SourceMed · Shelf #9385 in the ask interface

Retinal blood flow regulation by flicker light in healthy humans — 4 laboratory studies (documented N = 179): flicker dilates retinal arteries about 5% and veins about 7%, calculated venous blood flow rises up to 54%, venous oxygen saturation rises from 60% to 64% while arterial saturation stays at 98–99%, and the response is smaller in habitual smokers

Shelf #9385 · Eyes, skin, nose & allergy

PHYSIOLOGY — ESTABLISHED: in 4 human laboratory studies (documented N = 179) flicker light stimulation reproducibly dilates retinal arteries (about 5%) and veins (about 7%), raises calculated retinal venous blood flow by up to 54% and raises retinal venous oxygen saturation from 60% to 64% with arterial saturation unchanged — the neurovascular coupling response — shown by independent groups with vessel analysis, laser Doppler velocimetry and oximetry, and blunted in habitual smokers

Stamped: 2026-11-28.

Evidence published: 2003–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, how does flicker light stimulation change retinal vessel calibre, blood flow and oxygen saturation — the retinal neurovascular coupling response — and what modifies it?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED — Composition: 4 human laboratory studies (documented N = 179). Hammer 2011 (19 volunteers): flicker raised the central retinal arterial equivalent from 193 ± 20 to 202 ± 19 µm and the venous equivalent from 228 ± 20 to 242 ± 17 µm (both P < 0.0005), while venous oxygen saturation rose from 60% ± 5.7% to 64% ± 5.9% (P < 0.0005) and arterial saturation stayed at 98–99%. Garhöfer 2011 (24 smokers, 24 non-smokers): venous dilation over three flicker periods was +7.7%, +6.9% and +7.1% in non-smokers vs +4.9%, +6.3% and +5.7% in smokers (P = 0.032), and calculated venous blood flow rose up to +54% in non-smokers vs +19–26% in smokers (P = 0.013). Polak 2003 (12 men, crossover): sildenafil 100 mg raised retinal venous diameter 4.7% and blood flow 15.7% vs placebo but did not change the flicker response. Told 2014 (100 young subjects): flicker dilation did not differ by complement factor H Y402H genotype. PHYSIOLOGY — ESTABLISHED: flicker-evoked retinal vasodilation with a matching rise in flow and venous oxygenation is a reproducible human neurovascular coupling response, reduced in habitual smokers and not explained by the complement factor H risk genotype.

MeSH: Retinal Vessels · Vasodilation · Photic Stimulation · Regional Blood Flow · Oxygen · Neurovascular Coupling

Cards (4)

Card 1 — Flicker dilates both vessel types and raises venous oxygen saturation while arterial saturation is unchanged (Hammer 2011, Investigative Ophthalmology & Visual Science — 19 volunteers)

Study: Laboratory physiology study (flicker stimulation with oximetry and vessel analysis; n = 19)

Population: Nineteen healthy volunteers (mean age 26 ± 2.5 years) imaged with dual-wavelength (548 and 610 nm) fundus photography before and during luminance flicker stimulation (12.5 Hz), with retinal vessel oxygen saturation by dual-wavelength optical oximetry and diameters as central retinal arterial and venous equivalents. N = 19, printed on the face of this card.

Summary: Flicker dilates both vessel types and raises venous oxygen saturation while arterial saturation is unchanged (Hammer 2011, Investigative Ophthalmology & Visual Science — 19 volunteers)

Result: Baseline arterial and venous equivalents of 193 ± 20 µm and 228 ± 20 µm rose under flicker to maxima of 202 ± 19 µm and 242 ± 17 µm (both P < 0.0005). Arterial oxygen saturation remained unchanged at 98–99%, while venous saturation increased from 60% ± 5.7% to 64% ± 5.9% (P < 0.0005). The authors conclude the dilation indicates an elevation of retinal blood flow meeting the enhanced metabolic need of the stimulated neural retina, and the higher venous oxygenation may reflect a higher capillary oxygen concentration supporting diffusion to inner retinal tissue.

Watch out: Nineteen volunteers — N printed on the face of this card. Blood flow itself was inferred from diameter and earlier velocity work, not measured directly in this study.

Source: Hammer M et al. Retinal venous oxygen saturation increases by flicker light stimulation. Investigative ophthalmology & visual science. 2011. PMID: 20671271. Registry ID: none in the record. MeSH: Adult · Blood Flow Velocity · Female · Hemoglobins · Humans · Laser-Doppler Flowmetry · Male · Oximetry · Oxygen · Photic Stimulation · Regional Blood Flow · Retina · Retinal Artery · Retinal Vein · Vasodilation

Card 2 — The flow numbers, and the smoking contrast: calculated venous flow rises up to 54% in non-smokers, 19–26% in smokers (Garhöfer 2011, Microvascular Research — 48 adults)

Study: Laboratory physiology study (parallel-group flicker study with vessel analysis and laser Doppler velocimetry; n = 48)

Population: Twenty-four chronic smokers (28.1 ± 3.3 years) and 24 age-matched never-smoking volunteers (28.2 ± 4.0 years) in a prospective balanced parallel-group study, with flicker-induced vasodilation measured by retinal vessel analyzer and flicker-induced velocity changes in retinal veins by laser Doppler velocimetry over three 60-second flicker periods. N = 48, printed on the face of this card.

