SourceMed · Shelf #9274 in the ask interface
Transcutaneous electrical nerve stimulation (TENS) for pain in labour — 2 systematic reviews (19 trials, 1,671 women; 26 trials, 3,348 women) and a 12-woman sham-controlled pilot: the Cochrane review found little difference in pain ratings between TENS and control groups, the later meta-analysis found a small statistically significant effect on pain-intensity reduction (pooled relative risk 1.52, 95% CI 1.35 to 1.70) in mostly low-quality trials, and the sham-controlled pilot (N = 12, printed on this face) found no efficacy; documented total 3,348 women in the largest review (the reviews overlap and are not summed)
Shelf #9274 · Women’s health
POSSIBLE (benefit) — across two overlapping systematic reviews (19 trials / 1,671 women and 26 trials / 3,348 women), TENS may reduce labour pain slightly: the 2020 meta-analysis pooled relative risk for pain-intensity reduction was 1.52 (95% CI 1.35 to 1.70), but the Cochrane review found little difference in pain ratings, most trials were at high risk of bias, and the only sham-controlled trial carded (a 12-woman pilot) found no efficacy; most women using TENS said they would use it again
Stamped: 2026-11-28.
Evidence published: 2009–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In women in labour, does transcutaneous electrical nerve stimulation (TENS), usually applied to the lower back, reduce labour pain compared with placebo devices, routine care, or other analgesia?
Balance of the evidence
POSSIBLE (benefit) — Composition: 2 systematic reviews whose trial sets overlap (their totals are not summed; the shelf's documented total is the larger review's 3,348 women) plus one small sham-controlled pilot trial (N = 12, printed on its card face). Dowswell 2009 (Cochrane; 19 studies, 1,671 women): little difference in pain ratings between TENS and control groups overall, although women receiving TENS to acupuncture points were less likely to report severe pain (relative risk 0.41, 95% CI 0.32 to 0.55); no consistent impact on interventions or outcomes in labour, and no adverse events reported. Thuvarakan 2020 (26 RCTs, 3,348 parturients): a small but statistically significant efficacy on pain-intensity reduction (pooled relative risk 1.52, 95% CI 1.35 to 1.70), with most studies at high risk of bias and low average quality. Thuvarakan 2025 pilot (12 women): no efficacy of any TENS frequency set versus sham over 30 minutes. This shelf is held in the personal-verdict class because the two reviews point in different strengths of direction and the only sham-controlled primary trial carded is a 12-woman pilot. POSSIBLE (benefit): TENS may reduce labour pain slightly and is a reasonable woman-controlled option to offer, but a large analgesic effect is not established.
MeSH: Female · Humans · Labor Pain · Labor, Obstetric · Pregnancy · Randomized Controlled Trials as Topic · Transcutaneous Electric Nerve Stimulation
Cards (3)
Card 1 — Cochrane review: little difference in pain ratings between TENS and control groups overall (Dowswell 2009 — 19 studies, 1,671 women)
Study: Systematic review (Cochrane) of randomised trials
Population: 19 randomised studies including 1,671 women receiving TENS for pain relief in labour versus routine care, alternative pharmacological relief, or placebo devices; 15 studies applied TENS to the back, 2 to acupuncture points, and 2 to the cranium.
Summary: Cochrane review: little difference in pain ratings between TENS and control groups overall (Dowswell 2009 — 19 studies, 1,671 women)
Result: Overall there was little difference in pain ratings between TENS and control groups, although women receiving TENS to acupuncture points were less likely to report severe pain (relative risk 0.41, 95% confidence interval 0.32 to 0.55). The majority of women using TENS said they would be willing to use it again in a future labour. As an adjunct to epidural analgesia there was no evidence TENS reduced pain. There was no consistent evidence of any impact on interventions and outcomes in labour, and no adverse events were reported. The authors conclude there is only limited evidence that TENS reduces pain in labour.
Watch out: This review's trial set overlaps the 2020 meta-analysis below; the two reviews are corroboration over largely the same primary literature, not independent evidence, and their participant totals are not summed anywhere on this shelf.
Source: Dowswell T et al. Transcutaneous electrical nerve stimulation (TENS) for pain relief in labour. The Cochrane database of systematic reviews. 2009. PMID: 19370680. Registry ID: none in the record. MeSH: Female · Humans · Labor Pain · Labor, Obstetric · Pregnancy · Randomized Controlled Trials as Topic · Transcutaneous Electric Nerve Stimulation
Card 2 — Later meta-analysis: small significant effect on pain-intensity reduction, in mostly high-risk-of-bias trials (Thuvarakan 2020 — 26 randomised trials, 3,348 parturients)
Study: Systematic review and meta-analysis of randomised trials
Population: 26 randomised controlled trials of TENS for labour pain involving a total of 3,348 parturients, identified in PubMed, the Cochrane Library, Embase, and Web of Science.
Summary: Later meta-analysis: small significant effect on pain-intensity reduction, in mostly high-risk-of-bias trials (Thuvarakan 2020 — 26 randomised trials, 3,348 parturients)
Result: TENS showed significant efficacy in the reduction of pain intensity (pooled relative risk 1.52, 95% CI 1.35 to 1.70, as printed in the record). Most of the studies had a high risk of bias, and the average grade of the studies indicated low quality. The authors describe the effect as small but statistically significant and state it is not clear whether the results were affected by the poor quality of the studies.
Watch out: The pooled relative risk is labelled relative here as the record prints it; the record does not print the absolute responder rates behind it, and none are asserted on this shelf. Trial overlap with the Cochrane review above means this is not a second independent body of women.
Source: Thuvarakan K et al. Transcutaneous Electrical Nerve Stimulation As A Pain-Relieving Approach in Labor Pain: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. Neuromodulation. 2020. PMID: 32691942. Registry ID: none in the record. MeSH: Female · Humans · Labor Pain · Pain Management · Pregnancy · Randomized Controlled Trials as Topic · Transcutaneous Electric Nerve Stimulation · Treatment Outcome
Card 3 — Sham-controlled pilot: no efficacy of any TENS frequency set versus sham in 12 women (Thuvarakan 2025 — randomised double-blind pilot, N = 12 printed here)
Study: Randomised double-blind sham-controlled pilot trial (conference paper)
Population: 12 healthy low-risk pregnant women admitted for childbirth at term at Gødstrup Hospital, Herning, Denmark (23 were eligible; 12 agreed to participate), randomised to one of two TENS frequency sets or sham-TENS for 30 minutes.
Summary: Sham-controlled pilot: no efficacy of any TENS frequency set versus sham in 12 women (Thuvarakan 2025 — randomised double-blind pilot, N = 12 printed here)
Result: No efficacy of any type of varied TENS frequency compared to sham-TENS was shown (the treatment made no difference in this pilot). The low-to-high frequency set showed a non-significant visual analogue scale reduction versus sham of 1.9 ± 3.4 cm at 10 minutes and 1.0 ± 2.5 cm at 30 minutes. The authors conclude that a properly sized main study of that frequency set is needed.
Watch out: N = 12 is printed on this face: this pilot is far too small to settle the question either way and is carded only because it is the sham-controlled design the review literature lacks; the shelf's verdict rests on the two reviews, not on this pilot.
Source: Thuvarakan K et al. Investigation of varying frequencies of transcutaneous electrical nerve stimulation for labor pain control: a randomized double-blinded sham-controlled pilot study. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2025. PMID: 41337124. Registry ID: none in the record. MeSH: Humans · Transcutaneous Electric Nerve Stimulation · Female · Pilot Projects · Pregnancy · Double-Blind Method · Adult · Labor Pain · Pain Management · Pain Measurement