SourceMed · Shelf #9389 in the ask interface

Fractional exhaled nitric oxide (FeNO) for diagnosing asthma — 4 systematic reviews and meta-analyses (4,518; 3,983; 13,747 and 2,933 participants; overlapping reviews, not summed): pooled sensitivity 65–72% and specificity 78–82% (labelled in words) in adults and mixed populations, sensitivity 79% and specificity 81% in children, with accuracy rising at higher cut-offs and in steroid-naive patients

Shelf #9389 · Lungs, breathing & sleep

MEASUREMENT ACCURACY — ruling in established, ruling out NOT ESTABLISHED: across 4 meta-analyses FeNO's pooled sensitivity was 65–72% and its pooled specificity 78–82% (sensitivity and specificity labelled in words) in adult and mixed populations — a positive result supports asthma more than a negative result excludes it — with sensitivity falling and specificity rising as the cut-off rises (at 40 ppb or more in adults: sensitivity 41%, specificity 93%), and better performance in steroid-naive patients, non-smokers and children

Stamped: 2026-11-28.

Evidence published: 2016–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does fractional exhaled nitric oxide (FeNO) measurement diagnose asthma against established reference standards (including bronchial provocation) — what are its sensitivity and specificity, and how do cut-off, age, smoking and steroid use move them?

Balance of the evidence

MEASUREMENT ACCURACY — ruling in established, ruling out NOT ESTABLISHED — Composition: 4 systematic reviews and meta-analyses (4,518, 3,983, 13,747 and 2,933 participants; the reviews overlap in their primary studies, so the counts are stated per review and never summed). Karrasch 2017 (26 studies, 4,518 participants): sensitivity 0.65 (95% CI 0.58–0.72) and specificity 0.82 (0.76–0.86) — sensitivity 65% and specificity 82% in words — with area under the curve 0.80. Guo 2016 (25 prospective studies, 3,983 subjects): pooled sensitivity 72%, specificity 78%, area under the summary curve 0.88, with diagnostic odds ratios far higher in steroid-naive patients (21.40) and chronic cough patients (35.36) than in corticosteroid users (4.47) or allergic rhinitis patients (2.99). Wang 2018 (43 studies, 13,747 patients): in adults, moving the cut-off from under 20 to 40 ppb or more moved sensitivity from 0.80 to 0.41 and specificity from 0.64 to 0.93. Tang 2019 (8 studies, 2,933 children): pooled sensitivity 0.79, specificity 0.81.

MeSH: Asthma · Nitric Oxide · Breath Tests · Sensitivity and Specificity

Cards (4)

Card 1 — The reference-standard review: sensitivity 65%, specificity 82% (labelled in words) against established diagnosis including provocation (Karrasch 2017, Thorax — 26 studies, 4,518 participants)

Study: Systematic review and diagnostic meta-analysis (26 studies; 4,518 participants)

Population: Systematic review and diagnostic meta-analysis of FeNO measurement against established reference standards for asthma (Medline, Embase and Scopus to 29 November 2015), including 26 studies with 4,518 participants (median 113 per study).

Summary: The reference-standard review: sensitivity 65%, specificity 82% (labelled in words) against established diagnosis including provocation (Karrasch 2017, Thorax — 26 studies, 4,518 participants)

Result: The overall sensitivity in the meta-analysis was 0.65 (95% CI 0.58 to 0.72) and the overall specificity 0.82 (0.76 to 0.86) — that is, sensitivity 65% and specificity 82%, labelled in words — with a diagnostic odds ratio of 9.23 (6.55 to 13.01) and area under the curve 0.80 (0.77 to 0.85). In meta-regression, higher cut-off values were associated with increasing specificity (odds ratio 1.46 per 10 ppb increase in cut-off) with no association with sensitivity; sensitivity varied significantly between FeNO devices, specificity did not. The authors conclude FeNO has fair accuracy for diagnosing asthma, with higher potential for ruling in than ruling out the diagnosis.

Watch out: Proportions and percentages are both printed so the pair is never bare. The device-dependence of sensitivity means a pooled figure does not transfer automatically to every analyser.

Source: Karrasch S et al. Accuracy of FENO for diagnosing asthma: a systematic review. Thorax. 2017. PMID: 27388487. Registry ID: none in the record. MeSH: Asthma · Breath Tests · Bronchial Provocation Tests · Diagnosis, Differential · Forced Expiratory Volume · Humans · Nitric Oxide

Card 2 — Prospective studies only: sensitivity 72%, specificity 78% (labelled in words), and far better in steroid-naive and chronic-cough patients (Guo 2016, Journal of Asthma — 25 studies, 3,983 subjects)

Study: Systematic review and meta-analysis of prospective studies (25 studies; 3,983 subjects)

Population: Systematic review and meta-analysis of prospective studies of FeNO for asthma diagnosis (searches to July 2014), including 25 studies with 3,983 subjects.

