SourceMed · Shelf #9242 in the ask interface

Emergency weight estimation in children — 2 systematic reviews and meta-analyses: the Broselow tape placed just over 50% of children within 10% of their actual weight (pooled PW10 55.6%, PW20 81.2%), below the proposed minimum benchmark of 70% within 10% and 95% within 20%; two-dimensional (length-plus-habitus) systems performed best (PAWPER tape PW10 78.0%, Mercy method PW10 70.9%), parental estimates reached PW10 69.8%, and age-based formulas performed worst

Shelf #9242 · Children’s health

MEASUREMENT ACCURACY — Broselow tape NOT ESTABLISHED to the proposed benchmark; two-dimensional systems closest to it: across two systematic reviews and meta-analyses, the Broselow tape (Broselow Enterprises — the tape is the named subject of the claim) placed only 55.6% of estimates within 10% of actual weight (PW10) and 81.2% within 20% (PW20), against a proposed minimum of PW10 above 70% and PW20 above 95%; the PAWPER tape (PW10 78.0%, PW20 96.6%) and the Mercy method (PW10 70.9%, PW20 95.3%) met or approached that benchmark, parental estimates were intermediate (PW10 69.8%, PW20 87.1%), and age-based formulas were the least accurate systems studied

Stamped: 2026-11-28.

Evidence published: 2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children whose weight cannot be measured during emergency care, how accurately do weight-estimation systems (the Broselow length-based tape, other length- and age-based systems, two-dimensional length-plus-habitus systems such as the PAWPER tape and the Mercy method, and parental estimates) estimate actual body weight — what proportion of estimates fall within 10% and 20% of the true weight?

Balance of the evidence

MEASUREMENT ACCURACY — Broselow tape NOT ESTABLISHED to the proposed benchmark; two-dimensional systems closest to it — Composition: 2 systematic reviews and meta-analyses of emergency weight-estimation systems in children (pooled study counts and participant totals are as each review reports them in its record; the reviews overlap in their primary literature and their figures are not summed). Wells 2017 (Resuscitation): the Broselow tape's weight-estimation accuracy was suboptimal in all populations, with just over 50% of children receiving an estimate within 10% of actual weight, and overestimation in low- and middle-income countries was often extreme, creating potential for harmful medication errors; revisions to the tape over the years showed no evidence of improved performance. Wells 2017 (International Journal of Emergency Medicine): against a proposed minimum benchmark of more than 70% of estimates within 10% of actual weight and more than 95% within 20%, the Broselow tape achieved PW10 55.6% and PW20 81.2%; the two-dimensional systems performed best (PAWPER tape PW10 78.0%, PW20 96.6%; Mercy method PW10 70.9%, PW20 95.3%), parental estimates reached PW10 69.8% and PW20 87.1%, and age-based estimates achieved very low accuracy. PROPOSED MEASUREMENT ACCURACY: when a child's weight cannot be measured, a two-dimensional (length-plus-habitus) system or a parental estimate is the most accurate available route; the Broselow tape and age-based formulas should not be treated as accurate to within 10% for drug dosing.

MeSH: Anthropometry · Body Height · Body Weight · Child · Dimensional Measurement Accuracy · Drug Dosage Calculations · Evaluation Studies as Topic · Female · Humans · Male · Medication Errors · Prospective Studies · Randomized Controlled Trials as Topic · Retrospective Studies

Cards (3)

Card 1 — Broselow tape review: just over 50% of estimates within 10% of actual weight, with extreme overestimation in low- and middle-income populations (Wells 2017, Resuscitation — systematic review and meta-analysis)

Study: Systematic review and meta-analysis (Broselow tape accuracy studies)

Population: A MOOSE-driven systematic review and meta-analysis of studies evaluating the Broselow tape (the length-based tape is the named subject of the claim) as a weight-estimation device, and of studies of its use as a drug-dosing guide; the record does not state a pooled participant total, and none is quoted on this shelf.

Summary: Broselow tape review: just over 50% of estimates within 10% of actual weight, with extreme overestimation in low- and middle-income populations (Wells 2017, Resuscitation — systematic review and meta-analysis)

Result: The tape has undergone substantial changes over the years, but there was no evidence that the changes improved weight-estimation performance. Weight-estimation accuracy was suboptimal in all populations, with just over 50% of children receiving an estimation within 10% of their actual weight; overestimation of weight in low- and middle-income countries was often extreme, indicating significant potential for potentially harmful medication errors. The limited evidence on the tape as a drug-dosing guide indicated it was frequently used incorrectly and contained insufficient information to function without additional resources. The authors conclude the tape lacked sufficient accuracy as a weight-estimation and drug-dosing tool compared with other available techniques.

