SourceMed · Shelf #9390 in the ask interface
Heel quantitative ultrasound for fracture prediction and osteoporosis identification — 4 meta-analyses (46,124 and 47,300 individuals in the prospective pools; 68,906 women and men in the updated pool; overlapping reviews, not summed): each standard-deviation decrease raises hip fracture risk about 1.6–2.3-fold (relative), yet for identifying DXA osteoporosis at a T-score cut-off of −1 the sensitivity is 79% and specificity 58% (labelled in words)
Shelf #9390 · Bones & joints
PREDICTIVE PERFORMANCE — established for fracture risk stratification, NOT ESTABLISHED for identifying DXA-defined osteoporosis in an individual: prospective meta-analyses give gradients of risk of 1.42–1.45 per standard-deviation decrease for osteoporotic fracture and 1.60–1.69 for hip fracture (relative measures, with cohort absolute fracture counts printed on the cards), independent of DXA in adjusted analyses, while against DXA itself a quantitative-ultrasound T-score cut-off of −1 gives sensitivity 79% and specificity 58% (labelled in words) — too weak to stand in for a DXA diagnosis
Stamped: 2026-11-28.
Evidence published: 2006–2015.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How well does heel (calcaneal) quantitative ultrasound do two different jobs — predicting future fractures prospectively, and identifying osteoporosis as defined by DXA T-score −2.5 or lower — and are the two performances the same?
Balance of the evidence
PREDICTIVE PERFORMANCE — established for fracture risk stratification, NOT ESTABLISHED for identifying DXA-defined osteoporosis in an individual — Composition: 4 meta-analyses of prospective cohorts and diagnostic studies (46,124 individuals with 3,018 incident fractures; about 47,300 individuals with over 2,350 fractures; 55,164 women and 13,742 men with 279,124 person-years; and 25 diagnostic studies whose record states no pooled N; the reviews overlap, so counts are stated per review and never summed). McCloskey 2015: gradient of risk per standard-deviation decrease was 1.45 (95% CI 1.40–1.51) for broadband ultrasound attenuation and 1.42 (1.36–1.47) for speed of sound for osteoporotic fracture, and 1.69 (1.56–1.82) and 1.60 (1.48–1.72) for hip fracture — relative measures; 787 of the fractures were hip fractures. Moayyeri 2012: relative risk of hip fracture per standard-deviation decrease was 1.69 for attenuation, 1.96 for speed of sound, 2.26 for stiffness index and 1.99 for the quantitative ultrasound index, and attenuation stayed predictive after adjustment for hip bone density (relative risk 1.34, 95% CI 1.22–1.49). Marín 2006: relative risks for overall fracture in women were 1.55 (attenuation), 1.63 (speed of sound) and 1.74 (index). Nayak 2006, against DXA: at a quantitative-ultrasound T-score cut-off of −1, sensitivity was 79% and specificity 58% (labelled in words).
MeSH: Calcaneus · Ultrasonography · Osteoporotic Fractures · Hip Fractures · Risk Assessment · Predictive Value of Tests
Cards (4)
Card 1 — Individual-level prospective pool: gradient of risk 1.45 for osteoporotic fracture, 1.69 for hip fracture per standard-deviation decrease (McCloskey 2015, Osteoporosis International — 46,124 individuals, 3,018 fractures)
Study: Individual-level meta-analysis of prospective cohorts (9 cohorts; 46,124 individuals)
Population: Individual-level meta-analysis of 9 prospective cohorts from Asia, Europe and North America: 46,124 men and women (mean age 70 years, range 20–100) with baseline heel broadband ultrasound attenuation (BUA) and speed of sound (SOS), followed for 214,000 person-years, during which 3,018 osteoporotic fractures (787 hip fractures) occurred — the absolute fracture counts are printed here alongside the relative gradients, per this shelf's wording rule.
