SourceMed · Shelf #9338 in the ask interface
Ultrasound estimated fetal weight vs actual birth weight — 1 systematic review, 1 twin meta-analysis and 2 primary studies (documented N = 7,395 in the counted studies): mean absolute percentage error 6.2–8.2%, only 67–81% of estimates within 10% of birth weight, and for twin birth-weight discordance of 20% or more sensitivity was 65.4% with specificity 90.8% (labelled in words)
Shelf #9338 · Women’s health
MEASUREMENT ACCURACY — approximate, NOT ESTABLISHED for an exact individual birth weight: across the counted studies (documented N = 7,395) mean absolute percentage error was 6.2–8.2% and only 67–81% of estimates fell within 10% of birth weight, errors are larger at the weight extremes, no formula is consistently superior, and for twin discordance of 20% or more sensitivity was 65.4% and specificity was 90.8% (sensitivity and specificity labelled in words)
Stamped: 2026-11-28.
Evidence published: 2005–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does ultrasound estimated fetal weight predict actual birth weight — what are the mean percentage errors, the proportion of estimates within 10%, and (labelled in words) the sensitivity and specificity for predicting twin birth-weight discordance?
Balance of the evidence
MEASUREMENT ACCURACY — approximate, NOT ESTABLISHED for an exact individual birth weight — Composition: 1 systematic review, 1 twin meta-analysis (5,826 twin pregnancies) and 2 primary studies (620 fetuses; 949 women); documented N = 7,395 in the counted studies. Dudley 2005 (systematic review, 11 methods): no consistently superior method has emerged, random errors are large, and accuracy is compromised by large intra- and interobserver variability. Leombroni 2017 (5,826 twin pregnancies): estimated-fetal-weight discordance of 20% or more had sensitivity 65.4% and specificity 90.8% (labelled in words) for birth-weight discordance of 20% or more, improving when scanning was within 3 days of birth. Mattsson 2007 (620 fetuses): with the Hadlock 2 formula the mean absolute percent error was 6.2% and 81% of estimates were within 10% of birth weight, with overestimation below 2,500 g and underestimation above 4,000 g. Tas 2019 (949 women): mean absolute percent error 8.2 ± 6.5% with a failure ratio (error over 10%) of 33%. PROPOSED MEASUREMENT ACCURACY: ultrasound fetal weight estimation is a useful approximation with roughly 1-in-5 to 1-in-3 estimates more than 10% out — it must not be treated as the baby's weight.
MeSH: Fetal Weight · Birth Weight · Ultrasonography, Prenatal · Sensitivity and Specificity · Observer Variation
Cards (4)
Card 1 — The review verdict: no formula is consistently superior, random errors are large, and observer variability is the binding constraint (Dudley 2005, Ultrasound in Obstetrics & Gynecology — systematic review of 11 methods)
Study: Systematic review (measurement accuracy; n not documented in the record)
Population: Systematic review of studies comparing ultrasound estimated fetal weight with birth weight, covering mathematically based non-linear regression methods and physically based volumetric methods; four databases searched. The record states no pooled subject number — N not documented in the record.
Summary: The review verdict: no formula is consistently superior, random errors are large, and observer variability is the binding constraint (Dudley 2005, Ultrasound in Obstetrics & Gynecology — systematic review of 11 methods)
Result: No consistently superior method has emerged. Volumetric methods provide some theoretical advantages. Random errors are large and must be reduced if clinical errors are to be avoided. The accuracy of estimated fetal weight is compromised by large intra- and interobserver variability in fetal measurement. The author lists the remedies: averaging of multiple measurements, improvements in image quality, uniform calibration of equipment, careful design and refinement of measurement methods, acknowledgement of a long learning curve, regular audit of measurement quality, and further work on the universal validity of formulae. The review also notes fetal weight estimation has poor sensitivity (labelled in words) for prediction of fetal compromise.
Watch out: The record gives no pooled N, so this card contributes no N to the shelf total. Its 'poor sensitivity' phrase is the review's own wording about predicting compromise, a different question from weight error, and is carded as such.
Source: Dudley NJ. A systematic review of the ultrasound estimation of fetal weight. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2005. PMID: 15505877. Registry ID: none in the record. MeSH: Birth Weight · Fetal Weight · Humans · Imaging, Three-Dimensional · Infant, Low Birth Weight · Infant, Newborn · Observer Variation · Reference Values · Reproducibility of Results · Ultrasonography, Prenatal
Card 2 — Twins: for birth-weight discordance of 20% or more, sensitivity was 65.4% and specificity was 90.8% (labelled in words) — better the closer the scan is to birth (Leombroni 2017, Ultrasound in Obstetrics & Gynecology — 5,826 twin pregnancies)
Study: Systematic review and meta-analysis (diagnostic accuracy; n = 5,826 pregnancies)
Population: Systematic review and meta-analysis of 20 studies including 5,826 twin pregnancies, assessing sonographic estimated-fetal-weight discordance and abdominal-circumference discordance against actual birth-weight discordance, by cut-off and by scan-to-birth interval.
