Conduction system pacing versus biventricular pacing for cardiac resynchronisation: ejection fraction rose more with conduction system pacing in 1 trial and similarly in another, with more lead revisions long-term (documented N = 150)
Shelf #9500 · Heart, vessels, blood pressure & clotting
POSSIBLE (benefit) — in 2 randomised trials totalling 150 patients, conduction system pacing narrowed the QRS and raised ejection fraction at least as much as biventricular pacing: the ejection-fraction rise at 6 months was greater with His-Purkinje-optimised CRT in HOT-CRT (+12.4 versus +8.0 percentage points; P = 0.02) and not significantly different in His-Alternative (+16 versus +13 points), where His pacing thresholds were higher and long-term follow-up found more lead revisions and generator replacements with His pacing
Stamped: 2026-11-28.
Evidence published: 2021–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with symptomatic heart failure and reduced ejection fraction who meet indications for cardiac resynchronisation therapy, does conduction system pacing (His bundle pacing, with left bundle branch pacing where needed) improve ejection fraction and clinical outcomes compared with conventional biventricular pacing?
Balance of the evidence
POSSIBLE (benefit) — Composition: 2 randomised trials; documented total N = 150 (50 + 100). In His-Alternative (Vinther 2021), 50 patients with symptomatic heart failure, ejection fraction 35% or lower and left bundle branch block were randomised to His bundle pacing CRT or biventricular CRT: intention-to-treat ejection fraction at 6 months rose by 16 ± 7 percentage points with His pacing versus 13 ± 6 with biventricular pacing (not significant), with similar clinical and physical improvement in both arms, but pacing thresholds were higher with His pacing at implantation (1.8 ± 1.2 V versus 1.2 ± 0.8 V; P < 0.01) and at 6 months (2.3 ± 1.4 V versus 1.4 ± 0.5 V; P < 0.01), and 7 patients crossed over from His to left ventricular pacing at implantation. In HOT-CRT (Vijayaraman 2023), 100 patients with ejection fraction under 50% and a CRT indication were randomised to His-Purkinje conduction system pacing optimised CRT (a coronary sinus lead added if electrical resynchronisation was incomplete) or biventricular pacing: the change in ejection fraction at 6 months was greater with conduction system pacing (12.4% ± 7.3% versus 8.0% ± 10.1%; P = 0.02), complications occurred in 3 (6%) versus 10 (20%) patients (P = 0.03), and the primary safety end point was similar (98% versus 94%). Ejection fraction is an imaging measurement stated as measured; neither trial was powered for death or hospitalisation. The His-SYNC pilot's on-treatment analysis (PMID 31096064) is not carded here because that record is already carded in pack #3369. POSSIBLE: conduction system pacing achieved equal or greater measured resynchronisation and ejection-fraction improvement than biventricular pacing in two small randomised trials, at the cost of higher His pacing thresholds — long-term lead performance is the open concern.
MeSH: Bundle-Branch Block · Cardiac Resynchronization Therapy · Humans · Stroke Volume · Ventricular Function, Left · Bundle of His
Cards (3)
Card 1 — His pacing versus biventricular pacing in LBBB: similar ejection-fraction rise, higher pacing thresholds (Vinther 2021, JACC: Clinical Electrophysiology — His-Alternative randomised trial, N = 50)
Study: Randomised controlled trial
Population: 50 patients with symptomatic heart failure, left ventricular ejection fraction 35% or lower and left bundle branch block, randomised 1:1 to cardiac resynchronisation by His bundle pacing (His-CRT) or by conventional biventricular pacing (BiV-CRT), followed for 6 months. At implantation, 7 patients crossed over from His pacing to left ventricular pacing in the His-CRT group and 1 patient crossed over the other way; His-corrective pacing was achieved in 72% of the His-CRT group.
Summary: His pacing versus biventricular pacing in LBBB: similar ejection-fraction rise, higher pacing thresholds (Vinther 2021, JACC: Clinical Electrophysiology — His-Alternative randomised trial, N = 50)
Result: Intention-to-treat left ventricular ejection fraction increased by 16 ± 7 percentage points in the His-CRT group compared with 13 ± 6 in the BiV-CRT group (not significant), and improvements in clinical and physical parameters in both arms did not differ significantly. Per protocol, ejection fraction at 6 months was higher with His-CRT (48 ± 8% versus 42 ± 8%; P < 0.05) and end-systolic volume lower (65 ± 22 mL versus 83 ± 27 mL; P < 0.05) — imaging measurements stated as measured. Pacing thresholds were higher for His-CRT at implantation (1.8 ± 1.2 V versus 1.2 ± 0.8 V; P < 0.01) and at 6 months (2.3 ± 1.4 V versus 1.4 ± 0.5 V; P < 0.01). A 5-year follow-up report of this same trial (PMID 41973899) found more lead revisions (37% versus 3%) and generator replacements (47% versus 10%) in the His-CRT group, with no significant difference in death or heart-failure hospitalisation; it is the same 50 patients and is not counted again in this shelf's total.
