SourceMed · Shelf #9260 in the ask interface

Benign biliary strictures: one fully covered metal stent versus multiple plastic stents — 2 multicentre randomised trials (276 patients): stricture resolution was noninferior with the metal stent in both trials (92.6% versus 85.4%; 75.8% versus 77.1% at 24 months), with about one to one-and-a-third fewer ERCP procedures per patient

Shelf #9260 · Liver & gut

LIKELY (benefit)

Stamped: 2026-11-28.

Evidence published: 2016–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with benign biliary strictures treated endoscopically, is a single fully covered self-expanding metal stent noninferior to multiple plastic stents for stricture resolution — and how do the number of procedures, stents and adverse events compare?

Balance of the evidence

LIKELY (benefit) — the benefit is equal stricture resolution with fewer procedures, not higher resolution. Composition: 2 multicentre randomised noninferiority trials, 276 patients in total, in different stricture populations. Coté 2016 (112 patients; strictures after liver transplantation, from chronic pancreatitis, or postoperative): resolution was 92.6% (50 of 54) with a covered metal stent versus 85.4% (41 of 48) with plastic stents, a difference of 7.2% whose one-sided 95% confidence interval (−3.0% to ∞) excluded the prespecified −15% noninferiority margin (P <.001), and the mean number of ERCPs to resolution was 2.14 versus 3.24 (P <.001). Ramchandani 2021 (164 patients, chronic-pancreatitis strictures): resolution at 24 months was 75.8% (47 of 62) with the metal stent versus 77.1% (54 of 70) with multiple plastic stents (P =.008 for noninferiority), with fewer ERCPs (2.6 versus 3.9) and far fewer stents (1.3 versus 7.0), and serious adverse events in 23.8% versus 19.0% (P =.568), with no procedure-related deaths. The tested metal stents are fully covered self-expanding metal stents as a device class; neither record's abstract names a single brand as the claim's subject. LIKELY (benefit): for benign biliary strictures in a duct of at least 6 mm where the stent would not cover the cystic duct, one fully covered metal stent resolves the stricture as reliably as multiple plastic stents while sparing the patient roughly one ERCP.

MeSH: Cholangiopancreatography, Endoscopic Retrograde · Cholestasis · Constriction, Pathologic · Female · Humans · Male · Middle Aged · Plastics · Postoperative Complications · Prosthesis Implantation · Sample Size · Self Expandable Metallic Stents · Stents

Cards (2)

Card 1 — Coté 2016: resolution 92.6% with covered metal versus 85.4% with plastic stents — noninferiority met (margin −15%), with 2.14 versus 3.24 ERCPs to resolution (randomised trial, 112 patients)

Study: Randomized Controlled Trial (multicentre, open-label, noninferiority)

Population: 112 patients with treatment-naive benign biliary strictures — after orthotopic liver transplantation (n = 73), from chronic pancreatitis (n = 35), or postoperative injury (n = 4) — at 8 endoscopic referral centres, randomised to multiple plastic stents (n = 55) or a single fully covered self-expandable metallic stent (n = 57), with reassessment every 3 months (plastic) or 6 months (metal). Patients with a bile duct under 6 mm, or whose cystic duct the metal stent would overlap, were excluded. The primary outcome was stricture resolution within 12 months of therapy.

Summary: Coté 2016: resolution 92.6% with covered metal versus 85.4% with plastic stents — noninferiority met (margin −15%), with 2.14 versus 3.24 ERCPs to resolution (randomised trial, 112 patients)

Result: Resolution was 50 of 54 (92.6%) with the metal stent versus 41 of 48 (85.4%) with plastic stents, a rate difference of 7.2% (one-sided 95% CI −3.0% to ∞; P < .001 against the prespecified −15% noninferiority margin). The mean number of ERCPs to achieve resolution was lower with the metal stent (2.14 versus 3.24; mean difference 1.10, 95% CI 0.74 to 1.46; P < .001). Patients were followed for 12 months after resolution for recurrence.

Watch out: Resolution denominators (54 and 48) are smaller than the randomised numbers (57 and 55) — the record reports resolution among patients reaching assessment. Noninferiority was shown against a generous −15% margin, and the exclusions (small ducts, cystic-duct overlap) bound where the result applies.

Source: Coté GA et al. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial. JAMA. 2016. PMID: 27002446. Registry ID: NCT01221311 (ClinicalTrials.gov, as stated in the record). MeSH: Cholangiopancreatography, Endoscopic Retrograde · Cholestasis · Constriction, Pathologic · Female · Humans · Male · Middle Aged · Plastics · Postoperative Complications · Prosthesis Implantation · Sample Size · Self Expandable Metallic Stents · Stents

Card 2 — Ramchandani 2021 (chronic-pancreatitis strictures): resolution at 24 months 75.8% metal versus 77.1% plastic — noninferior, with 2.6 versus 3.9 ERCPs and 1.3 versus 7.0 stents (randomised trial, 164 patients)

Study: Randomized Controlled Trial (multicentre, noninferiority)

Population: 164 patients with symptomatic benign biliary strictures secondary to chronic pancreatitis at multiple centres, randomised to 12 months of treatment with multiple plastic stents (n = 84) or a single fully covered self-expanding metal stent (n = 80). The primary outcome was stricture resolution at 24 months, defined as no restenting and a 24-month alkaline phosphatase not exceeding twice the level at stenting completion. Eleven patients crossed over from plastic to metal and 10 from metal to plastic.

Summary: Ramchandani 2021 (chronic-pancreatitis strictures): resolution at 24 months 75.8% metal versus 77.1% plastic — noninferior, with 2.6 versus 3.9 ERCPs and 1.3 versus 7.0 stents (randomised trial, 164 patients)

Result: Baseline technical success was 97.6% (plastic) and 98.6% (metal). Stricture resolution at 24 months was 77.1% (54 of 70) with plastic versus 75.8% (47 of 62) with metal stents (P = .008 for noninferiority, intention-to-treat). Mean ERCPs were 3.9 (± 1.3) versus 2.6 (± 1.3) (P < .001) and mean stents placed 7.0 (± 4.4) versus 1.3 (± 0.6) (P < .001, as-treated). Serious adverse events occurred in 16 (19.0%) plastic and 19 (23.8%) metal patients (P = .568), including cholangitis, fever or jaundice (9 versus 7 patients), abdominal pain (5 versus 5), cholecystitis (1 versus 3) and post-ERCP pancreatitis (0 versus 2). No stent- or procedure-related deaths occurred.

Watch out: About one patient in eight crossed over to the other strategy, and resolution denominators (70 and 62) fall short of the randomised numbers (84 and 80); the intention-to-treat noninferiority result is the figure carded. This trial covers chronic-pancreatitis strictures only — the transplant and postoperative populations rest on the Coté trial above.

Source: Ramchandani M et al. Fully Covered Self-Expanding Metal Stent vs Multiple Plastic Stents to Treat Benign Biliary Strictures Secondary to Chronic Pancreatitis: A Multicenter Randomized Trial. Gastroenterology. 2021. PMID: 33741314. Registry ID: NCT01543256 (ClinicalTrials.gov, as stated in the record). MeSH: Adult · Aged · Cholestasis · Coated Materials, Biocompatible · Drainage · Female · Humans · Male · Middle Aged · Pancreatitis, Chronic · Plastics · Prosthesis Design · Self Expandable Metallic Stents · Stents · Treatment Outcome