randomized controlled trials
Population: 7 randomised controlled trials, 586 adults with ankle fractures, comparing fibular intramedullary nail fixation with plate fixation of the fibula.
Summary: Randomised-trial meta-analysis (7 trials, 586 patients): function equal at 3, 6 and 12 months; infection risk ratio 0.23 for the nail, hardware failure risk ratio 2.05 against it (Zhang 2024, Journal of Orthopaedic Surgery and Research)
Result: No statistically significant differences in functional outcomes between the groups at 3, 6 or 12 months postoperatively. The nail group had a lower infection rate (risk ratio 0.23, 95% CI 0.11 to 0.47; P < 0.0001). The plate group had the lower hardware failure rate (risk ratio for the nail 2.05, 95% CI 1.16 to 3.60; P = 0.01), with the hardware-failure difference larger in European studies (RR 2.74, 1.45 to 5.18) and in older adults (RR 4.25, 1.57 to 11.50). The authors call for larger multicentre randomised trials.
Watch out: Seven small trials (586 patients in total) using different nail designs; the hardware-failure signal is driven by subgroups (Europe, older adults), which is also where the nail is most often chosen for poor soft tissues.
Source: Zhang J et al. The fibular intramedullary nail versus plate fixation for ankle fractures in adults: a systematic review and meta-analysis of randomized controlled trials. Journal of orthopaedic surgery and research. 2024. PMID: 39238000. Registry ID: none in the record. MeSH: Humans · Ankle Fractures/surgery · Bone Plates · Fracture Fixation, Intramedullary/methods,instrumentation · Bone Nails · Randomized Controlled Trials as Topic · Adult · Fibula/injuries,surgery · Treatment Outcome
Card 2 — The largest early trial: union equal, complications 7% with the nail vs 56% with the plate, function scores better with the nail (Asloum 2014, Orthopaedics & Traumatology: Surgery & Research — prospective randomised trial)
Study: Randomized controlled trial
Population: 71 patients (mean age 53 ± 19) with closed isolated displaced lateral malleolus fractures or bi-/trimalleolar fractures, randomised to plate fixation (n = 35) or the Epifisa FH intramedullary nail (n = 36) — the record names the implant but not its manufacturer; in 7 cases nailing proved technically impossible and was converted to plating; after 2 deaths and 2 losses, the final comparative series was 32 plate and 28 nail patients, followed 1 year.
Summary: The largest early trial: union equal, complications 7% with the nail vs 56% with the plate, function scores better with the nail (Asloum 2014, Orthopaedics & Traumatology: Surgery & Research — prospective randomised trial)
Result: Union did not differ between the fixations (P = 0.5605). Complications were significantly fewer with nailing (7% versus 56%), and functional scores at 1 year were better with the nail (Kitaoka 96 versus 82; Olerud-Molander 97 versus 83). The authors restrict their conclusion to non-comminuted ankle fractures without syndesmotic injury.
Watch out: The 56% plate complication rate is far above the pooled literature and the analysed set shrank from 71 randomised to 60 compared, with the 7 failed nailings analysed separately — this trial's function advantage for the nail was not reproduced in the randomised pool carded above.
Source: Asloum Y et al. Internal fixation of the fibula in ankle fractures: a prospective, randomized and comparative study: plating versus nailing. Orthopaedics & traumatology, surgery & research : OTSR. 2014. PMID: 24709304. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Ankle Fractures/diagnostic imaging,surgery · Bone Nails · Bone Plates · Female · Fibula/diagnostic imaging,surgery · Follow-Up Studies · Fracture Fixation, Internal/instrumentation,methods · Fracture Fixation, Intramedullary/instrumentation,methods · Fractures, Malunited/epidemiology · Humans · Incidence · Male · Middle Aged · Postoperative Complications/epidemiology · Prospective Studies · Radiography · Single-Blind Method · Treatment Outcome
Card 3 — Second carded trial: function and patient-reported scores indistinguishable; smaller scar and less screening time with the nail; the only deep infection was in the plate group (Badenhorst 2020, International Orthopaedics — prospective randomised trial)
Study: Randomized controlled trial
Population: Adults with unstable ankle fractures randomised (November 2013 to December 2016) to anatomically contoured fibular plate-and-screw fixation or fibula nail fixation; outcomes included the Olerud-Molander score, Grimby score, swelling, and ankle movements; the record does not state the number randomised (N not documented in the record).
Summary: Second carded trial: function and patient-reported scores indistinguishable; smaller scar and less screening time with the nail; the only deep infection was in the plate group (Badenhorst 2020, International Orthopaedics — prospective randomised trial)
Result: No differences were observed in functional or patient-reported outcome measures between the groups. Scar size (p < 0.001) and screening (fluoroscopy) time (p < 0.001) differed significantly, favouring the nail. One deep infection occurred in the plate group and none in the nail group (not statistically significant). The authors conclude both methods yield very similar functional results.
Watch out: With its sample size not documented in the record, this trial's weight cannot be judged from its record; it is carded for its concordant function result and its scar/screening-time findings.
Source: Badenhorst D et al. Intramedullary fixation versus anatomically contoured plating of unstable ankle fractures: a randomized control trial. International orthopaedics. 2020. PMID: 31980861. Registry ID: none in the record. MeSH: Adult · Ankle Fractures/diagnostic imaging,surgery · Ankle Joint/diagnostic imaging,surgery · Bone Plates · Bone Screws · Female · Fibula/diagnostic imaging,surgery · Fracture Fixation, Internal/methods · Fracture Fixation, Intramedullary/methods · Humans · Male · Middle Aged · Patient Reported Outcome Measures · Prospective Studies · Treatment Outcome
Card 4 — Synthesis — SPLIT by outcome: equal function and union; infection and hardware failure pull opposite ways
Study: Synthesis
Population: 1 meta-analysis of 7 randomised trials (586 patients) and 2 individually carded trials within that pool (Asloum: 71 randomised; Badenhorst: N not documented in the record). No combined total is printed because the carded trials are inside the pool.
Summary: Synthesis — SPLIT by outcome: equal function and union; infection and hardware failure pull opposite ways
Result: Across the randomised evidence, how the fibula is fixed does not change ankle function or union. The nail's smaller wounds come with about a quarter of the plate's infection risk (risk ratio 0.23) but about double the hardware failure risk (risk ratio 2.05), the failure excess concentrated in older adults — the very patients most often offered the nail. One early trial's large function advantage for the nail stands against the pool and is not the basis of this stamp.
Watch out: Nail designs differ across the trials (one carded trial names its implant, the Epifisa FH nail, without naming a manufacturer in the record); pooled results average across devices, and current products may differ from those tested.
Source: Synthesis of the reports carded above; no additional source.