Watch out: Crossover at implantation was one-way and frequent (7 of 25 assigned to His pacing), so the intention-to-treat comparison is diluted and the cleaner per-protocol comparison is no longer a randomised one.
Source: Vinther M et al. A Randomized Trial of His Pacing Versus Biventricular Pacing in Symptomatic HF Patients With Left Bundle Branch Block (His-Alternative). JACC. Clinical electrophysiology. 2021. PMID: 34167929. Registry ID: none in the record. MeSH: Bundle-Branch Block/therapy; Cardiac Resynchronization Therapy; Humans; Stroke Volume; Treatment Outcome; Ventricular Function, Left
Card 2 — His-Purkinje-optimised CRT raised ejection fraction more than biventricular pacing at 6 months (Vijayaraman 2023, JACC: Clinical Electrophysiology — HOT-CRT randomised trial, N = 100)
Study: Randomised controlled trial
Population: 100 patients (31% women, mean age 70 years, mean ejection fraction 31.5%) with heart failure, reduced ejection fraction (under 50%) and an indication for cardiac resynchronisation therapy, randomised to His-Purkinje conduction system pacing optimised CRT (HOT-CRT; His bundle pacing or left bundle branch pacing, with a coronary sinus lead added if electrical resynchronisation was incomplete) or biventricular pacing. HOT-CRT was successful in 48 of 50 patients (96%) and biventricular CRT in 41 of 50 (82%) (P = 0.03).
Summary: His-Purkinje-optimised CRT raised ejection fraction more than biventricular pacing at 6 months (Vijayaraman 2023, JACC: Clinical Electrophysiology — HOT-CRT randomised trial, N = 100)
Result: QRS duration decreased from 164 ± 26 ms to 137 ± 20 ms with HOT-CRT and from 166 ± 28 ms to 141 ± 19 ms with biventricular pacing. The primary outcome, change in left ventricular ejection fraction at 6 months, was greater in HOT-CRT than in biventricular pacing (12.4% ± 7.3% versus 8.0% ± 10.1%; P = 0.02) — an imaging measurement stated as measured. The primary safety end point (freedom from major complications) was similar (98% versus 94%; P = 0.62). Echocardiographic response (ejection fraction improvement over 5 points) occurred in 80% versus 61% (P = 0.06), and complications occurred in 3 patients (6%) in HOT-CRT versus 10 (20%) in biventricular pacing (P = 0.03). Procedure duration was similar (119 ± 42 versus 114 ± 36 minutes).
Watch out: HOT-CRT is a hybrid strategy — a coronary sinus lead was added when conduction pacing alone did not resynchronise — so the comparison is between strategies, not between a His lead and a left ventricular lead in isolation; 6 months is short for lead performance.
Source: Vijayaraman P et al. His-Purkinje Conduction System Pacing Optimized Trial of Cardiac Resynchronization Therapy vs Biventricular Pacing: HOT-CRT Clinical Trial. JACC. Clinical electrophysiology. 2023. PMID: 37715742. Registry ID: NCT04561778 (ClinicalTrials.gov, as printed in the record). MeSH: Humans; Female; Cardiac Resynchronization Therapy/adverse effects/methods; Bundle-Branch Block; Bundle of His; Stroke Volume; Prospective Studies; Ventricular Function, Left; Electrocardiography/methods
Card 3 — Synthesis: two small randomised trials favour conduction system pacing on imaging measures, with a lead-performance caveat — POSSIBLE (benefit)
Study: Synthesis
Population: Patients with symptomatic heart failure and reduced ejection fraction meeting CRT indications, including left bundle branch block, as enrolled in the two carded trials.
Summary: Synthesis: two small randomised trials favour conduction system pacing on imaging measures, with a lead-performance caveat — POSSIBLE (benefit)
Result: Both trials achieved QRS narrowing and ejection-fraction improvement at least equal to biventricular pacing, and one (HOT-CRT) found a significantly greater ejection-fraction rise. Neither was powered for death or hospitalisation. The counterweight is device performance: higher His pacing thresholds in His-Alternative, and, in that trial's 5-year follow-up of the same patients, more lead revisions and generator replacements after His pacing. The His-SYNC pilot trial answers the same head-to-head question, but its only PubMed record (PMID 31096064) is already carded in pack #3369 (His-bundle and physiologic pacing versus right-ventricular pacing), so it is not carded again here; this shelf is distinct from #3369, whose question is physiologic pacing versus right-ventricular pacing in patients who need ventricular pacing.
Watch out: Six-month imaging outcomes in 150 patients cannot settle a device choice whose costs and benefits play out over years of lead performance and battery life.
Source: Synthesis of the two carded records in this shelf (PMIDs 34167929 and 37715742). No additional publications are carded.