SourceMed · Shelf #9641 in the ask interface
WHO Haemoglobin Colour Scale for anaemia where there is no laboratory (3 overlapping syntheses and field evaluations): pooled sensitivity 80% / specificity 80% for anaemia — better than clinical assessment's sensitivity of 52% — but sensitivity for severe anaemia was only 57% pooled and 24–63% in the Kenyan field evaluation, at specificity of 97–100%
Shelf #9641 · Heart, vessels, blood pressure & clotting
MEASUREMENT ACCURACY — established as better than clinical assessment for detecting anaemia, NOT ESTABLISHED for ruling out severe anaemia: pooled sensitivity 80% and specificity 80% (labelled in words at first occurrence here) for anaemia against clinical assessment's sensitivity of 52%, but pooled sensitivity for severe anaemia was only 57% (specificity 99.6%), and in the largest field evaluation severe-anaemia sensitivity ran 24–63% across groups — a negative colour-scale reading cannot exclude the severe anaemia that matters most
Stamped: 2026-11-28.
Evidence published: 2005–2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does the WHO Haemoglobin Colour Scale — a blood-drop colour comparison card — diagnose anaemia and severe anaemia against laboratory or HemoCue haemoglobin in primary-care and community settings without a laboratory, and how does it compare with clinical assessment alone?
Balance of the evidence
MEASUREMENT ACCURACY — established as better than clinical assessment for anaemia detection, NOT ESTABLISHED for ruling out severe anaemia — Composition: 2 systematic reviews with overlapping study sets (14 studies each, counted as syntheses) plus 1 large field evaluation (1,890 participants). Marn 2016 (14 studies, primary-care conditions): pooled sensitivity 80% (95% CI 68–88%) and specificity 80% (59–91%) for anaemia, vs clinical assessment sensitivity 52% (36–67%) and specificity 75% (56–88%); for severe anaemia, sensitivity 57% (36–76%) for the scale vs 45% (12–83%) clinically, specificity 99.6% vs 92%. Critchley 2005 (14 studies, mostly sub-Saharan Africa): sensitivity for anaemia 75–97% and specificity 41–98% across studies, higher in laboratory-based than real-life settings. Lindblade 2006 (western Kenya; 457 sick children, 336 immunisation-clinic children, 454 community children, 643 pregnant women; HemoCue reference): sensitivity for anaemia 60–79% and specificity 59–94% across groups; for severe anaemia, sensitivity 24–63% and specificity 97–100%. Sensitivity and specificity are labelled in words at first occurrence in this balance, per the labelling rule. No live shelf or pack on disk asks the colour-scale question (live #8438 covers transcutaneous bilirubinometry, a different no-laboratory measurement). MEASUREMENT ACCURACY — established as better than clinical assessment for detecting anaemia, NOT ESTABLISHED for ruling out severe anaemia.
MeSH: Anemia · Color · Colorimetry · Developing Countries · Diagnostic Tests, Routine · Hemoglobinometry · Hemoglobins · Humans · Primary Health Care · Sensitivity and Specificity
Cards (4)
Card 1 — Pooled in real-life primary care: sensitivity 80% / specificity 80% for anaemia — clinical assessment managed sensitivity of only 52% (Marn 2016)
Study: Systematic review and meta-analysis (colour-scale accuracy; 14 studies)
Population: Systematic review of 14 studies of the WHO Haemoglobin Colour Scale in primary health-care settings, compared with laboratory haemoglobin and with clinical assessment, with accuracy pooled by a bivariate model and study quality assessed by QUADAS-2. Sensitivity and specificity are labelled in words at first occurrence on this card.
Summary: Pooled in real-life primary care: sensitivity 80% / specificity 80% for anaemia — clinical assessment managed sensitivity of only 52% (Marn 2016)
Result: Pooled sensitivity of the colour scale for anaemia was 80% (95% CI 68–88%) vs 52% (36–67%) for clinical assessment (P = 0.008); specificity was similar, 80% (59–91%) vs 75% (56–88%). For severe anaemia, sensitivity was 57% (36–76%) for the scale vs 45% (12–83%) for clinical assessment, with specificity 99.6% (95–99.9%) vs 92% (62–99%). Combining clinical assessment with the scale raised sensitivity (anaemia 91%, severe anaemia 83%) at the expense of specificity (59% and 90%). Individual studies were highly heterogeneous.
Watch out: Pooled from heterogeneous real-life studies — the confidence intervals are wide (specificity 59–91%) and the severe-anaemia sensitivity of 57% is the ceiling this shelf's claim rests on, not a floor.
