SourceMed · Shelf #9590 in the ask interface

Rapid serological tests and the Widal test for typhoid (enteric) fever (3 syntheses: Cochrane 37 studies, 5,080 participants; TUBEX meta-analysis of 10 studies; paediatric network analysis of 196 studies): rapid tests pool at sensitivity 69–84% / specificity 79–90% by brand, the Widal test ranges 32–95% / 4–98%, and adding a Widal slide test to another test did not substantially improve performance

Shelf #9590 · Liver & gut

MEASUREMENT ACCURACY — NOT ESTABLISHED for any serological test as a replacement for culture: rapid-test pooled sensitivity (labelled in words at first occurrence) runs 69–84% with specificity 79–90% depending on brand, and the Widal test's reported sensitivity ranges from 32% to 95% with specificity from 4% to 98% across studies — a spread so wide that a Widal result, positive or negative, cannot carry a diagnosis on its own

Stamped: 2026-11-28.

Evidence published: 2017–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In people with suspected typhoid or paratyphoid (enteric) fever in endemic areas, how accurately do rapid serological tests (TUBEX, Typhidot, Test-It Typhoid — named as published) and the Widal agglutination test detect Salmonella Typhi or Paratyphi infection against blood or bone-marrow culture?

Balance of the evidence

MEASUREMENT ACCURACY — NOT ESTABLISHED as a replacement for culture — Composition: 3 overlapping syntheses (Cochrane: 37 studies, 5,080 participants; TUBEX-focused meta-analysis: 10 accuracy studies within a 16-study review; paediatric Bayesian network analysis: 196 studies, 57 in children — counted as syntheses, never as independent cohorts). Wijedoru 2017 (Cochrane): meta-analysis gave TUBEX sensitivity 78% (95% CI 71–85%) and specificity 87% (82–91%); Test-It Typhoid and prototypes sensitivity 69% (59–78%) and specificity 90% (78–93%); Typhidot across all forms sensitivity 84% (73–91%) and specificity 79% (70–87%); only 3 studies used the strictest (culture plus bone-marrow) reference and only 11 recruited unselected febrile patients. Bundalian 2019: across studies, the Widal test's sensitivity ranged 32–95% and specificity 4–98%, against TUBEX ranges of 55–100% / 58–100% and Typhidot 54–67% / 54–95%, with pooled estimates favouring TUBEX. Arora 2019 (children): IgM-based formats outperformed IgG-based ones for ELISA and Typhidot; the reverse passive haemagglutination assay was the most sensitive test examined (99%), and adding a Widal slide test to other diagnostics did not substantially improve performance. MEASUREMENT ACCURACY — NOT ESTABLISHED: in endemic settings these serologies can support a clinical suspicion, but their pooled and ranged performance — above all the Widal test's — is too weak and too variable to confirm or exclude enteric fever without culture. Sensitivity and specificity are labelled in words at first occurrence in this balance, per the labelling rule.

MeSH: Typhoid Fever · Serologic Tests · Sensitivity and Specificity · Salmonella typhi · Reagent Kits, Diagnostic

Cards (4)

Card 1 — Cochrane: TUBEX sensitivity 78% / specificity 87%, Test-It 69% / 90%, Typhidot 84% / 79% against culture in 37 studies and 5,080 participants (Wijedoru 2017)

Study: Systematic review and meta-analysis (Cochrane diagnostic accuracy; 37 studies, 5,080 participants)

Population: A Cochrane diagnostic-accuracy review of 37 studies (5,080 participants with fever or suspected enteric fever in endemic areas; prevalence 1–75%, median 24%) evaluating 16 rapid diagnostic tests against Grade 1 reference (blood plus bone-marrow culture; 3 studies) or Grade 2 (blood culture with PCR, or blood culture alone). Sensitivity and specificity are labelled in words here at first occurrence on this shelf, per the shelf's labelling rule.

Summary: Cochrane: TUBEX sensitivity 78% / specificity 87%, Test-It 69% / 90%, Typhidot 84% / 79% against culture in 37 studies and 5,080 participants (Wijedoru 2017)

Result: Meta-analyses showed average sensitivity 78% (95% CI 71% to 85%) and specificity 87% (82% to 91%) for TUBEX (14 studies); sensitivity 69% (59% to 78%) and specificity 90% (78% to 93%) for all Test-It Typhoid and prototype (KIT) tests (9 studies); and across all Typhidot forms (22 studies) sensitivity 84% (73% to 91%) and specificity 79% (70% to 87%). All tests were designed to detect S. Typhi only, most studies were from Asia, and only 11 recruited unselected febrile patients.

Watch out: Reference standards were mostly blood culture alone (Grade 2), which itself misses cases — accuracy against an imperfect reference is printed as the review reports it. Paratyphi A detection was barely studied; the pooled figures are Typhi figures.