Summary: Prospective studies only: sensitivity 72%, specificity 78% (labelled in words), and far better in steroid-naive and chronic-cough patients (Guo 2016, Journal of Asthma — 25 studies, 3,983 subjects)

Result: Pooled sensitivity was 72% (95% CI 70–74%) and pooled specificity 78% (95% CI 76–80%) — sensitivity and specificity labelled in words — with a diagnostic odds ratio of 15.92 (95% CI 10.70–23.68) and an area under the summary receiver operating characteristic curve of 0.88. Subgroup diagnostic odds ratios were 4.47 (95% CI 3.39–5.90) in corticosteroid users, 21.40 (15.38–29.76) in steroid-naive patients, 19.84 (15.63–25.19) in non-smokers, 5.41 (2.97–9.86) in smokers, 35.36 (23.90–52.29) in chronic cough patients and 2.99 (0.85–10.45) in allergic rhinitis patients. The authors conclude FeNO is accurate for asthma diagnosis in steroid-naive and non-smoking patients, particularly those with chronic cough.

Watch out: The allergic-rhinitis subgroup's diagnostic odds ratio confidence interval crosses 1 (0.85–10.45), as printed — FeNO performed no better than chance there in this analysis.

Source: Guo Z et al. Diagnostic accuracy of fractional exhaled nitric oxide in asthma: a systematic review and meta-analysis of prospective studies. The Journal of asthma. 2016. PMID: 26796787. Registry ID: none in the record. MeSH: Asthma · Breath Tests · Exhalation · Humans · Nitric Oxide · Prospective Studies · Reproducibility of Results

Card 3 — The cut-off ladder in 13,747 patients: at 40 ppb or more, sensitivity 41% and specificity 93% (labelled in words) in adults (Wang 2018, Mayo Clinic Proceedings — 43 studies)

Study: Systematic review and meta-analysis (43 studies; 13,747 patients)

Population: Systematic review of FeNO diagnostic accuracy in patients aged 5 years and older with suspected asthma (databases to 4 April 2017), including 43 studies with 13,747 patients, analysed with hierarchical summary receiver operating characteristic models; the review's PROSPERO identifier is printed in its record (CRD42016047887).

Summary: The cut-off ladder in 13,747 patients: at 40 ppb or more, sensitivity 41% and specificity 93% (labelled in words) in adults (Wang 2018, Mayo Clinic Proceedings — 43 studies)

Result: In adults, at FeNO cut-offs of under 20, 20–29, 30–39 and 40 or more parts per billion, sensitivities were 0.80, 0.69, 0.53 and 0.41 and specificities were 0.64, 0.78, 0.85 and 0.93 — in words, sensitivity fell from 80% to 41% while specificity rose from 64% to 93% as the cut-off rose. In children, at cut-offs under 20 and 20–29 ppb, sensitivities were 0.78 and 0.61 and specificities 0.79 and 0.89. A positive result raised the post-test odds of asthma 2.80- to 7.00-fold depending on cut-off. Accuracy was modestly better in corticosteroid-naive patients, children and non-smokers. The authors conclude FeNO has moderate accuracy to diagnose asthma from age 5. PROSPERO registration CRD42016047887 is printed in the record and reproduced here.

Watch out: No single sensitivity/specificity pair exists for FeNO — the pair is a function of the cut-off, and this card's ladder is the reason the stamp names no universal pair.

Source: Wang Z et al. The Diagnostic Accuracy of Fractional Exhaled Nitric Oxide Testing in Asthma: A Systematic Review and Meta-analyses. Mayo Clinic proceedings. 2018. PMID: 29275031. Registry ID: none in the record. MeSH: Asthma · Breath Tests · Dimensional Measurement Accuracy · Humans · Nitric Oxide

Card 4 — Children alone: sensitivity 79%, specificity 81% (labelled in words) (Tang 2019, Clinical Reviews in Allergy & Immunology — 8 studies, 2,933 subjects)

Study: Systematic review and meta-analysis, children (8 studies; 2,933 subjects)

Population: Systematic review and meta-analysis of FeNO for diagnosing childhood asthma (databases to 31 March 2016), including 8 studies with 2,933 subjects, pooled with a bivariate model.

Summary: Children alone: sensitivity 79%, specificity 81% (labelled in words) (Tang 2019, Clinical Reviews in Allergy & Immunology — 8 studies, 2,933 subjects)

Result: Pooled sensitivity was 0.79 (95% CI 0.64–0.89) and pooled specificity 0.81 (95% CI 0.66–0.90) — sensitivity 79% and specificity 81%, labelled in words — with a diagnostic odds ratio of 16.52 (95% CI 7.64–35.71) and an area under the summary receiver operating curve of 0.87 (95% CI 0.84–0.90). The authors conclude FeNO achieves a moderate diagnostic performance for asthma in children, against a reference standard of clinical history, examination and respiratory function testing.

Watch out: The confidence intervals are wide (sensitivity 0.64–0.89), as printed, reflecting only 8 studies; the childhood estimate is less precise than the adult ladders on this shelf.

Source: Tang S et al. Fractional Exhaled Nitric Oxide for the Diagnosis of Childhood Asthma: a Systematic Review and Meta-analysis. Clinical reviews in allergy & immunology. 2019. PMID: 27444490. Registry ID: none in the record. MeSH: Asthma · Child · Child, Preschool · Exhalation · Humans · Nitric Oxide · Publication Bias · Reproducibility of Results · Sensitivity and Specificity · Spirometry