Summary: The flow numbers, and the smoking contrast: calculated venous flow rises up to 54% in non-smokers, 19–26% in smokers (Garhöfer 2011, Microvascular Research — 48 adults)

Result: In non-smokers, flicker increased retinal venous diameter by +7.7 ± 3.1%, +6.9 ± 2.9% and +7.1 ± 2.8% across the three periods; venous dilation was significantly diminished in smokers (+4.9 ± 2.4%, +6.3 ± 3.1%, +5.7 ± 3.4%; between-group P = 0.032). Calculated retinal blood flow in the measured veins rose by maxima of +54 ± 21%, +43 ± 18% and +46 ± 19% in non-smokers, significantly less in smokers (+19 ± 16%, +26 ± 14%, +24 ± 13%; P = 0.013). In retinal arteries, flicker increased diameters by 5.2 ± 3.8%, 5.8 ± 4.8% and 5.5 ± 5.6% during the three periods in non-smokers (arterial values as printed in the record). The authors set out to test, and found, impaired retinal vascular reactivity in habitual smokers.

Watch out: Forty-eight adults — N printed on the face of this card. Flow is calculated from diameter and velocity in single measured veins, not whole-retinal perfusion.

Source: Garhöfer G et al. Effect of regular smoking on flicker induced retinal vasodilatation in healthy subjects. Microvascular research. 2011. PMID: 21771603. Registry ID: none in the record. MeSH: Adult · Analysis of Variance · Biomarkers · Blood Flow Velocity · Cotinine · Female · Humans · Intraocular Pressure · Laser-Doppler Flowmetry · Male · Photic Stimulation · Prospective Studies · Regional Blood Flow · Retinal Artery · Retinal Vein · Smoking · Surveys and Questionnaires · Time Factors · Vasodilation

Card 3 — A drug probe: sildenafil raises resting venous diameter and flow but leaves the flicker response untouched (Polak 2003, Investigative Ophthalmology & Visual Science — 12 men)

Study: Laboratory physiology study (randomised placebo-controlled crossover drug probe; n = 12)

Population: Twelve healthy male volunteers in a randomised, double-masked, placebo-controlled two-way crossover study of a single 100 mg dose of sildenafil, with retinal vessel diameters by retinal vessel analyzer and retinal blood velocity by bidirectional laser Doppler flowmetry measured every 20 minutes after dosing, plus flicker responses. N = 12, printed on the face of this card.

Summary: A drug probe: sildenafil raises resting venous diameter and flow but leaves the flicker response untouched (Polak 2003, Investigative Ophthalmology & Visual Science — 12 men)

Result: Sildenafil had no effect on mean arterial pressure, pulse rate, intraocular pressure, retinal blood velocity or retinal arterial diameter. It significantly increased retinal venous diameters (4.7% ± 3.2%; P = 0.0028 vs placebo) and retinal blood flow (15.7% ± 18.0%; P = 0.029 vs placebo). It had no effect on flicker-induced vasodilation in retinal arteries or veins. The authors conclude sildenafil increases retinal venous diameter and blood flow in healthy subjects without affecting intraocular pressure or the flicker response. Sildenafil is named as published (the tested phosphodiesterase V inhibitor, single 100 mg dose).

Watch out: Twelve men — N printed on the face of this card. The blood-flow change has a wide spread (±18.0%) relative to its mean, as printed.

Source: Polak K et al. Effects of sildenafil on retinal blood flow and flicker-induced retinal vasodilatation in healthy subjects. Investigative ophthalmology & visual science. 2003. PMID: 14578411. Registry ID: none in the record. MeSH: 3',5'-Cyclic-GMP Phosphodiesterases · Adult · Blood Flow Velocity · Blood Pressure · Cross-Over Studies · Double-Blind Method · Heart Rate · Humans · Intraocular Pressure · Laser-Doppler Flowmetry · Male · Middle Aged · Phosphodiesterase Inhibitors · Piperazines · Purines · Regional Blood Flow · Retinal Vessels · Sildenafil Citrate · Sulfones · Vasodilation · Vasodilator Agents

Card 4 — A genetic probe: the complement factor H risk genotype does not alter the flicker response in the young and healthy (Told 2014, Acta Ophthalmologica — 100 subjects)

Study: Laboratory physiology study (genotype-stratified flicker study; n = 100)

Population: One hundred healthy subjects aged 18–45 years genotyped for the complement factor H Y402H variant (rs1061170), with retinal vessel calibres in response to diffuse flicker light measured by Dynamic Vessel Analyzer; one subject was excluded from evaluation because genetic analysis could not be performed. N = 100 included (99 evaluated), printed on the face of this card.

Summary: A genetic probe: the complement factor H risk genotype does not alter the flicker response in the young and healthy (Told 2014, Acta Ophthalmologica — 100 subjects)

Result: Eighteen subjects were homozygous for the risk allele C, 50 homozygous for the ancestral allele T and 31 heterozygous. Baseline diameters of retinal arteries (P = 0.39) and veins (P = 0.64) were comparable between groups, and flicker-induced vasodilation in arteries (P = 0.38) and veins (P = 0.62) was also comparable. The authors conclude homozygous young carriers of the C risk allele do not show abnormal flicker-induced vasodilation, suggesting this age-related macular degeneration risk variant does not impact neurovascular coupling in healthy subjects.

Watch out: The shelf total counts the 100 included subjects; 99 were evaluated. The finding is restricted to young healthy carriers and says nothing about the genotype's role in established macular degeneration.

Source: Told R et al. Flicker-induced retinal vasodilatation is not dependent on complement factor H polymorphism in healthy young subjects. Acta ophthalmologica. 2014. PMID: 24863099. Registry ID: none in the record. MeSH: Adolescent · Adult · Blood Flow Velocity · Blood Pressure · Complement Factor H · Female · Flicker Fusion · Genotype · Healthy Volunteers · Heart Rate · Humans · Intraocular Pressure · Male · Middle Aged · Photic Stimulation · Polymorphism, Single Nucleotide · Retinal Vessels · Vasodilation · Young Adult