Source: Wijedoru L, Mallett S, Parry CM. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever. The Cochrane database of systematic reviews. 2017. PMID: 28545155. Registry ID: not stated in the record. MeSH: Adult · Child · False Negative Reactions · False Positive Reactions · Humans · Immunoassay · Paratyphoid Fever · Polymerase Chain Reaction · Reagent Kits, Diagnostic · Reference Standards · Sensitivity and Specificity · Typhoid Fever

Card 2 — The Widal test's reported sensitivity spans 32–95% and specificity 4–98% across studies — the widest spread of any test in the comparison (Bundalian 2019, 10-study meta-analysis)

Study: Systematic review and meta-analysis (serological test accuracy; 10 studies pooled)

Population: A review and meta-analysis of serological typhoid diagnostics: 16 studies in the qualitative analysis and 10 in the pooled meta-analysis, comparing TUBEX TF against the Widal test and Typhidot as the commonly used alternatives.

Summary: The Widal test's reported sensitivity spans 32–95% and specificity 4–98% across studies — the widest spread of any test in the comparison (Bundalian 2019, 10-study meta-analysis)

Result: Across studies, sensitivity/specificity ranges were 55–100% / 58–100% for TUBEX TF, 54–67% / 54–95% for Typhidot, and 32–95% / 4–98% for the Widal test. The pooled meta-analysis estimates favoured TUBEX TF for differentiating typhoid fever from other febrile illness, and the authors concluded TUBEX was the more advantageous serological test while calling for further validation studies.

Watch out: The Widal figures are ranges across heterogeneous studies (different cut-offs, populations and background immunity), not a pooled estimate — that heterogeneity is itself the finding, and the card presents it as a range rather than inventing a pool the authors did not give for Widal.

Source: Bundalian R, Valenzuela M, Tiongco RE et al. Achieving accurate laboratory diagnosis of typhoid fever: a review and meta-analysis of TUBEX® TF clinical performance. Pathogens and global health. 2019. PMID: 31778097. Registry ID: not stated in the record. MeSH: Clinical Laboratory Techniques · Evaluation Studies as Topic · Humans · Reagent Kits, Diagnostic · Salmonella typhi · Sensitivity and Specificity · Serologic Tests · Typhoid Fever

Card 3 — In children, adding a Widal slide test to another diagnostic did not substantially improve performance; the most sensitive test was reverse passive haemagglutination at 99% (Arora 2019, network analysis of 196 studies)

Study: Systematic review with Bayesian latent-class network meta-analysis (196 studies; paediatric focus)

Population: A systematic review and Bayesian latent-class network meta-analysis of typhoid diagnostic comparisons against blood culture (510 comparisons from 196 studies; 57 studies in the paediatric population aged 15 or under), modelling bone-marrow culture performance as informative priors because no perfect reference exists.

Summary: In children, adding a Widal slide test to another diagnostic did not substantially improve performance; the most sensitive test was reverse passive haemagglutination at 99% (Arora 2019, network analysis of 196 studies)

Result: IgM-based tests outperformed their IgG-based counterparts for ELISA and Typhidot. The lateral-flow IgG test achieved sensitivity 92% and specificity 94%; the reverse passive haemagglutination assay was the most sensitive test investigated for the South Asian paediatric population (99% sensitivity, 98–100% across scenario analyses). Adding a Widal slide test to other diagnostics did not substantially improve diagnostic performance beyond the single test alone; the best combination was a lateral-flow IgG rapid test with the typhoid/paratyphoid (TPT) assay.

Watch out: Latent-class estimates depend on the modelled priors for culture performance, and the informed data are concentrated in South Asia — the authors state the evidence base in other endemic regions needs expanding. Paediatric population; adult performance may differ.

Source: Arora P, Thorlund K, Brenner DR et al. Comparative accuracy of typhoid diagnostic tools: A Bayesian latent-class network analysis. PLoS neglected tropical diseases. 2019. PMID: 31067228. Registry ID: not stated in the record. MeSH: Adolescent · Child · Child, Preschool · Female · Humans · Male · Young Adult · Antibodies, Bacterial · Bayes Theorem · Diagnostic Tests, Routine · Reagent Kits, Diagnostic · Salmonella typhi · Sensitivity and Specificity · Typhoid Fever

Card 4 — Synthesis: no serological test — rapid kit or Widal — reaches the accuracy needed to replace culture for enteric fever

Study: Synthesis of the carded syntheses (3 overlapping systematic reviews)

Population: Synthesis of the three carded syntheses (37 + 10 + 196 studies with overlapping primary sets — counted as syntheses, never as independent cohorts).

Summary: Synthesis: no serological test — rapid kit or Widal — reaches the accuracy needed to replace culture for enteric fever

Result: The best rapid tests pool at sensitivity in the high 70s to mid 80s with specificity in the 80s — enough to shift probability in a febrile patient in an endemic area, not enough to confirm or exclude typhoid. The century-old Widal test is worse and wildly inconsistent (sensitivity 32–95%, specificity 4–98%), and in the paediatric network analysis it added nothing to other tests. Culture remains the reference these tests are judged against, not a test they can retire.

Watch out: Three syntheses over overlapping literatures — the convergence of their conclusions (moderate rapid-test accuracy, unusable Widal variability) is the signal; their study counts must not be summed.

Source: Synthesis of the carded records above (PMIDs 28545155, 31778097, 31067228). Registry ID: not stated in the records. MeSH: Typhoid Fever · Serologic Tests · Sensitivity and Specificity · Salmonella typhi