SourceMed · Shelf #9262 in the ask interface
Dye-spray chromoendoscopy for dysplasia surveillance in longstanding colitis — SPLIT by comparator era: against standard-definition colonoscopy with random biopsies, dye-targeted biopsies found dysplasia in 17 of 102 patients versus 3 (Marion 2008); against modern high-definition colonoscopy, dye spraying and virtual chromoendoscopy added nothing — high-definition alone was noninferior in a 270-patient randomised trial (Iacucci 2018)
Shelf #9262 · Liver & gut
SPLIT — by comparator: dye spraying beat standard-definition random-biopsy surveillance; it did not beat high-definition white-light colonoscopy
Stamped: 2026-11-28.
Evidence published: 2008–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with longstanding ulcerative or Crohn's colitis undergoing surveillance colonoscopy, does dye-spray chromoendoscopy with targeted biopsies detect more dysplasia (neoplasia) than white-light colonoscopy — and does any advantage survive the move to high-definition equipment?
Balance of the evidence
SPLIT — by comparator: dye spraying beat standard-definition random-biopsy surveillance; it did not beat high-definition white-light colonoscopy — Composition: 1 prospective within-patient comparison (102 patients) from the standard-definition era and 1 three-arm randomised noninferiority trial (270 patients) using high-definition equipment; 372 patients in total. Marion 2008 examined each patient by standard surveillance with at least 32 random biopsies, by targeted biopsies without dye, and by methylene-blue dye spray with targeted biopsies: dye-spray targeted biopsies revealed dysplasia in 17 patients (16 low-grade, 1 high-grade) versus 3 patients (all low-grade) with random biopsies (P = 0.001) and 9 patients with targeted biopsies without dye (P = 0.057). Iacucci 2018 randomised patients to high-definition white light, virtual chromoendoscopy (iSCAN) or dye spraying, 90 per arm: virtual chromoendoscopy was noninferior to dye spraying, and high-definition white light alone was noninferior to both for detection of all neoplastic lesions. Both studies measure detection of dysplasia at one examination — a surrogate outcome; neither measures colorectal cancer incidence or mortality, and no such claim is made on this shelf. SPLIT: dye spraying was a genuine advance over random-biopsy surveillance on standard-definition scopes, but on current high-definition equipment it has not been shown to detect more neoplasia than careful white-light inspection.
MeSH: Adenocarcinoma · Adenoma · Adult · Aged · Colitis, Ulcerative · Colonic Neoplasms · Colonoscopy · Coloring Agents · Crohn Disease · Early Detection of Cancer · Female · Humans · Male · Middle Aged · Precancerous Conditions · User-Computer Interface · Young Adult
Cards (2)
Card 1 — Within-patient comparison: dye-spray targeted biopsies found dysplasia in 17 patients versus 3 with random biopsies (P = 0.001) (Marion 2008 — prospective trial, 102 patients)
Study: Prospective within-patient comparison (each patient as own control; not randomised)
Population: 102 patients with extensive longstanding colitis (79 ulcerative colitis, 23 Crohn's colitis) meeting inclusion criteria out of 115 referred, each examined in a single session by three methods in sequence: (a) standard surveillance colonoscopy with 4 random biopsies every 10 cm (at least 32 samples), (b) a targeted-biopsy protocol, and (c) segmental methylene blue 0.01% dye spray with targeted biopsy of any pit-pattern abnormality or lesion made visible. Standard office endoscopic equipment of the period was used, and a single gastrointestinal pathologist reviewed specimens blinded.
Summary: Within-patient comparison: dye-spray targeted biopsies found dysplasia in 17 patients versus 3 with random biopsies (P = 0.001) (Marion 2008 — prospective trial, 102 patients)
Result: Targeted biopsies with dye spray revealed significantly more dysplasia (16 patients with low-grade and 1 with high-grade dysplasia) than random biopsies (3 patients with low-grade dysplasia) (P = 0.001), and more than targeted biopsies without dye spray (8 patients with low-grade and 1 with high-grade dysplasia) (P = 0.057). Targeted biopsies with and without dye spray together detected dysplasia in 20 patients versus 3 by random biopsy (P = 0.0002). There were no adverse events. The authors conclude dye-spray targeted biopsy improves dysplasia yield over conventional random and targeted methods.
Watch out: The three methods were applied in a fixed sequence within one examination, so later passes could benefit from the earlier inspection; and the comparison that matters most for the dye itself (dye-targeted versus plain targeted, P = 0.057) did not reach significance — the large margin is against random biopsies, a weak comparator even then. Detection counts are patients with dysplasia found, not cancers prevented.
Source: Marion JF et al. Chromoendoscopy-targeted biopsies are superior to standard colonoscopic surveillance for detecting dysplasia in inflammatory bowel disease patients: a prospective endoscopic trial. The American journal of gastroenterology. 2008. PMID: 18844620. Registry ID: none in the record. MeSH: Adult · Biopsy · Colectomy · Colonoscopy · Coloring Agents · Female · Humans · Inflammatory Bowel Diseases · Male · Methylene Blue · Prospective Studies
Card 2 — High-definition era: dye spraying and virtual chromoendoscopy both noninferior to — and no better than — high-definition white light alone (Iacucci 2018 — randomised trial, 270 patients)
Study: Randomized Controlled Trial (three-arm, noninferiority)
Population: 270 patients with longstanding colitis and inactive inflammatory bowel disease (55% men; median age 49), randomised to surveillance colonoscopy with high-definition white light alone (n = 90), electronic virtual chromoendoscopy using iSCAN image enhancement (n = 90), or high-definition dye-spraying chromoendoscopy (n = 90), in a randomised noninferiority trial. Detected lesions were classified by Paris classification and Kudo pit pattern and histologically by the Vienna classification.
Summary: High-definition era: dye spraying and virtual chromoendoscopy both noninferior to — and no better than — high-definition white light alone (Iacucci 2018 — randomised trial, 270 patients)
Result: The neoplastic-lesion detection rate with virtual chromoendoscopy was noninferior to dye spraying, and high-definition white light was noninferior to either dye spraying or virtual chromoendoscopy for detection of all neoplastic lesions. Among detected lesions, right-colon location (odds ratio 6.52, 95% CI 1.98 to 22.5) and Kudo pit pattern (odds ratio 21.50, 95% CI 8.65 to 60.10) predicted neoplasia — relative measures from the trial's predictor analysis, printed as recorded. The authors conclude high-definition white light alone was sufficient for detection of dysplasia, adenocarcinoma or all neoplastic lesions in this trial.
Watch out: The record's abstract does not print the per-arm detection rates — only the noninferiority conclusions — so no rates are reconstructed here. Noninferiority of white light does not prove dye spraying is useless in every setting (for example on older equipment, the comparison the Marion card covers); it shows no detected advantage on high-definition scopes in this trial.
Source: Iacucci M et al. A Randomized Trial Comparing High Definition Colonoscopy Alone With High Definition Dye Spraying and Electronic Virtual Chromoendoscopy for Detection of Colonic Neoplastic Lesions During IBD Surveillance Colonoscopy. The American journal of gastroenterology. 2018. PMID: 29134964. Registry ID: none in the record. MeSH: Adenocarcinoma · Adenoma · Adult · Aged · Colitis, Ulcerative · Colonic Neoplasms · Colonoscopy · Coloring Agents · Crohn Disease · Early Detection of Cancer · Female · Humans · Male · Middle Aged · Precancerous Conditions · User-Computer Interface · Young Adult