SourceMed · Shelf #955 in the ask interface
Closed-loop insulin delivery for type 2 diabetes: hospital and home
Shelf #955 · Diabetes, glucose & metabolism
POSSIBLE
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2018–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In type 2 diabetes, does fully closed-loop insulin delivery keep glucose in range better than conventional insulin therapy — in hospital inpatients on general wards, and in outpatients at home?
Balance of the evidence
POSSIBLE: In hospital, one open-label randomised trial (Bally 2018, 136 inpatients on general wards) found fully closed-loop delivery put sensor glucose in range 65.8% of the time versus 41.5% on conventional subcutaneous therapy, with no difference in hypoglycaemia exposure. Out of hospital, one small single-centre crossover trial (Daly 2023, 28 randomised adults) found the same direction, much larger: 66.3% versus 32.3% time in range over 8-week periods. Each setting rests on a single trial — the inpatient one moderately sized, the outpatient one small — so the shelf is POSSIBLE in both settings, with the direction consistent.
MeSH: Blood Glucose/analysis · Diabetes Mellitus, Type 2/blood,drug therapy · Hospitalization · Hypoglycemic Agents/administration & dosage · Infusions, Subcutaneous · Insulin/administration & dosage · Insulin Infusion Systems/adverse effects
Cards (3)
Card 1 — Bally 2018: on general wards, closed-loop delivery kept glucose in range 65.8% of the time versus 41.5% on conventional insulin therapy
Study: Randomised, open-label trial on general wards in two tertiary hospitals
Population: 136 adults with type 2 diabetes requiring subcutaneous insulin therapy on general wards in two tertiary hospitals (UK and Switzerland), assigned to closed-loop insulin delivery (70) or conventional subcutaneous insulin therapy (66), for up to 15 days or until discharge; the abstract does not state mean age or the sex mix.
Summary: Closed-loop delivery on general wards (2018): kept glucose in range 65.8% of the time versus 41.5% on conventional insulin therapy.
Result: The mean percentage of time sensor glucose was in the target range of 100 to 180 mg/dL was 65.8% (SD 16.8) in the closed-loop group and 41.5% (SD 16.9) in the control group — a difference of 24.3 percentage points (95% CI, 18.6 to 30.0; P<0.001). Time above range was 23.6% versus 49.5% (difference 25.9 points [19.2 to 32.7]; P<0.001), and mean glucose was 154 vs 188 mg/dL (P<0.001). There was no significant difference in the duration of hypoglycaemia (sensor glucose <54 mg/dL; P=0.80) or in insulin delivered (median 44.4 U vs 40.2 U; P=0.50). No episode of severe hypoglycaemia or clinically significant hyperglycaemia with ketonaemia occurred in either group.
Watch out: A glucose-control (surrogate) endpoint over at most 15 days in two tertiary centres with research support: the trial does not show fewer infections, shorter stays, or any clinical outcome benefit, and ward staffing in the trial is not ward staffing in general.
Source: Bally L et al. Closed-Loop Insulin Delivery for Glycemic Control in Noncritical Care. N Engl J Med. 2018;379(6):547-556. PMID: 29940126. Registry ID: ClinicalTrials.gov NCT01774565, from the record's databank fields.
Card 2 — Daly 2023: at home, fully closed-loop delivery doubled time in range versus standard insulin therapy in a small crossover trial (66.3% vs 32.3%)
Study: Open-label, single-centre, randomised crossover trial
Population: 26 adults with type 2 diabetes analysed (30 recruited, 28 randomised) — 7 women and 19 men among those described; mean age 59 years (SD 11); baseline HbA1c 9.0% (SD 1.4%) — each undergoing two 8-week periods of fully closed-loop delivery (CamAPS HX, no meal bolusing) and standard insulin therapy with a masked sensor, in random order.
Summary: Closed-loop at home (2023): doubled time in range versus standard insulin therapy in a small crossover trial ( 66.3% vs 32.3% ).
Result: Time in the target range (3.9–10.0 mmol/L (≈70–180 mg/dL)) was 66.3% (SD 14.9) with closed-loop versus 32.3% (SD 24.7) with control (mean difference 35.3 percentage points [95% CI, 28.0–42.6]; P < 0.001). Mean glucose was 9.2 (SD 1.2) vs 12.6 (SD 3.0) mmol/L (≈166 vs 227 mg/dL) (difference −3.6 mmol/L (≈-65 mg/dL) [−4.6 to −2.5]; P < 0.001), and HbA1c was lower after closed-loop (7.3% [SD 0.8]) than after control (8.7% [SD 1.2]; difference −1.4% [−1.0 to −1.8]; P < 0.001). Time below 3.9 mmol/L (≈70 mg/dL) was similar (median 0.44% vs 0.08%; P = 0.43). No severe hypoglycaemia occurred in either period; one treatment-related serious adverse event occurred during closed-loop.
Watch out: Pinned at build as the topic file's 'outpatient confirmatory trial': it confirms direction, but with 28 randomised participants at one expert centre and a poorly controlled study population (baseline HbA1c 9.0%), its effect size should not be quoted as the expected real-world gain.
Source: Daly AB et al. Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial. Nat Med. 2023;29(1):203-208. PMID: 36631592. Registry ID: ClinicalTrials.gov NCT04701424, from the record's databank fields.
Card 3 — Synthesis: closed-loop beats conventional insulin delivery on time in range in both settings — POSSIBLE, one trial per setting
Study: Synthesis
Population: Synthesis of the cards above: Bally 2018 (136 hospital inpatients) and Daly 2023 (28 randomised outpatients, crossover).
Summary: Closed-loop beats conventional insulin delivery on time in range in both settings — POSSIBLE, one trial per setting.
Result: Both randomised comparisons favour fully closed-loop delivery by wide margins on time in range (+24.3 points inpatient, +35.3 points outpatient) with no increase in hypoglycaemia time in either. What the shelf does not hold: a second trial in either setting, or any clinical-outcome endpoint. Hybrid closed-loop in type 1 diabetes lives on Shelf #561 and inpatient basal-bolus strategy on Shelf #355; neither is re-carded here.
Watch out: Time in range is a surrogate. Anyone quoting this shelf for length of stay, infection, or mortality is quoting past the evidence.
Source: Synthesis of Bally L et al. N Engl J Med. 2018;379(6):547-556. PMID: 29940126; Daly AB et al. Nat Med. 2023;29(1):203-208. PMID: 36631592. Registry IDs as on the individual cards.