Ramped position versus sniffing position for endotracheal intubation of critically ill adults — 1 multicentre randomised trial (260 patients): no oxygenation benefit (lowest saturation 93% versus 92%), with a worse glottic view and fewer first-attempt successes in the ramped position

Shelf #9469 · Critical care & sepsis

POSSIBLE (the treatment made no difference) — for oxygenation, with harm signals on view and first attempt, in a single trial: in 260 critically ill adults, the median lowest oxygen saturation was 93% ramped versus 92% sniffing (P = 0.27), while grade III or IV glottic view was 25.4% versus 11.5%, difficult intubation 12.3% versus 4.6%, and first-attempt success 76.2% versus 85.4% — all favouring the sniffing position

Stamped: 2026-11-28.

Evidence published: 2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In critically ill adults undergoing endotracheal intubation, does the ramped position (head of bed elevated to 25 degrees) improve oxygenation and intubation success compared with the sniffing position?

Balance of the evidence

POSSIBLE (the treatment made no difference) — on the primary oxygenation outcome, in one multicentre trial; the secondary outcomes point against ramping in this setting. Composition: 1 randomised trial, 260 adults intubated by pulmonary and critical care fellows in 4 US intensive care units (Semler 2017), comparing the ramped position (head of bed elevated to 25°) with the sniffing position (torso supine, neck flexed, head extended). The median lowest arterial oxygen saturation between induction and 2 minutes after intubation was 93% (interquartile range 84% to 99%) ramped versus 92% (interquartile range 79% to 98%) sniffing (P = 0.27) — the treatment made no difference to oxygenation. The ramped position increased grade III or IV glottic view (25.4% versus 11.5%, P = 0.01), increased difficult intubation (12.3% versus 4.6%, P = 0.04), and decreased first-attempt intubation (76.2% versus 85.4%, P = 0.02). The stamp is POSSIBLE and Tier C because this is a single trial in fellow-performed ICU intubations; operating-room and obese-patient positioning evidence is a different question and is not carded here. POSSIBLE (the treatment made no difference): the ramped position does not improve oxygenation during intubation of critically ill adults, and in the single trial it worsened the glottic view and first-attempt success.

MeSH: Patient Positioning · Intubation, Intratracheal · Critical Illness · Laryngoscopy · Hypoxia

Cards (1)

Card 1 — Ramping did not improve oxygenation — 93% versus 92% lowest saturation — and worsened the view (Semler 2017, Chest — 260 patients)

Study: Primary trial report (multicentre randomised trial; n = 260)

Population: 260 critically ill adults undergoing endotracheal intubation by pulmonary and critical care medicine fellows in 4 intensive care units (July 2015 to July 2016), randomised to the ramped position (head of the bed elevated to 25°) or the sniffing position (torso supine, neck flexed, head extended). The primary outcome was the lowest arterial oxygen saturation between induction and 2 minutes after intubation. N = 260, printed on the face of this card.

Summary: Ramping did not improve oxygenation — 93% versus 92% lowest saturation — and worsened the view (Semler 2017, Chest — 260 patients)

Result: The median lowest arterial oxygen saturation was 93% (interquartile range 84% to 99%) with the ramped position versus 92% (interquartile range 79% to 98%) with the sniffing position (P = 0.27) — the treatment made no difference to the primary outcome. The ramped position appeared to increase the incidence of grade III or IV glottic view (25.4% versus 11.5%, P = 0.01), increase the incidence of difficult intubation (12.3% versus 4.6%, P = 0.04), and decrease the rate of intubation on the first attempt (76.2% versus 85.4%, P = 0.02). The authors conclude the ramped position did not improve oxygenation during endotracheal intubation of critically ill adults compared with the sniffing position, and may worsen glottic view and increase the number of laryngoscopy attempts.

Watch out: A single trial (Tier C), with intubations performed by fellows in intensive care units; the result does not address ramped positioning for obese patients or in the operating room, where the question and the evidence differ.

Source: Semler MW et al. A Multicenter, Randomized Trial of Ramped Position vs Sniffing Position During Endotracheal Intubation of Critically Ill Adults. Chest. 2017. PMID: 28487139. Registry ID: NCT02497729 (ClinicalTrials.gov number, as given in the record). MeSH: Adult · Aged · Critical Illness · Female · Follow-Up Studies · Humans · Hypoxia · Intensive Care Units · Intubation, Intratracheal · Laryngoscopy · Male · Middle Aged · Patient Positioning · Posture · Retrospective Studies · Treatment Outcome