Diverting the first 1.5–2 mL of blood cuts blood-culture contamination by about two-thirds relative — 0.22% versus 1.78% with a diversion device, 1.6% versus 5.0% and 2.0% versus 5.0% with a simple tube-order technique — without reducing detection of true bacteraemia
Shelf #9169 · Critical care & sepsis
LIKELY — initial specimen diversion reduces blood-culture contamination by roughly two-thirds relative across three controlled trials (2,630 patients/culture sets): 0.22% versus 1.78% with a commercial diversion device, and 1.6% versus 5.0% and 2.0% versus 5.0% with a no-cost change of tube order — with true bacteraemia detection unchanged in each trial (7.2% versus 7.6%; 3.7% versus 5.4%, neither significant)
Stamped: 2026-11-28.
Evidence published: 2017–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults having blood cultures taken, does diverting and sequestering the first portion of the blood draw (with a commercial device or simply by filling another tube first) reduce culture contamination compared with standard collection, without missing true bloodstream infection?
Balance of the evidence
LIKELY — three controlled trials, documented N = 2,630 (patients or culture sets as each record reports them). Rupp 2017 (904 subjects, 1,808 blood cultures in an academic emergency department) found contamination of 0.22% (2/904) with a commercial initial specimen diversion device versus 1.78% (16/904) with standard practice (P =.001), with true bacteraemia detected in 7.2% versus 7.6% (P =.41); the record names the device only as an 'initial specimen diversion device' and gives no brand or manufacturer. The same effect was then reproduced twice with no device at all, by diverting the first blood into a regular tube before the culture bottles: Lalezari 2020 (756 patients, randomised) found contamination of 1.6% versus 5.0% — a 66% relative reduction (95% CI 17% to 86%) — and Zimmerman 2020 (970 culture sets, randomised) found 2.0% versus 5.0% (P =.01), a 60% relative decrease, with true pathogens in 3.7% versus 5.4% (P =.22). LIKELY: the relative effect is consistent across one device trial and two randomised technique trials, the absolute rates differ because baseline contamination differed (1.78% versus 5.0%), and no trial showed a loss of true-positive detection; the commercial device and the free technique have never been compared head-to-head in these records.
MeSH: Bacteremia/microbiology · Blood Culture/methods* · Blood Specimen Collection/instrumentation*/methods · Costs and Cost Analysis · Emergency Service, Hospital · Enterobacteriaceae/isolation & purification · Equipment Contamination/economics/prevention & control* · Female · Humans · Male · Phlebotomy/instrumentation/methods* · Prospective Studies
Cards (4)
Card 1 — Device trial: contamination 0.22% with the diversion device versus 1.78% with standard collection (Rupp 2017, Clinical Infectious Diseases — prospective controlled trial, 904 subjects, 1,808 blood cultures in an emergency department)
Study: Prospective controlled trial (emergency department)
Population: 904 nonduplicative subjects (971 consented and enrolled) having blood cultures for clinical suspicion of serious infection in an academic centre's emergency department. The device diverts and sequesters the initial 1.5-2 mL portion of blood, which presumably carries contaminating skin cells and microbes; the record calls it an initial specimen diversion device and names no brand or manufacturer. The comparison was standard phlebotomy procedures.
Summary: Device trial: contamination 0.22% with the diversion device versus 1.78% with standard collection (Rupp 2017, Clinical Infectious Diseases — prospective controlled trial, 904 subjects, 1,808 blood cultures in an emergency department)
Result: Blood culture contamination was significantly reduced through use of the initial specimen diversion device compared to standard procedure: 2/904 (0.22%) versus 16/904 (1.78%), P = .001. Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) with the device versus 69/904 (7.6%) with standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. In a Poisson regression model of the department's monthly contamination rate, phlebotomists (who used the device) experienced a significant decrease in contamination while nurses (who did not use the device) did not, and 73% of phlebotomists completing a post-study survey reported widespread user satisfaction.
Watch out: This centre's standard-practice contamination rate (1.78%) was already below the 5% seen in the two technique trials, so the device's absolute gain here (about 1.6 percentage points) is smaller than the relative contrast suggests; the trial was prospective and controlled but is not described in its record as randomised.
Source: Rupp ME et al. Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2017. PMID: 28379370. Registry ID: NCT02102087. MeSH: Bacteremia/microbiology · Blood Culture/methods* · Blood Specimen Collection/instrumentation*/methods · Costs and Cost Analysis · Emergency Service, Hospital · Enterobacteriaceae/isolation & purification · Equipment Contamination/economics/prevention & control* · Female · Humans · Male · Phlebotomy/instrumentation/methods* · Prospective Studies
Card 2 — Randomised technique trial: filling a regular tube first cut contamination from 5.0% to 1.6% — a 66% relative reduction at no additional cost (Lalezari 2020, Clinical Microbiology and Infection — randomised trial, 756 patients)
Study: Randomized controlled trial
Population: 756 adults from whom the treating physician planned to take blood cultures and additional blood chemistry tests, randomised from September 2017 to September 2018 to an initial-specimen diversion technique — changing the order of sampling using regular vacuum specimen tubes instead of commercially available sterile diversion devices — or to the standard procedure in use at the medical centre.
