SourceMed · Shelf #9639 in the ask interface

Exhaled carbon monoxide for verifying smoking abstinence (3 studies, documented N = 1,201): the traditional 8–10 ppm cutoff misclassified 14.0–20.6% of cotinine-confirmed smokers as abstinent, a 3 ppm cutoff classified 97.1% correctly in trial participants, 2–3 ppm was optimal across the postpartum year — yet 10–11 ppm was optimal in asthma and COPD outpatients, whose breath CO runs high without smoking

Shelf #9639 · Lungs, breathing & sleep

MEASUREMENT ACCURACY — NOT ESTABLISHED at any single universal cutoff: against cotinine, a 3 ppm cutoff classified 97.1% of cessation-trial participants correctly while the traditional 8 ppm and 10 ppm cutoffs misclassified 14.0% and 20.6% of smokers as abstinent; postpartum data also favour 2–3 ppm — but in asthma and COPD outpatients the optimal cutoffs were 10 ppm (sensitivity 85.0% / specificity 85.8%, labelled in words at first occurrence here) and 11 ppm (sensitivity 73.1% / specificity 84.7%), because airway disease itself raises breath CO. The right cutoff is a population property, not a device constant

Stamped: 2026-11-28.

Evidence published: 2003–2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does exhaled (expired-air) carbon monoxide distinguish smokers from abstainers against cotinine — what sensitivity and specificity (labelled in words) does it achieve at the traditional 8–10 ppm cutoffs and at lower cutoffs, and how does the optimal cutoff move between trial participants, postpartum women, and patients with asthma or COPD?

Balance of the evidence

MEASUREMENT ACCURACY — NOT ESTABLISHED at a universal cutoff — Composition: 3 primary accuracy studies, documented N = 1,201 (662 + 208 + 331), each against a cotinine reference. Cropsey 2014 (662 cessation-trial participants, cotinine reference): a 3 ppm cutoff gave 97.1% correct classification in both racial and gender groups, while 8 ppm misclassified 14.0% and 10 ppm misclassified 20.6% of smokers as abstainers. Emery 2016 (208 postpartum women, salivary cotinine, assessments at 12, 24 and 52 weeks): cutoffs of 2 and 3 ppm had the highest overall efficiency and combined sensitivity and specificity (labelled in words) across the postpartum year, consistently in Black and White women. Sato 2003 (331 asthma/COPD outpatients, serum cotinine): optimal cutoffs were 10 ppm in asthma (sensitivity 85.0%, specificity 85.8%) and 11 ppm in COPD (sensitivity 73.1%, specificity 84.7%) — the opposite direction from the trial populations, because never- and former-smokers with airway disease already blow 6–8 ppm. Sensitivity and specificity are labelled in words at first occurrence in this balance, per the labelling rule. No live shelf or pack on disk asks the exhaled-CO verification question. MEASUREMENT ACCURACY — NOT ESTABLISHED at any single universal cutoff: 3 ppm verifies abstinence in trial and postpartum populations; in asthma and COPD the same reading cannot separate smoking from the disease's own CO.

MeSH: Adult · Biomarkers · Breath Tests · Carbon Monoxide · Cotinine · Female · Humans · Male · Middle Aged · Reference Standards · Smoking · Smoking Cessation

Cards (4)

Card 1 — At 8–10 ppm, one in five smokers can pass as abstinent; at 3 ppm, classification was 97.1% correct (Cropsey 2014, n = 662)

Study: Primary accuracy study (exhaled CO vs cotinine, ROC analysis; n = 662)

Population: Six hundred sixty-two participants in a smoking-cessation clinical trial, with exhaled carbon monoxide compared against cotinine confirmation of abstinence by receiver-operating-characteristic analysis, examined across race and gender. Sensitivity and specificity are the accuracy measures for this shelf's question and are labelled in words where pairs are printed.

Summary: At 8–10 ppm, one in five smokers can pass as abstinent; at 3 ppm, classification was 97.1% correct (Cropsey 2014, n = 662)

Result: A carbon-monoxide cutoff of 3 ppm most accurately distinguished smokers from nonsmokers, with 97.1% correct classification, and the same cutoff was accurate for both racial and gender groups. The standard cutoffs performed poorly in the direction that matters for trials: 8 ppm misclassified 14.0% of smokers as abstinent and 10 ppm misclassified 20.6%. The authors recommend a cutoff in the range of 3–4 ppm when complete abstinence is the goal.

Watch out: Trial participants motivated to quit, tested at trial visits; the misclassification percentages are this sample's, and recent-smoking timing (CO's short half-life) is the mechanism behind them — a smoker who abstained for hours before the visit blows low at any cutoff.

