SourceMed · Shelf #9266 in the ask interface
Molecular PET imaging ([11C]metomidate and 68Ga-pentixafor PET/CT) for subtyping primary aldosteronism — 1 prospective within-patient trial and 2 prospective accuracy studies (documented N = 143, 120 and 60): metomidate PET-CT was non-inferior to adrenal vein sampling for predicting surgical success (accuracy 72.7% versus 63.6% for biochemical success), and pentixafor PET/CT gave sensitivity 92–93% and specificity 85–94% for aldosterone-producing adenoma
Shelf #9266 · Kidney, fluids & electrolytes
PREDICTIVE PERFORMANCE — good enough to guide surgical decisions in the studied settings, not yet shown superior to adrenal vein sampling: in the prospective within-patient MATCH trial (n = 143), [11C]metomidate PET-CT predicted biochemical success after adrenalectomy with 72.7% accuracy versus 63.6% for adrenal vein sampling and met the pre-specified non-inferiority margin; in two prospective pentixafor studies, sensitivity was 92.4% and 93.0% and specificity was 94.4% and 84.6% (sensitivity and specificity labelled in words at first occurrence throughout this shelf) for aldosterone-producing adenoma against pathology-based reference standards
Stamped: 2026-11-28.
Evidence published: 2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with confirmed primary aldosteronism being considered for adrenalectomy, how accurately do molecular PET scans — [11C]metomidate PET-CT and 68Ga-pentixafor PET/CT — identify unilateral, surgically curable disease, compared with adrenal vein sampling and with pathology after surgery?
Balance of the evidence
PREDICTIVE PERFORMANCE — non-inferior to adrenal vein sampling in the one head-to-head trial, with high sensitivity and specificity for pentixafor against pathology — Composition: 1 prospective within-patient trial (MATCH, n = 143) and 2 prospective diagnostic accuracy studies (n = 120 and n = 60). MATCH compared the two tests against surgical outcome in the same patients: metomidate PET-CT was non-inferior to AVS (accuracy difference 9.1 percentage points for biochemical success, within the −17% margin) but not superior, and both tests' absolute accuracies were modest. The pentixafor studies used pathology and CYP11B2 immunohistochemistry rather than AVS as the reference, in surgically selected patients, and report sensitivity 92–93% and specificity 85–94%; their specificity denominators are small and their populations do not match the MATCH population, so the two tracers' figures are not pooled on this shelf.
MeSH: Humans · Adrenal Glands/diagnostic imaging/surgery/blood supply · Hyperaldosteronism*/diagnostic imaging/surgery · Positron Emission Tomography Computed Tomography* · Prospective Studies · Retrospective Studies · Etomidate/analogs & derivatives · Positron Emission Tomography Computed Tomography/methods · Cytochrome P-450 CYP11B2 · Peptides, Cyclic · Coordination Complexes* · Adenoma*/complications · Receptors, CXCR4 · Positron Emission Tomography Computed Tomography*/methods · Gallium Radioisotopes · Hyperaldosteronism*/diagnostic imaging · Receptors, CXCR4/metabolism · Coordination Complexes
Cards (3)
Card 1 — MATCH trial: [11C]metomidate PET-CT was non-inferior to adrenal vein sampling for predicting surgical success in primary aldosteronism (Wu 2023, Nature Medicine — 143 patients, within-patient prospective trial)
Study: Prospective within-patient diagnostic trial (MATCH)
Population: 143 patients with primary aldosteronism assessed prospectively with both [11C]metomidate positron emission tomography computed tomography (MTO) and adrenal vein sampling (AVS) within the same patients; 128 reached 6- to 9-month follow-up, of whom 78 (61%) were treated surgically and 50 (39%) medically. The record names no commercial brand or manufacturer for the tracer.
Summary: MATCH trial: [11C]metomidate PET-CT was non-inferior to adrenal vein sampling for predicting surgical success in primary aldosteronism (Wu 2023, Nature Medicine — 143 patients, within-patient prospective trial)
Result: Of the 78 patients who had surgery, 77 achieved one or more primary aldosteronism surgical outcome criteria for success. The accuracy of MTO in predicting success after adrenalectomy was 72.7% for biochemical success and 65.4% for clinical success; for AVS the accuracies were 63.6% and 61.5%. MTO was not significantly superior, but the differences (9.1%, 95% CI −6.5 to 24.1%, for biochemical success; 3.8%, 95% CI −11.9 to 9.4%, for clinical success) lay within the pre-specified −17% margin for non-inferiority (P = 0.00055 and P = 0.0077). Of 24 serious adverse events, none was considered related to either investigation. The accuracy figures are overall predictive accuracies against surgical outcome, not sensitivity/specificity pairs, and none is quoted as such on this shelf.
Watch out: The reference standard is surgical outcome, available only in the 78 patients selected for surgery, so accuracy is estimated in a surgically selected subset. Non-inferiority was shown against a wide −17% margin; the trial did not show MTO to be superior to AVS, and absolute accuracies for both tests were modest (roughly two-thirds to three-quarters).