Summary: Individual-level prospective pool: gradient of risk 1.45 for osteoporotic fracture, 1.69 for hip fracture per standard-deviation decrease (McCloskey 2015, Osteoporosis International — 46,124 individuals, 3,018 fractures)
Result: The summary gradient of risk (hazard ratio per 1 standard-deviation decrease, adjusted for age and time since baseline) for osteoporotic fracture was 1.45 (95% CI 1.40–1.51) for BUA and 1.42 (1.36–1.47) for SOS; for hip fracture the gradients were 1.69 (1.56–1.82) and 1.60 (1.48–1.72). These are relative measures. The gradient was significantly higher at lower baseline values (P < 0.001), the same for men and women and all ages, but decreased with time since measurement (for BUA, 1.51 at 1 year vs 1.36 at 5 years). The authors conclude quantitative ultrasound is an independent predictor of fracture, particularly at low values.
Watch out: Gradients of risk are relative and are printed with the cohort's absolute fracture counts (3,018 of 46,124 over 214,000 person-years) on this card. Prediction weakened with time since the baseline scan, as printed.
Source: McCloskey EV et al. Predictive ability of heel quantitative ultrasound for incident fractures: an individual-level meta-analysis. Osteoporosis international. 2015. PMID: 25690339. Registry ID: none in the record. MeSH: Age Factors · Calcaneus · Follow-Up Studies · Hip Fractures · Humans · Osteoporosis · Osteoporotic Fractures · Predictive Value of Tests · Risk Assessment · Ultrasonography
Estimate type: adjusted estimate, as stated in the card.
Card 2 — Updated prospective pool: stiffness index carries the largest hip-fracture relative risk, 2.26 per standard-deviation decrease (Moayyeri 2012, Osteoporosis International — 21 studies, 68,906 people)
Study: Meta-analysis of prospective studies (21 studies; 68,906 participants)
Population: Inverse-variance random-effects meta-analysis of prospective studies with baseline heel quantitative ultrasound and follow-up fracture outcomes: 21 studies including 55,164 women and 13,742 men, with 279,124 person-years of follow-up.
Summary: Updated prospective pool: stiffness index carries the largest hip-fracture relative risk, 2.26 per standard-deviation decrease (Moayyeri 2012, Osteoporosis International — 21 studies, 68,906 people)
Result: All four parameters were associated with fracture risk. For hip fracture, the relative risk per 1 standard-deviation decrease was 1.69 (95% CI 1.43–2.00) for broadband ultrasound attenuation, 1.96 (1.64–2.34) for speed of sound, 2.26 (1.71–2.99) for stiffness index and 1.99 (1.49–2.67) for the quantitative ultrasound index — relative measures, printed as reported. Validated devices from different manufacturers predicted with similar performance, and prediction was similar in men and women. In studies adjusting for hip bone mineral density, attenuation remained significantly associated with fracture (relative risk per standard deviation 1.34, 95% CI 1.22–1.49). There was marked heterogeneity among studies for hip and clinical fractures. The authors conclude heel quantitative ultrasound with validated devices predicts different fracture outcomes in older men and women, independently of DXA estimates.
Watch out: This pool overlaps the cohorts in the McCloskey and Marín cards; its participant count is not added to theirs. Device names are given in the record only by parameter and validation status, not by maker.
Source: Moayyeri A et al. Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis. Osteoporosis international. 2012. PMID: 22037972. Registry ID: none in the record. MeSH: Absorptiometry, Photon · Aged · Bone Density · Calcaneus · Female · Humans · Male · Middle Aged · Osteoporosis · Osteoporosis, Postmenopausal · Osteoporotic Fractures · Prognosis · Risk Assessment · Ultrasonography
Card 3 — The earlier prospective pool in women: relative risks 1.55–1.74 per standard-deviation decrease across parameters (Marín 2006, Journal of Bone and Mineral Research — about 47,300 individuals, over 2,350 fractures)
Study: Meta-analysis of prospective cohorts (14 populations; about 47,300 individuals)
Population: Meta-analysis of 14 prospective study populations (about 47,300 individuals, 85.4% women; about 124,000 person-years) with baseline quantitative ultrasound — at the heel in 11 studies — and over 2,350 incident fractures, including 653 hip, 529 forearm and 386 humeral fractures, printed here as the absolute counts behind the relative estimates.
