SourceMed · Shelf #9341 in the ask interface
Transvaginal cervical length for predicting preterm birth — 2 systematic reviews, 1 meta-analysis and 2 primary studies (documented N = 34,492 in the sources stating a pooled N): a length under 15 mm in symptomatic women predicts birth within a week with sensitivity 59.9% and specificity 90.5% (labelled in words), in asymptomatic women a 25 mm cut-off carries a positive likelihood ratio of 6.29 but a negative likelihood ratio of only 0.79, and the founding cohort's relative risk reaches 13.99 at 13 mm or less
Shelf #9341 · Women’s health
PREDICTIVE PERFORMANCE — established for risk stratification, NOT ESTABLISHED as a standalone individual prediction: across 2 systematic reviews, 1 meta-analysis and 2 primary studies (documented N = 34,492 in the sources stating a pooled N) cervical length under 15 mm in symptomatic women predicted birth within 1 week with sensitivity 59.9% and specificity 90.5% (labelled in words), a 25 mm cut-off in asymptomatic women carried a positive likelihood ratio of 6.29 but a negative likelihood ratio of only 0.79, and in the primary studies a 20 mm cut-off had sensitivity 88.24% with specificity 60.47% while the founding cohort showed a graded relative risk up to 13.99 — a short cervix raises risk several-fold, but most women flagged do not deliver early and a normal length does not exclude it
Stamped: 2026-11-28.
Evidence published: 1996–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How well does transvaginal ultrasound cervical length predict spontaneous preterm birth — what are its sensitivity, specificity and likelihood ratios (labelled in words) at the 15 mm and 25 mm cut-offs, in symptomatic and asymptomatic women, singletons and twins?
Balance of the evidence
PREDICTIVE PERFORMANCE — established for risk stratification, NOT ESTABLISHED as a standalone individual prediction — Composition: 2 systematic reviews, 1 meta-analysis and 2 primary studies (documented N = 34,492 across the sources that state a pooled N — Honest 2003's 31,577 women and Iams 1996's 2,915 women; the symptomatic meta-analysis and the Gokce study state no pooled/subject N in their records). Sotiriadis 2010 (28 studies, symptomatic women): cervical length under 15 mm predicted birth within 1 week with sensitivity 59.9%, specificity 90.5%, positive likelihood ratio 5.71 and negative likelihood ratio 0.51 (sensitivity and specificity labelled in words), with considerable heterogeneity. Honest 2003 (46 studies, 31,577 women): for asymptomatic women tested before 20 weeks at a 25 mm threshold against birth before 34 weeks, the summary positive likelihood ratio was 6.29 and the negative likelihood ratio 0.79. Iams 1996 (2,915 women): relative risk of delivery before 35 weeks rose steadily as length fell, reaching 6.19 at 26 mm or less and 13.99 at 13 mm or less against the longest quartile, on a 4.3% absolute outcome rate. Gokce 2022 (primary study, symptomatic women with length under 25 mm): at a 20 mm cut-off sensitivity was 88.24% and specificity was 60.47% for birth within 7 days, while at 10 mm sensitivity was 23.53% and specificity was 91.86%.
MeSH: Cervical Length Measurement · Premature Birth · Sensitivity and Specificity · Predictive Value of Tests · Ultrasonography, Prenatal
Cards (4)
Card 1 — Symptomatic women, under 15 mm: sensitivity 59.9% and specificity 90.5% (labelled in words) for birth within a week (Sotiriadis 2010, Ultrasound in Obstetrics & Gynecology — meta-analysis of 28 studies)
Study: Meta-analysis (predictive accuracy, symptomatic women; 28 studies)
Population: Meta-analysis of 28 studies of transvaginal ultrasound cervical length measurement in women with threatened preterm labour (symptomatic women), pooling sensitivity, specificity and likelihood ratios for preterm birth outcomes; the record states no pooled subject number — N not documented in the record.
