SourceMed · Shelf #9138 in the ask interface

Artificial-intelligence ECG for left ventricular systolic dysfunction — 1 meta-analysis (17 studies pooled sensitivity 0.87 / specificity 0.84) plus the derivation study and two external validations: discrimination is strong in clinic populations (AUC 0.93) but the derivation cut-off collapsed to sensitivity 0.27 in a population sample where only 0.6% had the condition

Shelf #9138 · Heart, vessels, blood pressure & clotting

PREDICTIVE PERFORMANCE — strong discrimination in enriched clinic populations, cut-off not portable to low-prevalence screening: the meta-analysis (17 studies) pooled sensitivity 0.87 and specificity 0.84 for AI-enabled ECG detection of left ventricular systolic dysfunction; the derivation network scored AUC 0.93 with sensitivity 86.3% / specificity 85.7% on its own institution's test set (ejection fraction ≤35%), but in an external population sample (n = 4,277; prevalence 0.6% versus 7.8% in derivation) the same probability cut-off gave sensitivity 26.9% / specificity 97.4% (AUC 0.82) — the ranking survives the journey, the threshold does not

Stamped: 2026-11-28.

Evidence published: 2019–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does an artificial-intelligence algorithm applied to a standard 12-lead electrocardiogram (AI-ECG) detect left ventricular systolic dysfunction against echocardiography — in the populations it was trained on, and when it is carried to external populations with much lower prevalence?

Balance of the evidence

PREDICTIVE PERFORMANCE — strong discrimination in enriched clinic populations, cut-off not portable — composition: 1 systematic review and meta-analysis (17 studies in the meta-analysis), the derivation study, and 2 external validation studies (one population-based, one multicentre image-based). The pooled estimate across models and thresholds is sensitivity 0.87 / specificity 0.84 (labelled in words at first occurrence), best for severe dysfunction (ejection fraction threshold 35%) and weaker for mild. The derivation network (44,959 patients trained; 52,870 tested) reached AUC 0.93. Carried to a Russian population sample where prevalence was 0.6% rather than 7.8%, AUC held up at 0.82 but the imported cut-off's sensitivity fell to 26.9% while specificity rose to 97.4% — at that prevalence almost all positives the cut-off was tuned to catch are absent, and almost all it flags are false. An image-based model (reading photographs of ECG printouts) held AUCs of 0.90–0.95 across five external sites, the base's most portable result. PROPOSED PREDICTIVE PERFORMANCE: AI-ECG is a genuine risk-ranking signal for ventricular dysfunction, including a 4-fold higher future-dysfunction risk in screen-positive people with normal ejection fraction — but any deployment needs a locally calibrated cut-off and a confirmatory echocardiogram; a positive or negative at an imported threshold is not a diagnosis.

MeSH: Adult · Aged · Aged, 80 and over · Artificial Intelligence · Electrocardiography · Female · Heart/physiopathology · Humans · Male · Mass Screening · Middle Aged · Myocardial Contraction · Neural Networks, Computer · ROC Curve · Sensitivity and Specificity · Stroke Volume

Cards (5)

Card 1 — Meta-analysis: pooled sensitivity 0.87 and specificity 0.84 across 17 studies, best at the 35% ejection-fraction threshold (R 2025, Biomedical Engineering Letters — systematic review and meta-analysis)

Study: Systematic review and meta-analysis (19 studies reviewed; 17 meta-analysed)

Population: 19 studies of AI-enabled ECG for detection of left ventricular systolic dysfunction qualified for the systematic review and 17 for the meta-analysis, with study quality assessed by QUADAS-2; ejection-fraction thresholds varied between studies (35%, 40% and 50% thresholds all represented).

Summary: Meta-analysis: pooled sensitivity 0.87 and specificity 0.84 across 17 studies, best at the 35% ejection-fraction threshold (R 2025, Biomedical Engineering Letters — systematic review and meta-analysis)

Result: The pooled sensitivity and specificity for AI-enabled ECG models were 86.9% and 84.4% respectively (sensitivity 0.87 / specificity 0.84, labelled in words at first occurrence). Studies using an ejection fraction threshold of 35% had the highest sensitivity, while those using 50% showed lower sensitivity and specificity. Externally validated studies showed a strong positive Spearman correlation (ρ = 0.696, p = 0.008), indicating a threshold effect, and the hierarchical summary curve showed diagnostic robustness at the 40% threshold but a lack of real-world generalisability for test-only studies. The authors conclude the models show strong diagnostic potential for severe dysfunction but remain limited for mild cases, and that external validation is essential.

