Celivarone to prevent ICD interventions or death (2 randomised trials, documented N = 639): neither trial showed a significant reduction in ventricular-arrhythmia ICD therapies or sudden death (the treatment made no difference)

Shelf #9644 · Heart, vessels, blood pressure & clotting

POSSIBLE (the treatment made no difference) — two double-blind placebo-controlled trials (486 and 153 patients) both missed their primary endpoints; the larger trial's hazard ratios straddled 1 at every dose, and its amiodarone calibrator arm performed visibly better, showing the trial design could detect an effective drug

Stamped: 2026-11-28.

Evidence published: 2011–2012.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with an implantable cardioverter-defibrillator and recent ventricular tachycardia or fibrillation, does oral celivarone, compared with placebo, reduce ICD interventions (shocks or antitachycardia pacing) or sudden death?

Balance of the evidence

POSSIBLE (the treatment made no difference) — Composition: 2 randomised double-blind placebo-controlled trials, documented N = 639 (486 + 153). In ALPHEE, the primary endpoint (ventricular tachycardia/fibrillation-triggered ICD intervention or sudden death) occurred in 61.5% on placebo and 67.0%, 58.8% and 54.9% on celivarone 50, 100 and 300 mg/day; hazard ratios versus placebo ranged from 0.860 (300 mg) to 1.199 (50 mg), none significant — while the amiodarone calibrator arm reached 45.3%, showing assay sensitivity. In the smaller 153-patient trial, ventricular episodes were fewer at 300 mg (a 46% relative reduction) but not significantly, and a favourable subgroup finding was post hoc. The stamp is held at POSSIBLE, not above it, for this null programme. Boundary: celivarone's atrial-fibrillation trials (MAIA and CORYFEE, reported together in PMID 22171925) ask different questions in a different population and are not carded here; live shelves on ICD programming (#2293) and subcutaneous versus transvenous devices (#710) do not ask about this drug. POSSIBLE (the treatment made no difference).

MeSH: Aged · Amiodarone · Anti-Arrhythmia Agents · Benzofurans · Death, Sudden, Cardiac · Defibrillators, Implantable · Dose-Response Relationship, Drug · Double-Blind Method · Drug Therapy, Combination · Female · Follow-Up Studies · Humans · Incidence · Kaplan-Meier Estimate · Male · Middle Aged · Tachycardia, Ventricular · Treatment Outcome · Ventricular Fibrillation · Arrhythmias, Cardiac · Heart Ventricles

Cards (3)

Card 1 — ALPHEE: celivarone did not prevent ICD interventions or sudden death at any dose (Kowey 2011, n = 486 randomised)

Study: Randomised double-blind placebo-controlled trial with amiodarone calibrator (n = 486 randomised)

Population: 486 patients with left ventricular ejection fraction ≤40% and at least one ICD intervention for ventricular tachycardia or fibrillation in the previous month, or ICD implantation in the previous month for documented ventricular tachycardia/fibrillation, randomised double-blind to celivarone 50, 100 or 300 mg/day, placebo, or amiodarone 200 mg/day (after a 600 mg/day 10-day load) as a calibrator. Median treatment duration was 9 months. The primary endpoint was ventricular tachycardia/fibrillation-triggered ICD interventions (shocks or antitachycardia pacing) or sudden death.

Summary: ALPHEE: celivarone did not prevent ICD interventions or sudden death at any dose (Kowey 2011, n = 486 randomised)

Result: The primary endpoint occurred in 61.5% of the placebo group; 67.0%, 58.8% and 54.9% in the celivarone 50-, 100- and 300-mg groups; and 45.3% in the amiodarone group. Hazard ratios versus placebo ranged from 0.860 for celivarone 300 mg to 1.199 for celivarone 50 mg; none of the comparisons versus placebo was statistically significant (the treatment made no difference). Celivarone had an acceptable safety profile in the record's assessment.