Summary: Twins: for birth-weight discordance of 20% or more, sensitivity was 65.4% and specificity was 90.8% (labelled in words) — better the closer the scan is to birth (Leombroni 2017, Ultrasound in Obstetrics & Gynecology — 5,826 twin pregnancies)
Result: Estimated-fetal-weight discordance of 20% or more had a sensitivity of 65.4% and a specificity of 90.8% (sensitivity and specificity labelled in words) in predicting birth-weight discordance of 20% or more. The predictive performance of ultrasound performed within 1 month, 2 weeks and 3 days before birth was 61.4%, 72.3% and 78.9% respectively. At a 25% cut-off, sensitivity was 57.7% and specificity was 95.2%. For abdominal-circumference discordance predicting birth-weight discordance of 25% or more, sensitivity was 70.8% and specificity was 86.4%. The authors conclude ultrasound estimated-fetal-weight discordance has overall moderate accuracy in predicting birth-weight discordance in twin pregnancy.
Watch out: Every sensitivity/specificity pair on this card is labelled in words. Discordance prediction in twins is a relative comparison between two fetuses, which is an easier task than estimating one baby's absolute weight — the primary-study cards carry that error.
Source: Leombroni M et al. Diagnostic accuracy of ultrasound in predicting birth-weight discordance in twin pregnancy: systematic review and meta-analysis. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2017. PMID: 27804184. Registry ID: none in the record. MeSH: Birth Weight · Crown-Rump Length · Female · Fetal Weight · Humans · Predictive Value of Tests · Pregnancy · Pregnancy, Twin · Prenatal Care · Twins · Ultrasonography, Prenatal
Card 3 — Midwife sonographers: mean absolute error 6.2%, 81% within 10% — but small babies are overestimated and large babies underestimated (Mattsson 2007, Acta Obstetricia et Gynecologica Scandinavica — 620 fetuses)
Study: Primary accuracy study (prospective estimations vs birth weight; n = 620 fetuses)
Population: 620 fetuses in 607 pregnancies (twins, n = 27, analysed separately) whose fetal weight was estimated by ultrasound-trained midwives within 3 days before delivery, comparing 5 estimation formulas against actual birth weight, including the Hadlock 2 formula (biparietal diameter, abdominal circumference and femur length) used in their unit — formula named as published.
Summary: Midwife sonographers: mean absolute error 6.2%, 81% within 10% — but small babies are overestimated and large babies underestimated (Mattsson 2007, Acta Obstetricia et Gynecologica Scandinavica — 620 fetuses)
Result: With the Hadlock 2 formula, mean absolute percent error was 6.2% and the standard deviation of error was 7.6% of mean birth weight. A total of 81% of estimates were within 10% of the actual birth weight. All formulas tended to overestimate the weight of twins and fetuses weighing under 2,500 g and underestimate the weight of fetuses over 4,000 g. Fetal presentation did not significantly influence accuracy. Hadlock 2 gave the highest intraclass correlation, 0.910. The authors conclude ultrasound estimation by midwives is feasible and of similar accuracy to the original studies, with major errors possible in small and large birth-weight groups.
Watch out: The intraclass correlation of 0.910 is a reliability/agreement statistic, not a percentage of correct estimates: as a plain-words guide, a reliability of 0.70 suffices for comparing groups and 0.90 is the ideal for individual-patient decisions — this value sits at that individual-decision ideal, yet 19% of estimates were still more than 10% out, which is why both numbers are carried.
Source: Mattsson N et al. Good accuracy of ultrasound estimations of fetal weight performed by midwives. Acta obstetricia et gynecologica Scandinavica. 2007. PMID: 17520400. Registry ID: none in the record. MeSH: Biometry · Birth Weight · Female · Fetal Weight · Humans · Infant, Newborn · Midwifery · Pregnancy · Ultrasonography, Prenatal
Card 4 — The less favourable primary study: mean absolute percent error 8.2%, and one in three estimates more than 10% out (Tas 2019, Pakistan Journal of Medical Sciences — 949 term singleton pregnancies)
Study: Primary accuracy study (prospective; n = 949)
Population: 949 singleton term pregnant women who delivered at a tertiary centre in 2017, with maternal, sonographic and neonatal characteristics recorded and sonographic fetal weight estimation compared with neonatal birth weight; the record carries no MeSH terms — MeSH: none in the record.
Summary: The less favourable primary study: mean absolute percent error 8.2%, and one in three estimates more than 10% out (Tas 2019, Pakistan Journal of Medical Sciences — 949 term singleton pregnancies)
Result: The mean absolute percent error of sonographic fetal weight estimation was 8.2 ± 6.5%, and the overall failure ratio (absolute percent error over 10%) was 33%. Primiparity and cephalic presentation were significantly more common in the failure group, and mean neonatal birth weight was significantly lower in the failure group (3,250 ± 565 g) than the success group (3,404 ± 410 g). Logistic regression found primiparous woman, cephalic presentation and birth weight under 3,300 g to be independent risk factors for estimation failure (relative risks 1.6, 2.8 and 2.4). The authors conclude sonographic estimation correlates with birth weight but its accuracy is still unsatisfactory and depends on many unpredictable factors. (These are risk-factor ratios for estimation failure, not treatment effects.)
Watch out: This record carries no MeSH terms — stated plainly on the card rather than supplied. Single-centre term population; the 33% failure ratio is this centre's figure, read alongside the 19% beyond-10% figure in Mattsson 2007.
Source: Tas EE et al. Accuracy of sonographic fetal weight estimation in full-term singleton pregnant women. Pakistan journal of medical sciences. 2019. PMID: 30881392. Registry ID: none in the record. MeSH: none in the record