Watch out: A pooled estimate across different networks, thresholds and populations — it averages exactly the portability problem the validation cards below expose, so it is carded as the field's centre of mass, not as any one product's performance. The record carries no MeSH terms (printed 'none in the record' on this card).

Source: R R G et al. Artificial intelligence in ECG-based diagnosis of low left ventricular ejection fraction: a systematic review and meta-analysis. Biomedical engineering letters. 2025. PMID: 40625551. Registry ID: none in the record. MeSH: none in the record

Card 2 — Derivation: AUC 0.93, sensitivity 86.3% / specificity 85.7% on the home test set, and screen-positive patients had 4 times the future risk (Attia 2019, Nature Medicine — Mayo Clinic, 44,959 trained / 52,870 tested)

Study: Algorithm derivation and internal test-set validation (single centre)

Population: Paired 12-lead ECG and echocardiogram data from 44,959 patients at a single academic centre were used to train a convolutional neural network to identify ventricular dysfunction (ejection fraction ≤35%) from the ECG alone; performance was measured on an independent test set of 52,870 patients from the same institution, where the prevalence of dysfunction was 7.8%.

Summary: Derivation: AUC 0.93, sensitivity 86.3% / specificity 85.7% on the home test set, and screen-positive patients had 4 times the future risk (Attia 2019, Nature Medicine — Mayo Clinic, 44,959 trained / 52,870 tested)

Result: On the test set the network yielded AUC 0.93, sensitivity 86.3%, specificity 85.7% and accuracy 85.7% (sensitivity 0.86 / specificity 0.86 in the labelled form used on this shelf). In patients without ventricular dysfunction, those with a positive AI screen were at 4 times the risk of developing future ventricular dysfunction compared with those with a negative screen (hazard ratio 4.1; 95% CI 3.3 to 5.0). The authors propose the ECG as a screening tool for asymptomatic left ventricular dysfunction.

Watch out: Internal validation at the deriving institution, in a clinic population with 7.8% prevalence — the next card shows what the same algorithm's cut-off does where prevalence is 0.6%. The 4-fold future-risk figure makes a 'false positive' partly a pre-clinical signal, which cuts both ways: it is prognostic information, not present dysfunction.

Source: Attia ZI et al. Screening for cardiac contractile dysfunction using an artificial intelligence-enabled electrocardiogram. Nature medicine. 2019. PMID: 30617318. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Artificial Intelligence · Electrocardiography · Female · Heart/physiopathology · Humans · Male · Mass Screening · Middle Aged · Myocardial Contraction · Neural Networks, Computer · ROC Curve · Sensitivity and Specificity · Stroke Volume

Card 3 — External validation in a population sample: AUC held at 0.82, but the imported cut-off's sensitivity collapsed to 26.9% (Attia 2021, International Journal of Cardiology — Know Your Heart Study, Russia, n = 4,277)

Study: External validation study (population-based; n = 4,277)

Population: 4,277 adults aged 35–69 years from two Russian cities in a population-based cross-sectional study, all with ECG and transthoracic echocardiography; left ventricular systolic dysfunction defined as ejection fraction ≤35%; the Mayo-derived algorithm applied unchanged, including its derivation-study probability cut-off of 0.256. Prevalence of dysfunction was 0.6%, versus 7.8% in the derivation study.

Summary: External validation in a population sample: AUC held at 0.82, but the imported cut-off's sensitivity collapsed to 26.9% (Attia 2021, International Journal of Cardiology — Know Your Heart Study, Russia, n = 4,277)

Result: Overall discrimination remained robust (AUC 0.82), but at the imported cut-off of 0.256 the sensitivity, specificity and accuracy were 26.9%, 97.4% and 97.0% respectively (sensitivity 0.27 / specificity 0.97, labelled in words). Other cut-offs were analysed for different sensitivity values. The authors conclude the algorithm detects dysfunction with robust test performance in a very different population, but that population-specific cut-offs may be necessary for clinical implementation, and that differences in population characteristics and in ECG and echocardiographic data quality may affect performance.

