SourceMed · Shelf #9457 in the ask interface

Displaced olecranon fractures in adults: plate fixation versus tension-band wiring — 1 randomised trial (67 patients) and a review of 8 randomised trials (399 patients): function tied at 1 year (DASH 8.5 versus 12.8), complications split by kind

Shelf #9457 · Bones & joints

SPLIT (by complication) — plate fixation and tension-band wiring tied on DASH at 1 year (8.5 versus 12.8, P = 0.315) in the randomised trial (67 patients); tension-band wiring brought more symptomatic metalwork and removals (50% versus 22%), while the trial's infections and revision surgeries occurred only after plate fixation

Stamped: 2026-11-28.

Evidence published: 2017–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with a simple isolated displaced olecranon fracture, does plate fixation beat tension-band wiring on patient-reported function — and how do complications and implant removal compare?

Balance of the evidence

SPLIT (by complication) — Composition: 1 prospective randomised trial (67 patients) and 1 systematic review of randomised trials (8 trials, 399 patients; the review pool includes the carded trial's literature, so counts are stated per card and not summed). Duckworth 2017: at 1 year the DASH score was 12.8 after tension-band wiring and 8.5 after plate fixation (P = 0.315) (the treatment made no difference to function), with no significant differences in range of motion, Broberg and Morrey score or Mayo Elbow Score at any point. Complication rates were higher after tension-band wiring (63% versus 38%; P = 0.042), driven by metalwork removal in symptomatic patients (50.0% versus 22%); but all four infections (0% versus 13%) and all three revision surgeries occurred in the plate group. Matar 2018 (8 trials, 399 patients): modified tension-band techniques and plate fixation each reported higher metalwork prominence with standard tension-band wiring, and more serious complications with plate fixation in the two plate-comparison trials. SPLIT (by complication): function is tied; the choice trades frequent, lesser metalwork problems after wiring against rarer, more serious complications after plating.

MeSH: Olecranon Process · Ulna Fractures · Bone Plates · Bone Wires · Fracture Fixation, Internal

Cards (2)

Card 1 — Function tied at 1 year (DASH 12.8 versus 8.5); removals 50% after wiring versus 22% after plating, infections only after plating (Duckworth 2017, Journal of Bone and Joint Surgery American — randomised trial, 67 patients)

Study: Primary randomised trial (n = 67)

Population: Sixty-seven patients aged 16 to under 75 years with an acute isolated displaced olecranon fracture at a single centre, randomised to tension-band wiring (34 patients) or plate fixation (33 patients) and evaluated at 6 weeks, 3 and 6 months and 1 year; the 1-year follow-up rate was 85% (57 patients), with 56 completing the DASH. The primary outcome was the DASH score at 1 year. N = 67, as printed in the record.

Summary: Function tied at 1 year (DASH 12.8 versus 8.5); removals 50% after wiring versus 22% after plating, infections only after plating (Duckworth 2017, Journal of Bone and Joint Surgery American — randomised trial, 67 patients)

Result: The DASH score improved significantly over the year in both groups (P < 0.001). At 1 year the DASH score for the tension-band group (12.8) did not differ significantly from the plate group (8.5) (P = 0.315) (the treatment made no difference to the primary outcome), and the groups did not differ in range of motion, Broberg and Morrey score, Mayo Elbow Score or DASH at any assessment point (all P ≥ 0.05). Complication rates were significantly higher in the tension-band group (63% compared with 38%; P = 0.042), predominantly because of a higher rate of metalwork removal in symptomatic patients (50.0% compared with 22%; P = 0.021). Four infections occurred, all in the plate group (0% versus 13%; P = 0.114), as did 3 revision surgeries (0% versus 9.4%; P = 0.238).

Watch out: Simple isolated fractures in patients under 75 only — comminuted fractures and older patients are outside this trial; the age of the tension-band group was lower at baseline, as the record notes.

Source: Duckworth AD et al. Plate Versus Tension-Band Wire Fixation for Olecranon Fractures: A Prospective Randomized Trial. Journal of Bone and Joint Surgery, American Volume. 2017. PMID: 28763412. Registry ID: none in the record. MeSH: Adult · Bone Plates · Bone Wires · Disability Evaluation · Female · Follow-Up Studies · Fracture Fixation, Internal · Humans · Male · Middle Aged · Olecranon Process · Prospective Studies · Recovery of Function · Ulna Fractures

Card 2 — Across 8 randomised trials (399 patients), standard wiring keeps the metalwork-prominence problem (Matar 2018, Journal of Long-Term Effects of Medical Implants — systematic review of RCTs)

Study: Synthesis (systematic review of 8 randomised trials, 399 patients)

Population: Systematic review of randomised controlled trials of surgical treatments for olecranon fractures in adults, focused on metalwork prominence: 8 trials involving 399 patients (220 men and 179 women) — 6 randomised and 2 quasi-randomised trials; standard tension-band wiring was the control in 7 trials, against modified plate fixation or modified wiring techniques. Counts are as printed in the record; the pool overlaps the trial carded above and is not summed with it.

Summary: Across 8 randomised trials (399 patients), standard wiring keeps the metalwork-prominence problem (Matar 2018, Journal of Long-Term Effects of Medical Implants — systematic review of RCTs)

Result: For trials comparing standard with modified tension-band wiring (5 trials), outcomes were similar, but with a higher rate of metalwork prominence with standard wiring. Two trials compared plate fixation with tension-band wiring and reported higher metalwork prominence with wiring but more serious complications with plate fixation. One trial compared locking plate with memory connector plate fixation, with no significant differences. The reviewers conclude tension-band wiring remains the standard technique, with a high rate of symptomatic metalwork prominence.

Watch out: The review reports directions and rates of metalwork prominence rather than pooled effect sizes in its abstract, and two of its eight trials are quasi-randomised — it widens the base for the prominence finding without sharpening the function comparison.

Source: Matar HE et al. Metalwork Prominence and Operative Interventions for Treating Olecranon Fractures: Systematic Review of Randomised Controlled Trials. Journal of Long-Term Effects of Medical Implants. 2018. PMID: 31002625. Registry ID: none in the record. MeSH: Bone Plates · Bone Wires · Fracture Fixation, Internal · Fractures, Bone · Humans · Olecranon Process · Randomized Controlled Trials as Topic