Source: Cropsey KL et al. How low should you go? Determining the optimal cutoff for exhaled carbon monoxide to confirm smoking abstinence when using cotinine as reference.. Nicotine & tobacco research : official journal of the Society for Research on Nicotine and Tobacco. 2014. PMID: 24891552. Registry ID: not stated in the record. MeSH: Adult · Biomarkers · Breath Tests · Carbon Monoxide · Cotinine · Female · Humans · Male · Middle Aged · Reference Standards · Smoking · Smoking Cessation

Card 2 — Postpartum, the optimum stays at 2–3 ppm all year — far below the standard 8 ppm criterion (Emery 2016, n = 208)

Study: Primary accuracy study (expired-air CO vs salivary cotinine; n = 208 women, 3 time points)

Population: Two hundred eight women who had quit smoking during pregnancy, enrolled in a postpartum relapse-prevention study, with smoking status assessed at 12, 24 and 52 weeks postpartum by both expired-air carbon monoxide and salivary cotinine as the reference criterion; receiver-operating-characteristic analyses at each time point, examined separately in Black and White women.

Summary: Postpartum, the optimum stays at 2–3 ppm all year — far below the standard 8 ppm criterion (Emery 2016, n = 208)

Result: Carbon monoxide provided moderately high diagnostic accuracy against cotinine across the postpartum year. Cutoffs of 2 and 3 ppm had the highest overall efficiency and the highest combined sensitivity and specificity (labelled in words at first occurrence on this shelf) at every assessment, and results were consistent for Black and White women. The authors conclude the optimal criterion is stable across the postpartum year and far below the standard clinical criterion of 8 ppm.

Watch out: The record reports the optimal cutoffs and their ranking without printing the numeric sensitivity and specificity at 2–3 ppm, so none is carded — the card establishes where the optimum sits, and the numeric pairs on this shelf come from the Sato card.

Source: Emery RL et al. Optimal Carbon Monoxide Criteria to Confirm Smoking Status Among Postpartum Women.. Nicotine & tobacco research : official journal of the Society for Research on Nicotine and Tobacco. 2016. PMID: 26386471. Registry ID: not stated in the record. MeSH: Adult · Breath Tests · Carbon Monoxide · Cotinine · Female · Humans · Postpartum Period · Pregnancy · ROC Curve · Saliva · Smoking · Young Adult

Card 3 — In asthma and COPD outpatients the optimum flips to 10–11 ppm — sensitivity 85.0% / specificity 85.8% in asthma, 73.1% / 84.7% in COPD (Sato 2003, n = 331)

Study: Primary accuracy study (breath CO vs serum cotinine; n = 331 outpatients)

Population: Three hundred thirty-one consecutive outpatients (161 with asthma, 170 with COPD) at a university hospital, examined cross-sectionally by self-reported smoking status, breath carbon monoxide and serum cotinine as the verification of actual smoking status. Sensitivity and specificity are labelled in words at first occurrence on this card.

Summary: In asthma and COPD outpatients the optimum flips to 10–11 ppm — sensitivity 85.0% / specificity 85.8% in asthma, 73.1% / 84.7% in COPD (Sato 2003, n = 331)

Result: Mean breath CO in asthma was 6.1 ± 2.4 ppm in never-smokers, 7.7 ± 3.2 in former smokers and 19.9 ± 17.3 in current smokers; in COPD, 7.7 ± 4.3 in former smokers and 13.5 ± 6.5 in current smokers. The optimal cutoff to discriminate actual smokers from nonsmokers was 10 ppm in asthma, giving sensitivity 85.0% and specificity 85.8%, and 11 ppm in COPD, giving sensitivity 73.1% and specificity 84.7%. The authors note breath CO is potentially influenced by underlying airway inflammation.

Watch out: A single Japanese outpatient sample from 2003; the elevated nonsmoker baseline is the finding — it is why the trial-population cutoff of 3 ppm would fail in this clinic population, and why neither cutoff travels.

Source: Sato S et al. Optimal cutoff level of breath carbon monoxide for assessing smoking status in patients with asthma and COPD.. Chest. 2003. PMID: 14605044. Registry ID: not stated in the record. MeSH: Adolescent · Adult · Aged · Asthma · Breath Tests · Carbon Monoxide · Cotinine · Cross-Sectional Studies · Female · Humans · Male · Middle Aged · Pulmonary Disease, Chronic Obstructive · Sensitivity and Specificity · Smoking · Smoking Cessation

Card 4 — Synthesis — the cutoff is a population property: 3 ppm where lungs are healthy, 10–11 ppm where the disease itself exhales CO

Study: Synthesis

Population: Synthesis of the reports carded on this shelf; no additional source.

Summary: Synthesis — the cutoff is a population property: 3 ppm where lungs are healthy, 10–11 ppm where the disease itself exhales CO

Result: Read together, the three studies do not disagree — they triangulate. In cessation-trial and postpartum populations, low cutoffs (2–3 ppm) verify abstinence accurately and the inherited 8–10 ppm standard lets 14–21% of continuing smokers pass as quitters. In asthma and COPD outpatients, nonsmokers already exhale 6–8 ppm, so the discriminating cutoff rises to 10–11 ppm and accuracy falls (COPD sensitivity only 73.1%). Any protocol that prints one CO number for every population has built one of these two errors in.

Watch out: All references are cotinine, which itself has a detection window of days, not the hours of CO; secondhand-smoke exposure and time since last cigarette move individual readings in every study carded.

Source: Synthesis of the reports carded above; no additional source.