Watch out: Only about 26 participants had the condition (0.6% of 4,277), so the sensitivity estimate rests on very few cases — the robust findings are the AUC's survival and the cut-off's failure, which are two different properties of the same model.

Source: Attia IZ et al. External validation of a deep learning electrocardiogram algorithm to detect ventricular dysfunction. International journal of cardiology. 2021. PMID: 33400971. Registry ID: none in the record. MeSH: Adult · Aged · Cross-Sectional Studies · Deep Learning · Electrocardiography · Humans · Middle Aged · Russia · Stroke Volume · Ventricular Dysfunction, Left/diagnostic imaging,epidemiology · Ventricular Function, Left

Card 4 — Reading the printout, not the signal: an image-based model held AUC 0.90–0.95 across five external sites (Sangha 2023, Circulation — ECG-image model, 385,601 ECGs in development)

Study: Algorithm development with multicentre external validation (image-based)

Population: A convolutional neural network trained on 385,601 ECGs with paired echocardiograms from one US health system (2015–2021) to detect ejection fraction <40% from ECG images — the plotted 12-lead traces in multiple formats — then validated internally, at four external US sites, in outpatient clinics, and prospectively in the Brazilian Longitudinal Study of Adult Health.

Summary: Reading the printout, not the signal: an image-based model held AUC 0.90–0.95 across five external sites (Sangha 2023, Circulation — ECG-image model, 385,601 ECGs in development)

Result: Discrimination was high across formats and sites: internal validation AUC 0.91; external AUCs of 0.90 (Cedars Sinai), 0.94 (outpatient clinics), 0.90, 0.91 and 0.90 (three further hospital sites) and 0.95 in the Brazilian cohort, with areas under the precision-recall curve from 0.45 to 0.88 depending on prevalence. An ECG image suggestive of dysfunction carried 27.5-fold higher odds of dysfunction on echocardiography (95% CI 22.3 to 33.9) in the held-out set, and a positive screen in people with ejection fraction ≥40% was associated with a 3.9-fold increased risk of future dysfunction (hazard ratio 3.9; 95% CI 3.3 to 4.7; median follow-up 3.2 years). No sensitivity/specificity pair at a fixed cut-off is printed in the record, and none is quoted on this shelf.

Watch out: AUCs travel better than thresholds: this study reports discrimination and odds, not an operating point, so it supports the ranking claim and cannot by itself set a screening cut-off. Development data came from a single health system.

Source: Sangha V et al. Detection of Left Ventricular Systolic Dysfunction From Electrocardiographic Images. Circulation. 2023. PMID: 37489538. Registry ID: none in the record. MeSH: Adult · Humans · Prospective Studies · Longitudinal Studies · Electrocardiography · Ventricular Dysfunction, Left/diagnostic imaging · Ventricular Function, Left/physiology

Card 5 — Synthesis — PREDICTIVE PERFORMANCE: the ranking is real and portable, the threshold is not

Study: Synthesis

Population: 1 meta-analysis (17 studies) plus the derivation study (52,870-patient test set) and 2 external validations (n = 4,277 population sample; 385,601-ECG image model with five external sites).

Summary: Synthesis — PREDICTIVE PERFORMANCE: the ranking is real and portable, the threshold is not

Result: Three facts survive every journey on this shelf: the algorithms rank risk well (AUC 0.82–0.95 in every external setting); a positive screen carries prognostic weight even when the echocardiogram is currently normal (hazard ratios 4.1 and 3.9 for future dysfunction); and a cut-off tuned in an enriched clinic population fails in a general population — sensitivity 26.9% at the imported threshold where prevalence was 0.6%. The pooled sensitivity 0.87 / specificity 0.84 (labelled in words) describes the average study, which is neither the derivation clinic nor your screening population. Every positive on every card ends at an echocardiogram. No report was refused.

Watch out: All models on this shelf are research algorithms from academic centres, none is a cleared consumer product, and performance for mild dysfunction (ejection fraction near 50%) is consistently weaker than for severe — a screening programme built on these numbers would find the sickest hearts and miss much of the mild disease.

Source: Synthesis of the reports carded above; no additional source.