Source: Marn H et al. Accuracy of the WHO Haemoglobin Colour Scale for the diagnosis of anaemia in primary health care settings in low-income countries: a systematic review and meta-analysis.. The Lancet. Global health. 2016. PMID: 26905314. Registry ID: not stated in the record. MeSH: Anemia · Color · Colorimetry · Developing Countries · Diagnostic Tests, Routine · Hemoglobinometry · Hemoglobins · Humans · Primary Health Care · Sensitivity and Specificity
Card 2 — Earlier review, same 14-study territory: sensitivity 75–97% in most studies, specificity 41–98%, and laboratory settings flattered the scale (Critchley 2005)
Study: Systematic review (colour-scale accuracy; 14 studies, overlapping the 2016 pool)
Population: Systematic review of 14 studies comparing the Haemoglobin Colour Scale against a reference standard, mostly from sub-Saharan Africa, including 5 studies that also compared it with clinical diagnosis.
Summary: Earlier review, same 14-study territory: sensitivity 75–97% in most studies, specificity 41–98%, and laboratory settings flattered the scale (Critchley 2005)
Result: Sensitivity for detecting anaemia was high in most studies (75–97%) while specificity was generally lower and wider-ranging (41–98%). Sensitivity and specificity were both higher in laboratory-based studies than in pragmatic real-life studies, and study setting appeared to explain some of the heterogeneity. In four of five head-to-head studies the scale's sensitivity exceeded clinical diagnosis, while clinical diagnosis often had the higher specificity. The authors conclude the scale may improve anaemia diagnosis where there is no laboratory, with its real-life performance unsettled.
Watch out: Ranges, not pools — this earlier review did not meta-analyse, and its study set overlaps the 2016 review's; the two cards are one evidence base read twice, and this shelf counts them as overlapping syntheses.
Source: Critchley J et al. Haemoglobin colour scale for anaemia diagnosis where there is no laboratory: a systematic review.. International journal of epidemiology. 2005. PMID: 16199438. Registry ID: not stated in the record. MeSH: Anemia · Color · Developing Countries · Hemoglobinometry · Humans · Reproducibility of Results · Sensitivity and Specificity
Card 3 — Field evaluation in 1,890 Kenyan children and pregnant women: anaemia sensitivity 60–79%, but severe-anaemia sensitivity only 24–63% (Lindblade 2006)
Study: Primary field accuracy study (colour scale vs HemoCue; n = 1,890 participants)
Population: Field evaluation by primary-care nurses and community health workers in western Kenya: 457 sick children, 336 immunisation-clinic children and 454 community children aged 2 months to 2 years, plus 643 pregnant women; finger-prick blood read on the colour scale against a HemoCue portable haemoglobinometer as reference. Anaemia prevalence (haemoglobin below 11 g/dL) was 87%, 79%, 74% and 52% across the four groups; severe anaemia (below 7 g/dL) prevalence was 24%, 11%, 10% and 2%.
Summary: Field evaluation in 1,890 Kenyan children and pregnant women: anaemia sensitivity 60–79%, but severe-anaemia sensitivity only 24–63% (Lindblade 2006)
Result: Sensitivity of the scale for anaemia ranged from 60% to 79% across the groups and specificity from 59% to 94%. For severe anaemia, sensitivity ranged from only 24% to 63% while specificity was 97–100%. Despite the misses, using the scale would have raised the proportion of sick anaemic children diagnosed and treated at peripheral facilities from 3% to 65%.
Watch out: The reference is a HemoCue haemoglobinometer, not a laboratory analyser; group-specific pairs are reported as ranges in the record, so no single group's pair is singled out on this card.
Source: Lindblade KA et al. Evaluation of the WHO Haemoglobin Colour Scale for diagnosis of anaemia in children and pregnant women as used by primary health care nurses and community health workers in western Kenya.. Tropical medicine & international health : TM & IH. 2006. PMID: 17054747. Registry ID: not stated in the record. MeSH: Adolescent · Adult · Anemia · Child, Preschool · Color · Community Health Services · Diagnostic Tests, Routine · Female · Hemoglobins · Humans · Infant · Kenya · Male · Nursing Care · Pallor · Population Surveillance · Predictive Value of Tests · Pregnancy · Pregnancy Complications, Hematologic · Prevalence · Primary Health Care · Sensitivity and Specificity
Card 4 — Synthesis — use it to find anaemia where the alternative is a glance; never use a reassuring reading to exclude severe anaemia
Study: Synthesis
Population: Synthesis of the reports carded on this shelf; no additional source.
Summary: Synthesis — use it to find anaemia where the alternative is a glance; never use a reassuring reading to exclude severe anaemia
Result: The colour scale beats the clinical eye for detecting anaemia (pooled sensitivity 80% vs 52%) at comparable specificity, and in the Kenyan field study it multiplied treated anaemia sixfold-plus among sick children. Its failure mode is consistent across all three reports: severe anaemia — the presentation where a miss costs most — is detected with sensitivity of only 24–63% in the field and 57% pooled, because the scale's coarse colour steps compress at the dark, low-haemoglobin end. High severe-anaemia specificity (97–100%) means a positive severe reading is trustworthy; a negative one is not reassurance.
Watch out: Evidence is from low-income primary-care and community settings with high anaemia prevalence; accuracy at the low prevalences of well-resourced settings is not measured by anything carded here.
Source: Synthesis of the reports carded above; no additional source.