Watch out: The amiodarone arm was a calibrator, not a powered comparison — but its lower event proportion (45.3% versus 61.5% on placebo) shows the endpoint could move, which strengthens the null reading for celivarone rather than excusing it.

Source: Kowey PR et al. Efficacy and safety of celivarone, with amiodarone as calibrator, in patients with an implantable cardioverter-defibrillator for prevention of implantable cardioverter-defibrillator interventions or death: the ALPHEE study. Circulation. 2011. PMID: 22082672. Registry ID: ClinicalTrials.gov NCT00993382. MeSH: Aged · Amiodarone · Anti-Arrhythmia Agents · Benzofurans · Death, Sudden, Cardiac · Defibrillators, Implantable · Dose-Response Relationship, Drug · Double-Blind Method · Drug Therapy, Combination · Female · Follow-Up Studies · Humans · Incidence · Kaplan-Meier Estimate · Male · Middle Aged · Tachycardia, Ventricular · Treatment Outcome · Ventricular Fibrillation

Card 2 — Celivarone 300 mg showed a non-significant trend to fewer ventricular episodes (Gojkovic 2012, n = 153 randomised)

Study: Randomised double-blind placebo-controlled trial (n = 153 randomised)

Population: 153 eligible ICD recipients randomised double-blind to placebo or celivarone 100 or 300 mg once daily for 6 months. The primary endpoint was prevention of arrhythmia-triggered ICD therapies.

Summary: Celivarone 300 mg showed a non-significant trend to fewer ventricular episodes (Gojkovic 2012, n = 153 randomised)

Result: Fewer ventricular tachycardia and ventricular fibrillation episodes were observed in the 300-mg celivarone group than in the placebo group, with a relative risk reduction of 46%, which was not statistically significant (the treatment made no difference on the primary analysis). All-cause shocks also trended lower at 300 mg. A post hoc subgroup analysis (patients who had received ICD therapy within 1 month of randomisation) showed a significant benefit at 300 mg (P = .032). More heart failure events were reported in the celivarone groups than in the placebo group, not significantly; there was no increased risk of torsades de pointes, thyroid dysfunction or pulmonary events.

Watch out: The only significant finding is post hoc and subgroup-based; the trial's own primary analysis is null, concordant with the larger ALPHEE trial. The 46% figure is a relative reduction from a non-significant comparison — the record gives no absolute event rates for it, so none are printed.

Source: Gojkovic O et al. Celivarone in patients with an implantable cardioverter-defibrillator: adjunctive therapy for the reduction of ventricular arrhythmia-triggered implantable cardioverter-defibrillator interventions. Heart Rhythm. 2012. PMID: 21978965. Registry ID: not stated in the record. MeSH: Aged · Anti-Arrhythmia Agents · Arrhythmias, Cardiac · Benzofurans · Defibrillators, Implantable · Double-Blind Method · Female · Follow-Up Studies · Heart Ventricles · Humans · Male · Middle Aged · Tachycardia, Ventricular · Ventricular Fibrillation

Card 3 — Synthesis: a concordantly null two-trial programme — POSSIBLE (the treatment made no difference)

Study: Synthesis

Population: Documented N = 639 randomised across the two trials (486 + 153); independent populations, both ICD recipients with recent ventricular arrhythmia.

Summary: Synthesis: a concordantly null two-trial programme — POSSIBLE (the treatment made no difference)

Result: Both trials missed their primary endpoints. The larger trial tested three doses and found hazard ratios straddling 1 with no dose ordering, against an amiodarone calibrator that performed better than placebo — the pattern of a drug that does not work for this indication, tested adequately. The smaller trial's favourable signals are a non-significant trend and a post hoc subgroup.

Watch out: Celivarone was also tested in atrial fibrillation (maintenance and conversion), where it likewise showed no significant efficacy (PMID 22171925, not carded — a different question and population). Nothing in the carded records supports use for any arrhythmia indication.

Source: Synthesis of the carded records above (PMIDs 22082672, 21978965).