Summary: Symptomatic women, under 15 mm: sensitivity 59.9% and specificity 90.5% (labelled in words) for birth within a week (Sotiriadis 2010, Ultrasound in Obstetrics & Gynecology — meta-analysis of 28 studies)
Result: For birth within 1 week from presentation, the pooled sensitivity, specificity, positive likelihood ratio and negative likelihood ratio of cervical length under 15 mm were sensitivity 59.9% (95% CI 52.7–66.8%), specificity 90.5% (95% CI 89.0–91.9%), positive likelihood ratio 5.71 (95% CI 3.77–8.65) and negative likelihood ratio 0.51 (95% CI 0.33–0.80) — sensitivity and specificity labelled in words. For studies presenting at or before 34 weeks, sensitivity was 71.0% and specificity was 89.8%. For prediction of birth before 34 weeks, sensitivity was 46.2% and specificity was 93.7%. There was considerable heterogeneity across studies in most estimates. The authors conclude cervical length in symptomatic women can detect a significant proportion of those who will deliver within 1 week and help rationalize management.
Watch out: The record gives no pooled subject number, so this card contributes no N to the shelf total. Sensitivity under 60% for the headline outcome means about 4 in 10 women who will deliver within a week are not flagged by the 15 mm cut-off.
Source: Sotiriadis A et al. Transvaginal cervical length measurement for prediction of preterm birth in women with threatened preterm labor: a meta-analysis. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2010. PMID: 20014326. Registry ID: none in the record. MeSH: Cervical Length Measurement · Cervix Uteri · Female · Gestational Age · Humans · Obstetric Labor, Premature · Predictive Value of Tests · Pregnancy · Premature Birth · Risk Factors · Sensitivity and Specificity
Card 2 — Asymptomatic women, 25 mm before 20 weeks: positive likelihood ratio 6.29, negative likelihood ratio only 0.79 (Honest 2003, Ultrasound in Obstetrics & Gynecology — 46 studies, 31,577 women)
Study: Systematic review (predictive accuracy; n = 31,577 women)
Population: Systematic review of 46 primary articles including 31,577 women (33 studies in asymptomatic and 13 in symptomatic women), forming 2×2 tables for various cervical length thresholds against birth before 32, 34 and 37 weeks, stratified by singleton or twin pregnancy, gestation at testing and threshold.
Summary: Asymptomatic women, 25 mm before 20 weeks: positive likelihood ratio 6.29, negative likelihood ratio only 0.79 (Honest 2003, Ultrasound in Obstetrics & Gynecology — 46 studies, 31,577 women)
Result: The most commonly reported subgroup was testing of asymptomatic women before 20 weeks' gestation using a threshold cervical length of 25 mm with spontaneous preterm birth before 34 weeks as the reference standard: the summary positive likelihood ratio was 6.29 (95% CI 3.29–12.02), with a corresponding negative likelihood ratio of 0.79 (95% CI 0.65–0.95). There was wide variation among studies in gestation at testing, threshold definition and reference standard. The authors conclude transvaginal cervical sonography identifies women at higher risk of spontaneous preterm birth, and that cervical length and funneling, alone or combined, appear useful in predicting preterm birth in asymptomatic women depending on the threshold chosen.
Watch out: A negative likelihood ratio of 0.79 barely moves the risk down — a cervix of 25 mm or more is weak reassurance, which is the central caution of this shelf. Likelihood ratios are carded instead of a sensitivity/specificity pair because that is what this record pools.
Source: Honest H et al. Accuracy of cervical transvaginal sonography in predicting preterm birth: a systematic review. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2003. PMID: 12942506. Registry ID: none in the record. MeSH: Data Collection · Female · Humans · Obstetric Labor, Premature · Pregnancy · Prospective Studies · Sensitivity and Specificity · Ultrasonography, Prenatal
Card 3 — The founding cohort: risk climbs steadily as the cervix shortens — relative risk 6.19 at 26 mm or less and 13.99 at 13 mm or less, against the longest quartile (Iams 1996, New England Journal of Medicine — 2,915 women)
Study: Primary predictive study (prospective multicentre cohort; n = 2,915)
Population: 2,915 women with singleton pregnancies at 10 university-affiliated prenatal clinics, examined by vaginal ultrasonography at approximately 24 weeks of gestation (2,531 examined again at approximately 28 weeks), with spontaneous delivery before 35 weeks as the outcome (126 women, 4.3%).
