SourceMed · Shelf #9367 in the ask interface
Superparamagnetic iron oxide (magnetic) tracer for sentinel lymph node biopsy in early breast cancer — 3 randomised trials (documented N = 563 patients): detection rates 99.3% with the magnetic tracer vs 98.6–99.3% with radioisotope ± blue dye (the treatment made no difference — non-inferior in every trial)
Shelf #9367 · Cancer
LIKELY (the treatment made no difference) — three randomised trials agree the magnetic tracer is non-inferior to radioisotope ± blue dye for sentinel-node detection (per-patient detection about 99% with both), so the choice between tracers turns on logistics and skin staining, not detection accuracy
Stamped: 2026-11-28.
Evidence published: 2019–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with clinically node-negative early breast cancer, does sentinel lymph node detection with a superparamagnetic iron oxide magnetic tracer detect sentinel nodes as reliably as the conventional radioisotope (with or without blue dye) technique?
Balance of the evidence
LIKELY (the treatment made no difference) — Composition: 3 randomised trials (Tier C: no). In the head-to-head randomised trial (282 patients, 288 procedures), single-tracer magnetic-guided biopsy was non-inferior to radioisotope plus blue dye, with localisation failing in one patient per group (success 99.3%) but more nodes harvested (mean 3.3 vs 2.8) and longer procedures (33.1 vs 22.3 minutes) with the magnetic tracer. In SentimagIC (146 patients, both tracers in the same patients), per-patient detection was 99.3% (145/146) magnetic versus 98.6% (144/146) standard. The SUNRISE dose study (135 patients) found 1 mL of magnetic tracer non-inferior to higher doses and to radiotracer, with significantly less skin staining at the lowest dose. LIKELY (the treatment made no difference): magnetic-tracer sentinel-node biopsy likely detects sentinel nodes as reliably as the conventional technique in early breast cancer.
MeSH: Breast Neoplasms · Sentinel Lymph Node Biopsy · Magnetic Iron Oxide Nanoparticles · Sentinel Lymph Node · Ferric Compounds
Cards (3)
Card 1 — Magnetic single-tracer biopsy non-inferior to radioisotope + blue dye: localisation success 99.3% in both groups; more nodes (3.3 vs 2.8) and longer procedures (33.1 vs 22.3 min) with magnetic tracer (Man 2023, Ann Surg Oncol — 282 patients)
Study: Randomised controlled trial (n = 282 patients; 288 procedures)
Population: 282 patients with clinically node-negative invasive breast cancer undergoing 288 sentinel lymph node biopsy procedures (144 per group), randomised from July 2018 to August 2022 to superparamagnetic iron oxide guidance or the control technique of radioisotope and blue dye; baseline characteristics were comparable. The record identifies the tracer by its generic class (superparamagnetic iron oxide) and names no commercial product in the abstract.
Summary: Magnetic single-tracer biopsy non-inferior to radioisotope + blue dye: localisation success 99.3% in both groups; more nodes (3.3 vs 2.8) and longer procedures (33.1 vs 22.3 min) with magnetic tracer (Man 2023, Ann Surg Oncol — 282 patients)
Result: Sentinel-node localisation failed in one patient in each group (success rate 99.3%). The magnetic group had a higher mean number of sentinel nodes harvested (3.3 versus 2.8, P = 0.039) and longer mean procedure duration (33.1 versus 22.3 minutes, P = 0.01). Concordance per patient was 99.3% and per node 94.6%; 67 positive nodes were detected in 37 patients, with concordance per malignant procedure 97.3%. The authors conclude single-tracer magnetic-guided biopsy was non-inferior to the dual technique and could safely replace it.
Watch out: Non-inferiority is for node detection, not for recurrence or survival; the magnetic technique took about 11 minutes longer per procedure and removed more nodes on average.
