SourceMed · Shelf #9410 in the ask interface
Endoscopic ultrasound tissue sampling of solid pancreatobiliary masses: do needle design and suction technique matter? — 3 randomised trials (458 patients): Franseen and fork-tip biopsy needles tied on accuracy (85.3% versus 90.7%), two passes reached sensitivity above 90% with either needle, and wet suction yielded more tissue cores than slow pull (71.4% versus 61.4%) with equal accuracy
Shelf #9410 · Liver & gut
POSSIBLE (the treatment made no difference — to diagnostic accuracy: the two modern biopsy needle designs tied on histologic yield and accuracy in a 134-patient randomised trial, sensitivity (labelled in words) after two passes was about 90% with either needle design in a 114-patient trial, and wet suction produced more intact cores than slow pull without improving accuracy in a 210-patient crossover trial)
Stamped: 2026-11-28.
Evidence published: 2021–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients undergoing endoscopic-ultrasound-guided fine-needle biopsy of solid pancreatobiliary masses, do the choice of biopsy needle (Franseen versus fork-tip designs) and the suction technique (wet suction versus slow pull) change tissue yield, sensitivity (labelled in words) for malignancy, or diagnostic accuracy?
Balance of the evidence
POSSIBLE (the treatment made no difference — to diagnostic accuracy) — Composition: 3 randomised trials, 458 patients (134 + 114 + 210). Franseen versus fork-tip needles (150 lesions in 134 patients): adequate histologic samples in 94.7% versus 96.0%, diagnostic accuracy of histologic analysis 85.3% versus 90.7% (P = 0.45), and of combined cytologic and histologic analysis 86.7% versus 92.0% — no significant difference on any endpoint. Per-pass performance (114 patients): four passes detected malignancy with sensitivity 93.6% (Franseen) versus 98% (3-prong tip) — sensitivity labelled in words — and two passes already gave sensitivity of 91.5% and 90.2% respectively. Wet suction versus slow pull (210 patients, crossover): a tissue core was retrieved in 71.4% versus 61.4% of passes (P = 0.03) and tissue integrity was higher with wet suction, but blood contamination was also higher (P < 0.001) and diagnostic accuracy and adequate tumour fraction did not differ. POSSIBLE (the treatment made no difference): within modern fine-needle biopsy practice, neither needle geometry nor suction technique has been shown to change diagnostic accuracy; two passes suffice for sensitivity above 90%, and technique choices can rest on handling and specimen preferences.
MeSH: Endoscopic Ultrasound-Guided Fine Needle Aspiration · Pancreatic Neoplasms · Needles · Equipment Design · Suction · Specimen Handling
Cards (3)
Card 1 — Franseen versus fork-tip: histologic yield 94.7% versus 96.0%, accuracy 85.3% versus 90.7% — a tie (Ashat 2021, Gastrointestinal Endoscopy — 134 patients, 150 lesions)
Study: Randomised controlled trial (134 patients; 150 lesions)
Population: Randomised controlled trial in 134 patients with 150 lesions (75 pancreatic, 75 other solid lesions in and around the gastrointestinal tract), randomised 1:1 between endoscopic-ultrasound-guided fine-needle biopsy with a Franseen needle and a fork-tip needle; primary endpoint was yield of adequate histologic tissue samples, secondary endpoint diagnostic accuracy.
Summary: Franseen versus fork-tip: histologic yield 94.7% versus 96.0%, accuracy 85.3% versus 90.7% — a tie (Ashat 2021, Gastrointestinal Endoscopy — 134 patients, 150 lesions)
Result: There was no statistically significant difference in adequate histologic samples (71 of 75, 94.7%, Franseen versus 72 of 75, 96.0%, fork-tip; absolute difference −1.3 percentage points, 95% CI −8.1 to 5.4), in diagnostic accuracy of histologic analysis (64 of 75, 85.3%, versus 68 of 75, 90.7%; P = 0.45), or in accuracy of combined cytologic and histologic analysis (65 of 75, 86.7%, versus 69 of 75, 92%; P = 0.43). The authors conclude both needles achieved a high yield of histologic tissue and high diagnostic accuracy, with no significant difference in performance.
Watch out: Half the lesions were not pancreatic, and a tie in a 150-lesion trial excludes only large differences; small accuracy gaps between needle designs remain possible.