Summary: Randomised technique trial: filling a regular tube first cut contamination from 5.0% to 1.6% — a 66% relative reduction at no additional cost (Lalezari 2020, Clinical Microbiology and Infection — randomised trial, 756 patients)
Result: The technique, compared with the standard procedure, reduced contamination by 66% (95% CI 17%-86%) in relative terms, from 20/400 (5%) with the standard method to 6/356 (1.6%) with the diversion technique, without compromising detection of true bloodstream infection and at no additional cost. Hospital-wide implementation of the technique was associated with a 1.1% saving in hospitalization days. The authors offer the approach as a simple, cost-effective measure to reduce risks to patient safety from contaminated blood cultures, without the need for costly devices.
Watch out: The 66% relative reduction rests on 26 contamination events in total (20 versus 6), hence the wide interval (17% to 86%); the direction is corroborated by the other two trials, but this trial alone could not pin down the size of the effect.
Source: Lalezari A et al. A simplified blood culture sampling protocol for reducing contamination and costs: a randomized controlled trial. Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases. 2020. PMID: 31539635. Registry ID: NCT03088865. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Blood Culture/economics*/methods* · Blood Specimen Collection/economics/instrumentation/methods* · Costs and Cost Analysis* · Female · Hospitals · Humans · Male · Middle Aged · Prospective Studies · Specimen Handling/economics/instrumentation/methods* · Young Adult
Card 3 — Randomised draw-order trial: diverting into a lithium heparin tube first cut contamination from 5.0% to 2.0% (Zimmerman 2020, Clinical Infectious Diseases — randomised trial, 970 culture sets analysed)
Study: Randomized controlled trial
Population: 970 blood culture/biochemistry sets analysed after exclusions, in a trial that randomised the order of blood draws: after standard disinfection and venipuncture, blood was aspirated into a sterile lithium heparin tube before the blood culture bottles (diversion group, 490 sets) or cultures were taken first (control group, 480 sets). All study personnel were blinded except the phlebotomist.
Summary: Randomised draw-order trial: diverting into a lithium heparin tube first cut contamination from 5.0% to 2.0% (Zimmerman 2020, Clinical Infectious Diseases — randomised trial, 970 culture sets analysed)
Result: Contamination occurred in 24 of 480 (5.0%) control versus 10 of 490 (2.0%) diversion group cultures (P = .01) — a 60% relative decrease. True pathogens were identified in 26 of 480 (5.4%) control versus 18 of 490 (3.7%) diversion cultures (P = .22). A post hoc analysis of 637 cultures from 610 medical patients admitted from home, which neutralized demographic differences between the groups, still found contamination more frequent in the control group (17/312 [5%] versus 7/325 [2%]; P = .03). Fewer diversion group patients were admitted to hospital (58.5% versus 66.9%; P = .03) and length of stay was shorter (median 22 versus 30 hours; P = .02). The authors conclude the technique is easy and inexpensive.
Watch out: Despite randomisation, demographic differences appeared between the groups, and the admission and length-of-stay differences are downstream associations a draw-order change cannot plausibly cause directly — the contamination result is the trial's credible finding; the utilisation findings should be read as hypothesis-generating.
Source: Zimmerman FS et al. Modification of Blood Test Draw Order to Reduce Blood Culture Contamination: A Randomized Clinical Trial. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2020. PMID: 31570942. Registry ID: NCT03966534. MeSH: Blood Culture* · Blood Specimen Collection · Equipment Contamination · Hematologic Tests · Humans · Phlebotomy* · Prospective Studies
Card 4 — Synthesis — LIKELY: three controlled trials, one mechanism, contamination down by about two-thirds relative with no loss of true positives
Study: Synthesis
Population: 3 controlled trials: Rupp 2017 (904 subjects), Lalezari 2020 (756 patients), Zimmerman 2020 (970 culture sets). Documented N = 2,630 as reported (subjects in two trials, culture sets in the third).
Summary: Synthesis — LIKELY: three controlled trials, one mechanism, contamination down by about two-thirds relative with no loss of true positives
Result: All three trials diverted the first portion of the draw — the portion carrying skin-plug contaminants — and all three found contamination reduced by roughly 60–66% in relative terms (0.22% versus 1.78%; 1.6% versus 5.0%; 2.0% versus 5.0%), while detection of true bacteraemia or true pathogens did not fall significantly in any trial. The absolute benefit scales with the starting rate: about 3 fewer contaminated cultures per 100 where baseline contamination is 5%, about 1.6 per 100 where it is already 1.78%. Tier C: no — two randomised trials plus a prospective controlled trial, no mortality or single-trial dependence.
Watch out: No trial compared the commercial device against the free tube-order technique, so these records cannot say whether the device buys anything beyond diversion itself; and all three trials come from centres motivated to fix contamination — effects may shrink where baseline technique is already meticulous.
Source: Synthesis of the reports carded above; no additional source.