Exhaled carbon monoxide to verify smoking status — 4 studies (documented N = 2,342 across 4 studies): the best cut-off is population-dependent — 3 ppm gave sensitivity 98.1% and specificity 95.8% (labelled in words) in women prisoners, but the same 3 ppm cut-off gave sensitivity only 43.6% with specificity 97.24% in a workplace sample, and the commonly used 8–10 ppm cut-offs misclassify light smokers
Shelf #9342 · Lungs, breathing & sleep
PREDICTIVE PERFORMANCE — NOT ESTABLISHED for a universal cut-off: across 4 studies (documented N = 2,342) exhaled carbon monoxide separates smokers from non-smokers strongly at the group level (area under the curve 99% in one study, 74.9% in another), but the optimal cut-off and its sensitivity move with the population — at 3 ppm sensitivity was 98.1% with specificity 95.8% in one sample and sensitivity was 43.6% with specificity 97.24% in another (sensitivity and specificity labelled in words) — so a single ppm threshold cannot certify abstinence across settings
Stamped: 2026-11-28.
Evidence published: 1998–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does exhaled (expired) carbon monoxide verify self-reported smoking status — what sensitivity and specificity (labelled in words) do the proposed cut-offs of 3 ppm and 8–10 ppm achieve, and how much does the answer depend on the population?
Balance of the evidence
PREDICTIVE PERFORMANCE — NOT ESTABLISHED for a universal cut-off — Composition: 4 studies (documented N = 2,342: 374 + 643 + 1,117 + 208). Cropsey 2006 (374 women prisoners): receiver-operating analysis found a 3 ppm cut-off gave the best sensitivity (98.1%) and specificity (95.8%), with area under the curve 99%, and cut-offs above 3 ppm misclassify some smokers as non-smokers. Ramani 2023 (643 workplace subjects, Bedfont EC50 Smokerlyzer — named as published): the same 3 ppm region gave sensitivity 43.6% and specificity 97.24%, with area under the curve 74.9% and diagnostic accuracy 82.89%. Morabia 2001 (552 men and 565 women): against combined biomarkers, self-report had sensitivity 88.6% and specificity 87.2%, falling when heavy smokers were excluded. Becoña 1998 (208 smokers): expired carbon monoxide and self-report showed around 100% concordance at end of treatment and at 6 and 12 months.
MeSH: Carbon Monoxide · Breath Tests · Smoking · Sensitivity and Specificity · ROC Curve
Cards (4)
Card 1 — In women prisoners the best cut-off was 3 ppm — sensitivity 98.1%, specificity 95.8% (labelled in words), area under the curve 99% (Cropsey 2006, Nicotine & Tobacco Research — 374 women)
Study: Diagnostic accuracy study (cut-off derivation vs self-report; n = 374)
Population: 374 female prisoners at a correctional facility in Virginia (mean age 34.5 years; smoking prevalence 74.1%) whose expired carbon monoxide levels were compared with smoking self-report by receiver-operating characteristic analysis, with subgroups including Black and light smokers (under 10 cigarettes/day).
Summary: In women prisoners the best cut-off was 3 ppm — sensitivity 98.1%, specificity 95.8% (labelled in words), area under the curve 99% (Cropsey 2006, Nicotine & Tobacco Research — 374 women)
Result: A carbon monoxide cut-off of 3 ppm resulted in the best sensitivity (98.1%) and specificity (95.8%) — sensitivity and specificity labelled in words. The overall receiver-operating area under the curve was 99% (95% CI 98.2–99.9%). The same cut-off was optimal for smoking subgroups including Black and light smokers. Cut-offs of 8–10 ppm are commonly employed for abstinence validation, and the authors conclude cut-offs higher than 3 ppm may misclassify some smokers as non-smokers and underestimate the prevalence of smoking.
Watch out: The reference standard here is self-report in a setting where smoking is prevalent and mostly admitted; a cut-off tuned in this population is the favourable end of the shelf's range, as the Ramani card shows.
Source: Cropsey KL et al. Expired carbon monoxide levels in self-reported smokers and nonsmokers in prison. Nicotine & tobacco research : official journal of the Society for Research on Nicotine and Tobacco. 2006. PMID: 17008192. Registry ID: none in the record. MeSH: Adult · Breath Tests · Carbon Dioxide · Female · Humans · Predictive Value of Tests · Prevalence · Prisoners · ROC Curve · Sensitivity and Specificity · Smoking · Smoking Cessation · Smoking Prevention · Virginia
Card 2 — The same 3 ppm region in a workplace sample: sensitivity only 43.6%, specificity 97.24% (labelled in words), area under the curve 74.9% (Ramani 2023, Tobacco Use Insights — 643 subjects)
Study: Diagnostic accuracy study (handheld device vs smoking status; n = 643)
Population: 643 healthy individuals at a workplace tested for exhaled carbon monoxide with the Bedfont EC50 Smokerlyzer handheld machine (named as published), compared with smoking status and pack-years, in a cross-sectional study at a preventive oncology setting; this record carries no MeSH terms — MeSH: none in the record.