Source: Man V et al. Annals of surgical oncology. 2023. PMID: 36849573. MeSH: Humans · Female · Breast Neoplasms · Sentinel Lymph Node · Lymph Nodes · Lymphatic Metastasis · Sentinel Lymph Node Biopsy · Lymphadenopathy · Magnetic Iron Oxide Nanoparticles · Ferric Compounds
Card 2 — Per-patient detection 99.3% (145/146) magnetic vs 98.6% (144/146) standard; every malignant node found by the standard technique was also found magnetically (Alvarado 2019, Ann Surg Oncol — SentimagIC, 146 patients)
Study: Prospective non-inferiority trial with within-patient tracer comparison (n = 146)
Population: 146 patients with clinically node-negative early-stage breast cancer at six US centres; every patient received radioisotope and isosulfan blue dye followed by an intraoperative injection of the magnetic tracer (Magtrace, formerly SiennaXP, as named in the record), so the two techniques were compared within the same patients.
Summary: Per-patient detection 99.3% (145/146) magnetic vs 98.6% (144/146) standard; every malignant node found by the standard technique was also found magnetically (Alvarado 2019, Ann Surg Oncol — SentimagIC, 146 patients)
Result: Per-patient detection was 99.3% (145/146) with the magnetic tracer and 98.6% (144/146) with the standard technique; nodal detection was 94.3% (348/369 nodes) versus 93.5% (345/369) (difference 0.8%, 95% CI lower bound −2.1%). Of 22 patients with positive sentinel nodes, 21 (95.4%) were detected by both techniques, and all malignant nodes detected by the standard technique were also identified magnetically. The authors conclude the magnetic technique is non-inferior and a viable alternative.
Watch out: Both tracers were injected in the same patients — a detection-concordance design rather than randomisation to one tracer or the other; it cannot measure differences in downstream outcomes.
Source: Alvarado MD et al. Annals of surgical oncology. 2019. PMID: 31297674. MeSH: Adult · Aged · Aged, 80 and over · Breast Neoplasms · Carcinoma, Ductal, Breast · Equivalence Trials as Topic · Female · Ferric Compounds · Follow-Up Studies · Humans · Magnetite Nanoparticles · Middle Aged · Neoplasm Staging · Predictive Value of Tests · Prospective Studies · Rosaniline Dyes · Sentinel Lymph Node · Sentinel Lymph Node Biopsy · Technetium
Card 3 — 1 mL magnetic tracer non-inferior to higher doses and to radiotracer, with significantly less skin staining (Rubio 2020, Eur J Surg Oncol — SUNRISE, 135 patients)
Study: Randomised dose-comparison non-inferiority study (n = 135)
Population: 135 patients with early-stage breast cancer (cT1–3 N0) randomised to three doses of the magnetic tracer Sienna XP (Magtrace, as named in the record) — 1 mL, 1.5 mL or 2 mL (45 per group) — each also compared with the conventional radiotracer technique, from October 2016 to August 2018.
Summary: 1 mL magnetic tracer non-inferior to higher doses and to radiotracer, with significantly less skin staining (Rubio 2020, Eur J Surg Oncol — SUNRISE, 135 patients)
Result: Sentinel-node detection with all three magnetic-tracer doses showed non-inferior rates compared with the conventional radiotracer technique (P = 0.654), and concordance in patients with positive sentinel nodes was 100% for all groups. Skin staining at one month was reported by 83 patients (70.3%) and was significantly lower in the 1 mL group (P = 0.042), remaining significantly lower at 6 months (P = 0.01); a 2 mL dose was statistically significant for skin staining in multivariate analysis, and 70% of patients felt the discoloration was not a problem.
Watch out: Skin staining affected about 70% of patients at one month — the main patient-visible cost of the magnetic tracer — and the dose comparison, not tracer versus no tracer, is what was randomised.
Source: Rubio IT et al. European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology. 2020. PMID: 32631710. MeSH: Axilla · Breast Neoplasms · Carcinoma, Ductal, Breast · Carcinoma, Intraductal, Noninfiltrating · Carcinoma, Lobular · Female · Humans · Magnetic Iron Oxide Nanoparticles · Middle Aged · Postoperative Complications · Sentinel Lymph Node · Sentinel Lymph Node Biopsy · Skin Pigmentation · Technetium Tc 99m Aggregated Albumin