SourceMed · Shelf #9155 in the ask interface

Bed alarms and bedside pressure sensors to prevent falls in hospital — 2 randomised trials (documented N = 29,511): falls unchanged in both (risk ratio 1.09 for promoted alarm use; adjusted incidence rate ratio 0.90 for sensors linked to pagers)

Shelf #9155 · Geriatrics, frailty & deprescribing

LIKELY (the treatment made no difference) — 2 randomised trials (documented N = 29,511) each achieved its exposure contrast — alarm use rose from 1.79 to 64.41 days per 1,000 patient-days in one, sensors were fitted and paged staff in the other — and neither reduced falls, fallers, injurious falls or time to first fall.

Stamped: 2026-11-28.

Evidence published: 2012–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In hospital inpatients, do bed alarms — promoted to staff, or as bed and bedside-chair pressure sensors linked to radio-pagers — reduce falls compared with usual care?

Balance of the evidence

LIKELY (the treatment made no difference) — bed alarms and bedside sensors have been tested properly, the devices were actually used, and falls did not fall. Composition: Shorr 2012, a pair-matched cluster-randomised trial in 16 nursing units of one US hospital (27,672 inpatients), and Sahota 2014 (REFINE), an individually randomised trial in acute medical wards of one UK teaching hospital (1,839 participants). Documented N = 29,511. Shorr: promoting alarm use raised it from 1.79 to 64.41 days per 1,000 patient-days (P =.004), yet the change in fall rate did not differ between arms (risk ratio 1.09; 95% CI 0.85–1.53), nor did fallers, injurious falls or restraint use. Sahota: bedside falls were 8.71 per 1,000 bed days with sensors versus 9.84 per 1,000 bed days with standard care (adjusted incidence rate ratio 0.90; 95% CI 0.66–1.22; P =.51), time to first fall did not differ (adjusted HR 0.95; 95% CI 0.67–1.34), and the sensor strategy cost more (£7,199 vs £6,400 per patient) with no quality-of-life gain (mean QALY difference 0.0001). LIKELY (the treatment made no difference): two independent randomised designs agree that alerting staff to a patient leaving the bed does not, by itself, prevent falls.

MeSH: Accidental Falls/*prevention & control · Beds · Clinical Alarms/*statistics & numerical data · Hospital Units · Hospitals, University · Hospitals, Urban · Humans · *Inpatients · Matched-Pair Analysis · Outcome Assessment, Health Care · Restraint, Physical/statistics & numerical data · Tennessee

Cards (3)

Card 1 — Promoting bed alarm use: alarm use rose 36-fold, falls did not change (Shorr 2012, Annals of Internal Medicine — cluster RCT, 16 units, 27,672 inpatients): risk ratio for change in fall rate 1.09

Study: Cluster randomised controlled trial (16 nursing units)

Population: 27,672 inpatients on 16 general medical, surgical and specialty nursing units of an urban US community hospital over 18 months. Intervention units received education, training and technical support to promote a standard bed alarm system; on control units alarms were available but not promoted. The record names no alarm brand or manufacturer, so none is stated here.

Summary: Promoting bed alarm use: alarm use rose 36-fold, falls did not change (Shorr 2012, Annals of Internal Medicine — cluster RCT, 16 units, 27,672 inpatients): risk ratio for change in fall rate 1.09

Result: Alarm use was 64.41 days per 1,000 patient-days on intervention units versus 1.79 days per 1,000 patient-days on control units (P = .004). There was no difference in the change in falls per 1,000 patient-days (risk ratio 1.09; 95% CI 0.85–1.53), nor in the number of patients who fell, injurious fall rates, or the number of patients physically restrained.

Watch out: This trial tests promoting alarm use, not alarms versus no alarms — control units could still use alarms, though in practice they rarely did (1.79 days per 1,000 patient-days). It was conducted at a single site and, by its authors' account, was slightly underpowered compared with the initial design.

