SourceMed · Shelf #923 in the ask interface
Mandibular advancement devices vs CPAP for obstructive sleep apnea
Shelf #923 · Lungs, breathing & sleep
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2013–2024.
Last source check: 2026-11-09.
Source correction status: no correction or retraction found at the last source check (2026-11-09).
Question
In obstructive sleep apnea, does a mandibular advancement device match CPAP on sleepiness, blood pressure and health outcomes despite lowering the apnea–hypopnoea index less — the Phillips randomised crossover trial and the CRESCENT blood-pressure trial?
Balance of the evidence
LIKELY — for comparable health outcomes, not for equal apnea control, and with no cardiovascular-event claim made on this shelf: Phillips 2013 (126 patients, crossover) found CPAP lowered the apnea–hypopnoea index more (4.5 vs 11.1 events/hour) but patients wore the device longer (6.50 vs 5.20 hours/night), and sleepiness, driving performance and disease-specific quality of life improved similarly on both. CRESCENT (220 randomised patients with hypertension and increased cardiovascular risk) found the device non-inferior to CPAP on 24-hour mean arterial pressure at 6 months (between-group difference −1.6 mm Hg, non-inferiority p<0.001 against a 1.5 mm Hg margin), with the device group's pressure actually falling 2.5 mm Hg while CPAP's did not change. Two randomised trials carry LIKELY for outcome comparability in patients who use the device. Whether treating sleep apnea prevents cardiovascular EVENTS is Shelf #302's question and is not claimed here.
MeSH: Automobile Driving · Blood Pressure Monitoring, Ambulatory/instrumentation · Computer Simulation · Continuous Positive Airway Pressure/instrumentation,methods,statistics & numerical data · Cross-Over Studies · Fatigue/etiology,physiopathology · Hypertension/etiology,physiopathology
Cards (3)
Card 1 — Phillips 2013: CPAP controlled the index better (AHI 4.5 vs 11.1/hour) but the device was worn longer — and sleepiness, driving and quality of life improved the same on both
Study: Randomised crossover trial (1 month of optimal CPAP and 1 month of mandibular advancement device, in random order)
Population: 126 patients with moderate-to-severe obstructive sleep apnea (apnea–hypopnoea index 25.6 [SD 12.3]) randomised to a treatment order; 108 completed both treatments; the abstract does not state mean age or sex mix.
Summary: CPAP vs mandibular device (2013): CPAP controlled the index better (AHI 4.5 vs 11.1/hour ) but the device was worn longer — sleepiness, driving and quality of life were equal.
Result: CPAP was more efficacious at reducing the index (CPAP 4.5 ± 6.6 vs device 11.1 ± 12.1 events/hour; P<0.01) but reported compliance was higher with the device (6.50 ± 1.3 vs 5.20 ± 2 hours per night; P<0.00001). The 24-hour mean arterial pressure was not inferior on the device (CPAP-minus-device difference 0.2 mm Hg [95% CI −0.7 to 1.1]), although neither treatment improved blood pressure overall in this 1-month comparison. Sleepiness, driving simulator performance and disease-specific quality of life improved on both treatments by similar amounts, and the device was superior to CPAP on four general quality-of-life domains.
Watch out: One month per treatment in a crossover: long-term adherence decay, dental and jaw effects of nightly device use, and any outcome beyond surrogate and symptom measures are outside this trial. Its blood-pressure neutrality also tempers CRESCENT's positive reading below — populations differed (CRESCENT required hypertension).
Source: Phillips CL et al. Health outcomes of continuous positive airway pressure versus oral appliance treatment for obstructive sleep apnea: a randomized controlled trial. Am J Respir Crit Care Med. 2013 Apr 15;187(8):879-87. PMID: 23413266. Registry ID: ACTRN12607000289415 (Australian New Zealand Clinical Trials Registry), stated in the record's abstract; the MEDLINE record carries no databank SI field.
Card 2 — CRESCENT 2024: a mandibular device was non-inferior to CPAP for 24-hour blood pressure at 6 months — pressure fell 2.5 mm Hg on the device and did not change on CPAP
Study: Investigator-initiated, randomised, non-inferiority trial (prespecified margin 1.5 mm Hg)
Population: 220 participants aged 40 years or older with hypertension, increased cardiovascular risk and moderate-to-severe obstructive sleep apnea (index 15 or more events/hour), randomised 1:1 to a mandibular advancement device or CPAP, from 321 recruited for polysomnography at 3 public hospitals; the abstract does not state mean age or sex mix.
Summary: CRESCENT (2024): a mandibular device was non-inferior to CPAP for 24-hour blood pressure at 6 months — pressure fell 2.5 mm Hg on the device.
Result: At 6 months, 24-hour mean arterial pressure had decreased by 2.5 mm Hg from baseline in the device group (P=0.003) and had not changed in the CPAP group (P=0.374); the between-group difference was −1.6 mm Hg (95% CI −3.51 to 0.24; non-inferiority P<0.001). The device group showed larger reductions in all secondary ambulatory pressure parameters, most pronounced during sleep. Daytime sleepiness improved on both treatments with a similar between-group difference, and there were no between-group differences in cardiovascular biomarkers.
Watch out: Blood pressure is a surrogate: CRESCENT shows a dental device lowers pressure at least as much as CPAP in hypertensive patients over 6 months, not that either prevents heart attacks or strokes — that claim belongs to Shelf #302's event trials and is not made here. Non-inferiority also coexists with a point estimate favouring the device, which largely reflects CPAP adherence in practice.
Source: Ou YH et al. Mandibular Advancement vs CPAP for Blood Pressure Reduction in Patients With Obstructive Sleep Apnea. J Am Coll Cardiol. 2024 May 7;83(18):1760-1772. PMID: 38588926. Registry ID: ClinicalTrials.gov NCT04119999, from the record's databank fields.
Card 3 — Synthesis: less index control, equal outcomes — the adherence trade is the mechanism, and it is now shown twice
Study: Synthesis
Population: Synthesis of the cards above: Phillips 2013 (126 randomised, 108 completing both arms) and CRESCENT (220 randomised, 6 months).
Summary: Less index control, equal outcomes — the adherence trade is the mechanism, and it is now shown twice — LIKELY. BP surrogate only; no CV-event claim.
Result: Both trials tell the same story from different angles: CPAP is the stronger index-lowering machine, the device is the one patients wear longer, and measured health outcomes — sleepiness in both trials, quality of life in Phillips, ambulatory blood pressure in CRESCENT — end up similar or device-favouring. CRESCENT's 12-month final report (PMID 42013991, found in the currency sweep) sustained the blood-pressure non-inferiority at a year and is fenced here as a further report of the carded trial, not a third trial. The implanted stimulator (drafted #635) and tissue surgery (drafted #638) are different answers to CPAP intolerance and are not re-carded here; CPAP for cardiovascular-event prevention is Shelf #302.
Watch out: Both trials recruited patients willing to try a device; in a patient who uses CPAP all night every night, CPAP's superior index control is unchallenged by anything on this shelf.
Source: Synthesis of Phillips CL et al. Am J Respir Crit Care Med. 2013;187(8):879-87. PMID: 23413266; Ou YH et al. J Am Coll Cardiol. 2024;83(18):1760-1772. PMID: 38588926. Registry IDs as on the individual cards.