Summary: The earlier prospective pool in women: relative risks 1.55–1.74 per standard-deviation decrease across parameters (Marín 2006, Journal of Bone and Mineral Research — about 47,300 individuals, over 2,350 fractures)
Result: In women, the estimated relative risk of overall fracture for each standard-deviation decrease was 1.55 (95% CI 1.35–1.78) for broadband ultrasound attenuation, 1.63 (1.37–1.93) for speed of sound and 1.74 (1.39–2.17) for the quantitative ultrasound index/stiffness index — relative measures. Risk estimates were similar or slightly higher for hip fractures and low-energy trauma fractures, and humeral and forearm/wrist fractures were also related to lower values. There was no significant heterogeneity among studies. The authors conclude quantitative ultrasound is associated with non-spinal fracture risk in older women to a similar degree as DXA, and may be a valid alternative for fracture-risk evaluation where DXA is not accessible.
Watch out: Estimates are for women, who made up 85.4% of the pool; the men's evidence is carried by the McCloskey and Moayyeri cards. Two of the 14 populations measured the patella or phalanx rather than the heel, as printed.
Source: Marín F et al. Relationship between bone quantitative ultrasound and fractures: a meta-analysis. Journal of bone and mineral research. 2006. PMID: 16813534. Registry ID: none in the record. MeSH: Age Factors · Bone and Bones · Female · Follow-Up Studies · Fractures, Bone · Humans · Male · Meta-Analysis as Topic · Prospective Studies · Risk Factors · Ultrasonography
Card 4 — The other job — finding DXA osteoporosis: at a T-score cut-off of −1, sensitivity 79% and specificity 58% (labelled in words) (Nayak 2006, Annals of Internal Medicine — 25 studies)
Study: Diagnostic meta-analysis against DXA (25 studies; pooled N not stated in the record)
Population: Meta-analysis of English-language studies (searches to 2005) evaluating calcaneal quantitative ultrasound against DXA T-scores of −2.5 or less at the hip or spine as the reference standard for osteoporosis; 25 studies met the inclusion criteria (the record states no pooled participant number).
Summary: The other job — finding DXA osteoporosis: at a T-score cut-off of −1, sensitivity 79% and specificity 58% (labelled in words) (Nayak 2006, Annals of Internal Medicine — 25 studies)
Result: For the quantitative ultrasound index T-score cut-off of −1, sensitivity was 79% (95% CI 69% to 86%) and specificity was 58% (CI 44% to 70%) — sensitivity and specificity labelled in words — for identifying individuals with DXA T-scores of −2.5 or less. At a cut-off of 0, sensitivity improved to 93% (CI 87% to 97%) but specificity fell to 24% (CI 10% to 47%). At a pretest probability of 22% (a 65-year-old woman at average risk, as printed), the post-test probability of DXA-determined osteoporosis was 34% (CI 26% to 41%) after a positive result and 10% (CI 5% to 12%) after a negative result at the −1 cut-off. Other parameters (including broadband ultrasound attenuation) gave similar estimates. The authors note the small number of studies limited analysis of heterogeneity.
Watch out: This card answers a different question from the other three: agreement with a DXA category, not fracture prediction. The record states no pooled N, so none is claimed, and this card contributes no N to any total.
Source: Nayak S et al. Meta-analysis: accuracy of quantitative ultrasound for identifying patients with osteoporosis. Annals of internal medicine. 2006. PMID: 16754925. Registry ID: none in the record. MeSH: Absorptiometry, Photon · Aged · Aged, 80 and over · Bias · Calcaneus · Female · Hip · Humans · Male · Middle Aged · Osteoporosis · Reference Standards · Sensitivity and Specificity · Spine · Ultrasonography