Summary: The same 3 ppm region in a workplace sample: sensitivity only 43.6%, specificity 97.24% (labelled in words), area under the curve 74.9% (Ramani 2023, Tobacco Use Insights — 643 subjects)
Result: There was a statistically significant difference (P<0.001) in median (interquartile range) exhaled carbon monoxide between smokers and non-smokers: 2 (1, 5) ppm vs 1 (1, 2) ppm. Exhaled carbon monoxide correlated moderately with pack-years (Spearman correlation 0.463). The receiver-operating curve gave a cut-off of 2.5 ppm with sensitivity 43.6% and 1 − specificity 2.76% — that is, specificity 97.24% (sensitivity and specificity labelled in words) — rounded to 3 ppm. The area under the curve was 74.9%, indicating moderate discrimination, and the diagnostic accuracy was 82.89%. The authors suggest that where the goal is complete abstinence, a stringent cut-off in the range of 3–4 ppm should be used.
Watch out: This record carries no MeSH terms — stated plainly on the card. The record prints '1 − specificity' as 2.76%; the specificity of 97.24% carded is that printed value subtracted from 100%, and both forms are shown so the arithmetic is visible.
Source: Ramani VK et al. Assessment of Carbon Monoxide in Exhaled Breath using the Smokerlyzer Handheld Machine: A Cross-Sectional Study. Tobacco use insights. 2023. PMID: 37384051. Registry ID: none in the record. MeSH: none in the record
Card 3 — Self-report itself is the moving target: against two biomarkers together, questionnaire sensitivity was 88.6% and specificity 87.2% (labelled in words) (Morabia 2001, Preventive Medicine — 1,117 adults)
Study: Validation study (self-report vs two biomarkers; n = 1,117)
Population: 552 men and 565 women in a 1996 population-based Swiss survey, whose self-reported smoking was compared with salivary thiocyanate and expired carbon monoxide measured simultaneously, singly and in combination.
Summary: Self-report itself is the moving target: against two biomarkers together, questionnaire sensitivity was 88.6% and specificity 87.2% (labelled in words) (Morabia 2001, Preventive Medicine — 1,117 adults)
Result: Sensitivity of self-reported smoking relative to a single biomarker was low: 38.2% against salivary thiocyanate at 100 mg/L or more, 56.4% at 150 mg/L or more, and 62.6% against carbon monoxide at 9 ppm or more (sensitivity labelled in words). When true smokers were defined as people with high concentrations of both biomarkers, overall sensitivity was 88.6% and specificity was 87.2%. In women, sensitivity increased from 85% to 89% when subjects exposed to passive smoking were removed; when heavy smokers were excluded, sensitivity decreased to 63% in men and 71% in women. The authors conclude valid responses can be obtained for self-reported current smoking in population surveys, but the validity of questionnaires can be underestimated if the reference standard is a single biomarker.
Watch out: This card validates the reference standard the other cards use, not the breath test directly: carbon monoxide at 9 ppm or more as a lone standard made self-report look far worse (sensitivity 62.6%) than the combined standard did (88.6%) — cut-off choice changes the verdict on both sides of the comparison.
Source: Morabia A et al. Validation of self-reported smoking status by simultaneous measurement of carbon monoxide and salivary thiocyanate. Preventive medicine. 2001. PMID: 11162330. Registry ID: none in the record. MeSH: Adult · Age Distribution · Biomarkers · Breath Tests · Carbon Monoxide · Female · Half-Life · Humans · Male · Reproducibility of Results · Saliva · Sensitivity and Specificity · Sex Distribution · Smoking · Surveys and Questionnaires · Switzerland · Thiocyanates
Card 4 — In a treatment programme, breath carbon monoxide and self-report agreed almost completely — around 100% concordance at end of treatment and at 6 and 12 months (Becoña 1998, Psychological Reports — 208 smokers)
Study: Validation study (treatment-programme concordance; n = 208)
Population: 208 smokers who had attended a behavioural programme for smoking cessation, whose self-reported smoking rate and expired air carbon monoxide were compared at the end of treatment and at 6- and 12-month follow-ups.
Summary: In a treatment programme, breath carbon monoxide and self-report agreed almost completely — around 100% concordance at end of treatment and at 6 and 12 months (Becoña 1998, Psychological Reports — 208 smokers)
Result: A close relationship between carbon monoxide levels and self-reports was found at the end of treatment and in all follow-ups (6 and 12 months), around 100% concordance. The authors conclude support was found for the use of an expired air carbon monoxide measure as a valid and easy way of corroborating self-report data when required. The record prints no sensitivity or specificity pair for this study — none is derived here; the carded figure is the concordance the record reports.
Watch out: Concordance in a cessation programme — where participants know they will be tested — is the easiest setting for agreement and does not rescue a universal cut-off; it is carded as the favourable-context end of the evidence, and no accuracy pair is invented for it.
Source: Becoña E et al. Self-reported smoking and measurement of expired air carbon monoxide in a clinical treatment. Psychological reports. 1998. PMID: 9775688. Registry ID: none in the record. MeSH: Adult · Behavior Therapy · Breath Tests · Carbon Monoxide · Female · Humans · Male · Sensitivity and Specificity · Smoking · Smoking Cessation · Treatment Outcome · Truth Disclosure