Source: Shorr RI et al. Effects of an intervention to increase bed alarm use to prevent falls in hospitalized patients: a cluster randomized trial. Annals of Internal Medicine. 2012. PMID: 23165660. Registry ID: NCT00183053. MeSH: Accidental Falls/*prevention & control · Beds · Clinical Alarms/*statistics & numerical data · Hospital Units · Hospitals, University · Hospitals, Urban · Humans · *Inpatients · Matched-Pair Analysis · Outcome Assessment, Health Care · Restraint, Physical/statistics & numerical data · Tennessee

Card 2 — REFINE: bed and chair pressure sensors linked to pagers — bedside falls 8.71 vs 9.84 per 1,000 bed days, not significant, and not cost-effective (Sahota 2014, Age and Ageing — RCT, 1,839 patients)

Study: Randomised controlled trial (individual, 1 hospital)

Population: 1,839 patients (918 intervention, 921 control) admitted to acute general medical wards of a large UK teaching hospital. The intervention fitted bed and bedside-chair pressure sensors linked to radio-pagers carried by staff; the control group received standard care. The record names no sensor brand or manufacturer, so none is stated here.

Summary: REFINE: bed and chair pressure sensors linked to pagers — bedside falls 8.71 vs 9.84 per 1,000 bed days, not significant, and not cost-effective (Sahota 2014, Age and Ageing — RCT, 1,839 patients)

Result: There were 85 bedside falls (65 fallers) in the intervention group, a rate of 8.71 per 1,000 bed days, versus 83 bedside falls (64 fallers) at 9.84 per 1,000 bed days in the control group (adjusted incidence rate ratio 0.90; 95% CI 0.66–1.22; P = .51). Time to first bedside fall did not differ (adjusted HR 0.95; 95% CI 0.67–1.34; P = .12). Mean cost per patient was £7,199 in the intervention group versus £6,400 in the control group, with a mean QALY difference of 0.0001 (95% CI −0.0006 to 0.0004).

Watch out: A single-intervention strategy on general medical wards: the trial does not test sensors as one component of a wider falls programme. Costs are UK 2014 prices as printed in the record.

Source: Sahota O et al. REFINE (REducing Falls in In-patieNt Elderly) using bed and bedside chair pressure sensors linked to radio-pagers in acute hospital care: a randomised controlled trial. Age and Ageing. 2014. PMID: 24141253. Registry ID: ISRCTN44972300. MeSH: Accidental Falls/economics/*prevention & control · Aged · Aged, 80 and over · *Beds/economics · Cost-Benefit Analysis · England/epidemiology · Equipment Design · Female · Hospital Costs · *Hospitals, Teaching/economics · Humans · Incidence · *Inpatients · Male · Middle Aged · Odds Ratio · Quality-Adjusted Life Years · *Remote Sensing Technology/economics · Risk Factors · Time Factors · *Transducers, Pressure/economics

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Synthesis — LIKELY (the treatment made no difference): two randomised trials, exposure achieved, falls unchanged

Study: Synthesis

Population: 2 randomised trials: Shorr 2012 (27,672 inpatients) and Sahota 2014 (1,839 patients). Documented N = 29,511.

Summary: Synthesis — LIKELY (the treatment made no difference): two randomised trials, exposure achieved, falls unchanged

Result: Promoted bed alarms (risk ratio 1.09 for the change in fall rate) and pager-linked bedside sensors (adjusted incidence rate ratio 0.90) both failed to reduce falls, despite the alarm intervention raising alarm use from 1.79 to 64.41 days per 1,000 patient-days. LIKELY (the treatment made no difference) as a stand-alone falls intervention.

Watch out: Multifactorial and exercise-based hospital falls programmes are homed elsewhere (#3832, #798); this shelf is only the alarm/sensor device strategy on its own, and no card is borrowed from those shelves.

Source: Synthesis of the reports carded above; no additional source.

Estimate type: adjusted estimate, as stated in the card.