Summary: The founding cohort: risk climbs steadily as the cervix shortens — relative risk 6.19 at 26 mm or less and 13.99 at 13 mm or less, against the longest quartile (Iams 1996, New England Journal of Medicine — 2,915 women)
Result: Cervical length was normally distributed at 24 weeks (mean 35.2 ± 8.3 mm). The relative risk of preterm delivery increased as cervical length decreased. Compared with women above the 75th percentile, relative risks at 24 weeks were 1.98 at or below the 75th percentile (40 mm), 2.35 at or below the 50th percentile (35 mm), 3.79 at or below the 25th percentile (30 mm), 6.19 at or below the 10th percentile (26 mm), 9.49 at or below the 5th percentile (22 mm) and 13.99 at or below the 1st percentile (13 mm). The corresponding relative risks at 28 weeks were 2.80, 3.52, 5.39, 9.57, 13.88 and 24.94. These are relative risks of an outcome, printed with the absolute outcome rate alongside (4.3% delivered before 35 weeks). The authors conclude the risk of spontaneous preterm delivery is increased in women found to have a short cervix by vaginal ultrasonography.
Watch out: This study reports a graded relative-risk ladder, not a sensitivity/specificity pair — none is derived from it here. Even at the shortest lengths the relative risk applies to a 4.3% baseline outcome, so most women with a short cervix in this cohort did not deliver before 35 weeks.
Source: Iams JD et al. The length of the cervix and the risk of spontaneous premature delivery. National Institute of Child Health and Human Development Maternal Fetal Medicine Unit Network. The New England journal of medicine. 1996. PMID: 8569824. Registry ID: none in the record. MeSH: Cervix Uteri · Female · Humans · Obstetric Labor, Premature · Pregnancy · Pregnancy Trimester, Second · Prospective Studies · Regression Analysis · Risk · Sensitivity and Specificity · Ultrasonography, Prenatal · Uterine Cervical Incompetence
Card 4 — One primary study, three cut-offs: at 20 mm sensitivity 88.24% with specificity 60.47%; at 10 mm sensitivity 23.53% with specificity 91.86% (labelled in words) (Gokce 2022, Journal of Maternal-Fetal & Neonatal Medicine — N not documented in the record)
Study: Primary predictive study (prospective cohort; n not documented in the record)
Population: Prospective cohort of women presenting with preterm labour symptoms, transvaginal cervical length under 25 mm and clinically intact membranes at a university obstetrics department (August 2017 to February 2019), testing cervical length cut-offs and placental alpha microglobulin-1 (PAMG-1) against spontaneous preterm birth within 7 days; the record states no subject number — N not documented in the record.
Summary: One primary study, three cut-offs: at 20 mm sensitivity 88.24% with specificity 60.47%; at 10 mm sensitivity 23.53% with specificity 91.86% (labelled in words) (Gokce 2022, Journal of Maternal-Fetal & Neonatal Medicine — N not documented in the record)
Result: For birth within 7 days, at a 20 mm cervical length cut-off sensitivity was 88.24% and specificity was 60.47%, with negative predictive value 96.3% and positive predictive value 30.61% (sensitivity and specificity labelled in words). At a 15 mm cut-off sensitivity was 58.8% and specificity was 81.4%; at 10 mm sensitivity was 23.53% and specificity was 91.86%. PAMG-1 positivity had sensitivity 52.94% and specificity 98.84%, with an accuracy of 91.26%, better than any cervical length cut-off. The authors conclude PAMG-1, with its high negative and positive predictive values, will contribute to clinical decisions in this population.
Watch out: The record gives no subject number, so this card contributes no N to the shelf total. The cut-off trade-off on this single card is the shelf in miniature: loosening the cut-off buys sensitivity at the price of specificity, and no cut-off gives both.
Source: Gokce A et al. Role of cervical length and placental alpha microglobulin-1 to predict preterm birth. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2022. PMID: 33225786. Registry ID: none in the record. MeSH: Cervical Length Measurement · Cervix Uteri · Female · Humans · Infant, Newborn · Obstetric Labor, Premature · Placenta · Predictive Value of Tests · Pregnancy · Premature Birth · Prospective Studies · Sensitivity and Specificity