Source: Wu X et al. [11C]metomidate PET-CT versus adrenal vein sampling for diagnosing surgically curable primary aldosteronism: a prospective, within-patient trial. Nature medicine. 2023. PMID: 36646800. Registry ID: ClinicalTrials.gov NCT02945904 (as given in the record). MeSH: Humans · Adrenal Glands/diagnostic imaging/surgery/blood supply · Hyperaldosteronism*/diagnostic imaging/surgery · Positron Emission Tomography Computed Tomography* · Prospective Studies · Retrospective Studies · Etomidate/analogs & derivatives
Card 2 — 68Ga-pentixafor PET/CT: sensitivity 92.4% and specificity 94.4% by visual analysis for aldosterone-producing adenoma in a 120-patient prospective series (Zheng 2023, Journal of Clinical Endocrinology and Metabolism)
Study: Prospective diagnostic accuracy study (single-centre series)
Population: 120 prospectively enrolled patients with primary aldosteronism or nonfunctional adrenal adenoma; 66 were diagnosed with aldosterone-producing adenoma, 33 with idiopathic hyperaldosteronism and 21 with nonfunctional adenoma. All underwent 68Ga-pentixafor PET/CT; 77 had adrenalectomy, 76 received pathological diagnoses and 71 had immunohistochemical detection of aldosterone synthase (CYP11B2). The record names no commercial brand or manufacturer for the tracer.
Summary: 68Ga-pentixafor PET/CT: sensitivity 92.4% and specificity 94.4% by visual analysis for aldosterone-producing adenoma in a 120-patient prospective series (Zheng 2023, Journal of Clinical Endocrinology and Metabolism)
Result: For aldosterone-producing adenoma, visual analysis of 68Ga-pentixafor PET/CT gave sensitivity 92.40%, specificity 94.40% and accuracy 93.33% (sensitivity and specificity labelled in words at first occurrence on this shelf). In patients with a nodule larger than 1 cm, a maximum standard uptake value of 7.3 or greater gave specificity 100%. Only 5 patients had successful AVS; in those 5, concordance between AVS and PET/CT for subtyping was 60%. Among the 77 patients who had adrenalectomy, 61 PET/CT scans showed positive lesions, all of which benefited from surgery, and concordance between PET/CT imaging and CYP11B2 staining was 81.69%.
Watch out: The reference standard mixes pathology, immunohistochemistry and clinical diagnosis across subgroups, and only 5 patients had successful AVS, so the head-to-head comparison with AVS in this study is negligible. Sensitivity and specificity were estimated against the study's own diagnostic classification, which incorporated imaging and pathology — a design that can flatter accuracy.
Source: Zheng Y et al. The Value of Targeting CXCR4 With 68Ga-Pentixafor PET/CT for Subtyping Primary Aldosteronism. The Journal of clinical endocrinology and metabolism. 2023. PMID: 37477496. Registry ID: none in the record. MeSH: Humans · Positron Emission Tomography Computed Tomography/methods · Cytochrome P-450 CYP11B2 · Peptides, Cyclic · Coordination Complexes* · Adenoma*/complications · Hyperaldosteronism*/diagnostic imaging/surgery · Receptors, CXCR4
Card 3 — 68Ga-pentixafor PET/CT detected 40 of 43 CYP11B2-positive functional nodules: sensitivity 93.0%, specificity 84.6% against immunohistochemistry (Gao 2023, European Radiology — 60 patients)
Study: Prospective diagnostic accuracy study (lesion-level, pathology-referenced)
Population: 50 patients diagnosed with primary aldosteronism and 10 patients with non-functional adrenal adenoma, all assessed prospectively with 68Ga-pentixafor PET/CT before adrenalectomy, with immunohistochemistry for aldosterone synthase (CYP11B2) and CXCR4 performed on the resected lesions (56 lesions examined). The record names no commercial brand or manufacturer for the tracer.
Summary: 68Ga-pentixafor PET/CT detected 40 of 43 CYP11B2-positive functional nodules: sensitivity 93.0%, specificity 84.6% against immunohistochemistry (Gao 2023, European Radiology — 60 patients)
Result: CYP11B2 immunohistochemistry identified 43 functional nodules; 40 of the 43 were detected on 68Ga-pentixafor PET/CT, and 11 of 13 non-functional nodules were imaging-negative — sensitivity 93.0% and specificity 84.6% (labelled in words at first occurrence on this shelf). The optimum maximum standard uptake value cut-off was 8.95 (area under the curve 0.914). Diagnostic efficiency was higher for nodules larger than 1 cm (sensitivity up to 97.3%). All 43 CYP11B2-positive nodules were CXCR4-positive, and PET/CT uptake agreed with CXCR4 staining in 52 of 56 lesions (92.9%).
Watch out: Accuracy is calculated per lesion in patients already selected for adrenalectomy, not per patient in an unselected primary aldosteronism population, and the specificity denominator is only 13 non-functional nodules — so the specificity estimate is imprecise and the figures do not transfer directly to deciding who should have surgery.
Source: Gao Y et al. Functional nodules in primary aldosteronism: identification of CXCR4 expression with 68Ga-pentixafor PET/CT. European radiology. 2023. PMID: 36070092. Registry ID: none in the record. MeSH: Humans · Positron Emission Tomography Computed Tomography*/methods · Gallium Radioisotopes · Cytochrome P-450 CYP11B2 · Hyperaldosteronism*/diagnostic imaging · Receptors, CXCR4/metabolism · Peptides, Cyclic · Coordination Complexes