SourceMed · Shelf #9646 in the ask interface

Carillon coronary-sinus indirect annuloplasty for functional mitral regurgitation (2 studies, documented N = 156): the sham-controlled REDUCE FMR trial cut regurgitant volume by 7.1 mL/beat against a 3.3 mL/beat rise on sham, with left ventricular volumes also falling

Shelf #9646 · Heart, vessels, blood pressure & clotting

POSSIBLE (benefit) — one small sham-controlled randomised trial met its echocardiographic primary endpoint (regurgitant volume and ventricular volumes), supported by a 36-patient single-arm study of the modified device; no trial reports clinical-event outcomes, and the randomised effect rests on a borderline P value (0.049)

Stamped: 2026-11-28.

Evidence published: 2016–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with symptomatic functional (secondary) mitral regurgitation on optimal heart-failure therapy, does percutaneous indirect annuloplasty with the Carillon Mitral Contour System reduce regurgitant volume and left ventricular volumes compared with a sham procedure or with the patients' own baseline?

Balance of the evidence

POSSIBLE (benefit) — Composition: 1 randomised sham-controlled trial (120 patients) and 1 single-arm study of the modified device (36 patients); documented N = 156. In REDUCE FMR, regurgitant volume fell by 7.1 mL/beat on treatment and rose by 3.3 mL/beat on sham (P = 0.049), with left ventricular end-diastolic volume falling 10.4 mL against a 6.5 mL rise (P = 0.03); the device was implanted in 73 of 87 assigned patients (84%). TITAN II reported echocardiographic and functional improvements of a similar pattern with one 30-day major adverse event (a death assessed as not device-related). Boundary: live #550 and #4169 ask about edge-to-edge repair (MitraClip) for secondary mitral regurgitation, and #2252 about the PASCAL system — leaflet approximation, a different mechanism from coronary-sinus annular reduction, and none cards the Carillon device. The tested product is the Carillon Mitral Contour System (Cardiac Dimensions), named as published. POSSIBLE (benefit) on echocardiographic endpoints only.

MeSH: Aged · Double-Blind Method · Female · Humans · Male · Middle Aged · Mitral Valve Annuloplasty · Mitral Valve Insufficiency · Proof of Concept Study · Severity of Illness Index · Ventricular Remodeling

Cards (3)

Card 1 — REDUCE FMR: Carillon reduced regurgitant volume and ventricular volumes versus sham (Witte 2019, n = 120 randomised)

Study: Randomised double-blind sham-controlled trial (n = 120 randomised)

Population: 120 patients (69.8 ± 9.5 years) with symptomatic functional mitral regurgitation receiving optimal heart-failure medical therapy, randomised blinded to the Carillon Mitral Contour System (Cardiac Dimensions, named as published; n = 87) or a sham procedure (n = 33). The prespecified primary endpoint was change in mitral regurgitant volume at 12 months by quantitative echocardiography, analysed by intention to treat.

Summary: REDUCE FMR: Carillon reduced regurgitant volume and ventricular volumes versus sham (Witte 2019, n = 120 randomised)

Result: The device was implanted in 73 of 87 assigned patients (84%). Regurgitant volume decreased by 7.1 mL/beat (95% CI −11.7 to −2.5) in the treatment group and increased by 3.3 mL/beat (95% CI −6.0 to 12.6) in the control group (P = 0.049). Left ventricular end-diastolic volume decreased by 10.4 mL (95% CI −18.5 to −2.4) versus an increase of 6.5 mL (95% CI −5.1 to 18.2) (P = 0.03), and end-systolic volume decreased by 6.2 mL versus an increase of 6.1 mL (P = 0.04) — measured volume changes, stated neutrally; the trial reports no mortality or hospitalisation comparison.

Watch out: The primary-endpoint P value is 0.049 in a 120-patient proof-of-concept trial with a 3:1 allocation and a 16% implant-failure rate; the endpoints are echocardiographic, not clinical events. A sham control is a real strength, but one borderline trial is the whole controlled evidence base.

Source: Witte KK et al. The REDUCE FMR Trial: A Randomized Sham-Controlled Study of Percutaneous Mitral Annuloplasty in Functional Mitral Regurgitation. JACC. Heart Failure. 2019. PMID: 31521683. Registry ID: ClinicalTrials.gov NCT02325830. MeSH: Aged · Double-Blind Method · Female · Humans · Male · Middle Aged · Mitral Valve Annuloplasty · Mitral Valve Insufficiency · Proof of Concept Study · Severity of Illness Index · Ventricular Remodeling

Card 2 — TITAN II: the modified Carillon device improved echocardiographic and functional measures in a single-arm study (Lipiecki 2016, n = 36)

Study: Prospective single-arm study (n = 36 treated)

Population: 36 patients with congestive heart failure, ejection fraction <40% and at least moderate functional mitral regurgitation, implanted with a modified version of the Carillon device designed to address the anchor fractures seen in earlier studies. Single-arm evaluation of safety and efficacy.

Summary: TITAN II: the modified Carillon device improved echocardiographic and functional measures in a single-arm study (Lipiecki 2016, n = 36)

Result: There was 1 major adverse event within 30 days — a death occurring 17 days after implant, assessed as not device-related. Reductions in functional mitral regurgitation and improvements in functional class and 6-minute walk tests were seen, similar to prior Carillon studies, and no device fractures in the high-strain region of the proximal anchor were observed with the modified design. The record reports these outcomes qualitatively, without the numeric changes, so none are printed.

Watch out: Single-arm, 36 patients, qualitative reporting: this card documents feasibility and the anchor-fracture fix, not efficacy. The record carries no MeSH list, so none is printed.

Source: Lipiecki J et al. Coronary sinus-based percutaneous annuloplasty as treatment for functional mitral regurgitation: the TITAN II trial. Open Heart. 2016. PMID: 27493761. Registry ID: not stated in the record. MeSH: none listed in the record

Card 3 — Synthesis: an echocardiographic win in one small sham-controlled trial — POSSIBLE (benefit)

Study: Synthesis

Population: Documented N = 156 (120 randomised + 36 single-arm); the studies do not overlap.

Summary: Synthesis: an echocardiographic win in one small sham-controlled trial — POSSIBLE (benefit)

Result: The controlled evidence is a single 120-patient trial whose regurgitant-volume and ventricular-volume endpoints both favoured the device, the primary at P = 0.049. The single-arm study is consistent in direction and confirms the modified device addressed the earlier fracture problem. No carded study reports death, hospitalisation or durability beyond 12 months.

Watch out: One randomised trial plus one small single-arm study is tier C by the two-trial discipline applied in this build-out (the second study is uncontrolled). Clinical-outcome benefit is untested, not disproven.