Source: Ashat M et al. Randomized controlled trial comparing the Franseen needle with the Fork-tip needle for EUS-guided fine-needle biopsy. Gastrointestinal endoscopy. 2021. PMID: 32526235. Registry ID: NCT03672032 (clinical trial registration number in the record). MeSH: Endoscopic Ultrasound-Guided Fine Needle Aspiration · Equipment Design · Humans · Needles · Pancreas · Pancreatic Neoplasms
Card 2 — Two passes were enough: sensitivity 91.5% and 90.2% by pass two with either needle (Mohamadnejad 2023, Gastrointestinal Endoscopy — 114 patients)
Study: Randomised controlled trial (n = 114)
Population: Randomised trial in 114 patients referred for endoscopic ultrasound evaluation of solid pancreatobiliary mass lesions, randomised between biopsy sampling with a Franseen needle and a 3-prong tip needle with asymmetric cutting surfaces; four passes were taken from each mass, specimens were read by two pathologists blinded to needle type, and the final diagnosis rested on biopsy pathology, surgery, or at least 6 months of follow-up (98 patients, 86%, had malignancy; 16, 14%, benign disease).
Summary: Two passes were enough: sensitivity 91.5% and 90.2% by pass two with either needle (Mohamadnejad 2023, Gastrointestinal Endoscopy — 114 patients)
Result: Four passes detected malignancy with a sensitivity of 93.6% (95% CI 82.5–98.7) for the Franseen needle (44 of 47) and 98% (95% CI 89.6–99.9) for the 3-prong needle (50 of 51; P = 0.35) — sensitivity labelled in words. After two passes, sensitivity was already 91.5% (95% CI 79.6–97.6) and 90.2% (95% CI 78.6–96.7) respectively, and cumulative sensitivity at pass 3 was 93.6% and 96.1%. Franseen samples had significantly higher cellularity (P < 0.01) with no difference in bloodiness. The authors conclude two passes are required to detect malignancy with at least 90% sensitivity with either needle.
Watch out: Sensitivity figures come from a population in which 86% of masses proved malignant; in a lower-prevalence setting the same needles would generate more false-positive concern per true case found, and 'suspicious' readings were counted as nondiagnostic in the primary analysis.
Source: Mohamadnejad M et al. Comparing per-pass performance of 2 types of needles for EUS-guided fine-needle biopsy sampling of pancreatobiliary masses in a randomized trial. Gastrointestinal endoscopy. 2023. PMID: 37098399. Registry ID: none cited in full in the record. MeSH: Humans · Pancreatic Neoplasms · Endoscopic Ultrasound-Guided Fine Needle Aspiration · Specimen Handling
Card 3 — Wet suction won more cores (71.4% versus 61.4%) but not more accuracy (Crinò 2023, Endoscopy — 210 patients)
Study: Randomised crossover trial (n = 210)
Population: Multicentre, randomised, single-blind, crossover trial in 210 patients with solid lesions of at least 1 cm (146 pancreatic, 64 nonpancreatic) undergoing endoscopic-ultrasound-guided fine-needle biopsy with 22G fork-tip or Franseen-type needles: four passes per lesion, alternating wet-suction and slow-pull techniques in randomised order; primary outcome was histological yield (a sample containing an intact tissue piece of at least 550 µm).
Summary: Wet suction won more cores (71.4% versus 61.4%) but not more accuracy (Crinò 2023, Endoscopy — 210 patients)
Result: A tissue core was retrieved in 150 (71.4%) cases with wet suction and 129 (61.4%) with slow pull (P = 0.03); mean tissue integrity score was higher with wet suction (P = 0.02), as was blood contamination of samples (P < 0.001). In the pancreatic and nonpancreatic subgroups, core rate and integrity did not differ significantly between techniques, while blood contamination remained higher with wet suction. Diagnostic accuracy and the rate of samples with adequate tumour fraction did not differ between the techniques.
Watch out: More and bloodier cores are a specimen-quality outcome, not a patient outcome: the trial's own accuracy endpoint — the one that changes management — was equal.
Source: Crinò SF et al. Wet-suction versus slow-pull technique for endoscopic ultrasound-guided fine-needle biopsy: a multicenter, randomized, crossover trial. Endoscopy. 2023. PMID: 35915956. Registry ID: none in the record. MeSH: Humans · Pancreatic Neoplasms · Endoscopic Ultrasound-Guided Fine Needle Aspiration · Suction · Cross-Over Studies · Single-Blind Method · Pancreas