Watch out: This review's record reports the within-10% performance qualitatively (just over 50%); the precise pooled percentages are carded from the companion meta-analysis below, which shares authors and primary literature — the two reviews are corroboration, not independent evidence, and are not summed anywhere on this shelf.

Source: Wells M et al. The accuracy of the Broselow tape as a weight estimation tool and a drug-dosing guide - A systematic review and meta-analysis. Resuscitation. 2017. PMID: 28958796. Registry ID: none in the record. MeSH: Anthropometry · Body Height · Body Weight · Child · Dimensional Measurement Accuracy · Drug Dosage Calculations · Evaluation Studies as Topic · Female · Humans · Male · Medication Errors · Prospective Studies · Randomized Controlled Trials as Topic · Retrospective Studies

Card 2 — All systems benchmarked: Broselow PW10 55.6% / PW20 81.2%; PAWPER 78.0% / 96.6%; Mercy 70.9% / 95.3%; parental estimates 69.8% / 87.1% (Wells 2017, International Journal of Emergency Medicine — systematic review and meta-analysis)

Study: Systematic review and meta-analysis (weight-estimation systems; no MeSH in the record)

Population: A systematic review and meta-analysis of emergency weight-estimation systems in children, in two arms: one to determine an appropriate accuracy target for estimation systems, and one evaluating existing systems (the Broselow tape, other length- and age-based systems, the two-dimensional PAWPER tape and Mercy method, and parental estimates — systems named as published) against actual measured weight.

Summary: All systems benchmarked: Broselow PW10 55.6% / PW20 81.2%; PAWPER 78.0% / 96.6%; Mercy 70.9% / 95.3%; parental estimates 69.8% / 87.1% (Wells 2017, International Journal of Emergency Medicine — systematic review and meta-analysis)

Result: No evidence supported any specific pre-existing accuracy goal; the authors propose a minimum accuracy of 70% of estimations within 10% of actual weight (PW10 above 70%) and 95% within 20% (PW20 above 95%). The two-dimensional systems performed best: the Mercy method achieved PW10 70.9% and PW20 95.3%, and the PAWPER tape PW10 78.0% and PW20 96.6%; parental estimates achieved PW10 69.8% and PW20 87.1%; the Broselow tape achieved PW10 55.6% and PW20 81.2%. Age-based estimates achieved very low accuracy, and the authors recommend their use be abandoned. Length- and age-based systems also differed substantially in over- vs underestimation between high-income and low- and middle-income populations.

Watch out: The 70%/95% benchmark is the authors' proposal, derived in the same paper, not an external standard — it is carded as a proposed benchmark. Pooled percentages combine studies from populations in which the same system errs in opposite directions, so a pooled PW10 can look acceptable while a specific population's errors are systematically one-sided.

Source: Wells M et al. The accuracy of emergency weight estimation systems in children-a systematic review and meta-analysis. International journal of emergency medicine. 2017. PMID: 28936627. Registry ID: none in the record. MeSH: none in the record

Card 3 — Synthesis — MEASUREMENT ACCURACY: the length-only tape misses its own field's proposed benchmark; habitus information is what closes the gap

Study: Synthesis

Population: 2 systematic reviews and meta-analyses (Wells 2017, Resuscitation; Wells 2017, International Journal of Emergency Medicine) sharing authors and overlapping primary literature — counted as one evidence base, not two.

Summary: Synthesis — MEASUREMENT ACCURACY: the length-only tape misses its own field's proposed benchmark; habitus information is what closes the gap

Result: Both reviews agree: the Broselow tape places only about half to 55.6% of estimates within 10% of actual weight, with the worst errors (overestimation) in low- and middle-income populations, and no tape revision has fixed this. Adding a habitus dimension to length (PAWPER, Mercy) raises within-10% performance to 70.9–78.0% and within-20% performance above 95%, meeting the proposed benchmark; parental estimates nearly match the tape-free systems on PW10 (69.8%) but not PW20 (87.1%). Age-based formulas are the worst performers in both reviews.

Watch out: No sensitivity/specificity pair is reported by either record, so none is quoted; the accuracy currency of this shelf is the proportion of estimates within 10% and 20% of measured weight. Accuracy here is about weight estimation only — whether better estimation improves resuscitation outcomes is a separate question not answered by these reviews.

Source: Synthesis of the reports carded above; no additional source.