Nocturnal temperature-controlled laminar airflow for persistent atopic asthma (1 randomised trial, documented N = 312 randomised, 282 in the primary analysis): quality-of-life responder rates were 76% versus 61% at 1 year, a 14.8% absolute difference — significant overall, borderline (p = 0.059) in the powered subgroup aged 12 and older
Shelf #9658 · Lungs, breathing & sleep
POSSIBLE (benefit): one double-blind placebo-device trial (312 randomised) found a 14.8% higher quality-of-life responder rate on active treatment (p = 0.02), with less airway inflammation on exhaled nitric oxide — but the difference in the subgroup the trial was powered on (age 12 and older) was borderline (p = 0.059), and a single device trial cannot carry more than POSSIBLE
Stamped: 2026-11-28.
Evidence published: 2012.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients aged 7–70 with inadequately controlled persistent atopic asthma, does a bedside temperature-controlled laminar airflow device (the tested device class delivers cooled, filtered air downward over the sleeping patient, displacing inhalant allergens from the breathing zone overnight) improve asthma quality of life over 1 year versus a placebo device?
Balance of the evidence
POSSIBLE (benefit) — Composition: 1 randomised double-blind placebo-controlled trial, documented N = 312 randomised, 282 with devices installed and in the primary efficacy analysis. Responders (asthma quality-of-life gain of at least 0.5 points at 1 year): 143 of 189 (76%) on active temperature-controlled laminar airflow versus 56 of 92 (61%) on placebo, difference 14.8% (95% CI 3.1 to 26.5; p = 0.02). In patients aged 12 and older, on whom the study was powered, the difference was 14.1% (95% CI 0.6 to 27.7; p = 0.059). Exhaled nitric oxide fell by 7.1 ppb more on active treatment (95% CI −13.6 to −0.7; p = 0.03) — a neutral statement of the marker change; cat-specific IgE rose less. Adverse-event rates did not differ. Boundary: live #4148 covers house-dust-mite avoidance measures (49 trials, no effect) — avoidance bedding and encasings, not an active airflow device — and no live or pack shelf cards this trial or its PMID. POSSIBLE (benefit): a positive primary analysis whose powered subgroup only just missed significance is the definition of a POSSIBLE shelf.
MeSH: Adolescent · Adult · Aged · Air Movements · Allergens · Anti-Asthmatic Agents · Asthma · Child · Double-Blind Method · Drug Administration Schedule · Environment, Controlled · Female · Humans · Immunoglobulin E · Inhalation Exposure · Lung · Male · Middle Aged · Quality of Life · Sleep · Temperature · Treatment Outcome · Young Adult
Cards (2)
Card 1 — Laminar airflow versus placebo device: quality-of-life responders 76% versus 61% at 1 year (Boyle 2012, n = 312 randomised)
Study: Randomised double-blind placebo-controlled device trial (n = 312 randomised, 282 analysed)
Population: Three hundred twelve patients aged 7–70 with inadequately controlled persistent atopic asthma at 19 European asthma clinics, randomised to an active or placebo temperature-controlled laminar airflow device installed in the bedroom for 1 year; 282 (90%) had devices successfully installed and form the primary efficacy analysis. Primary outcome: the proportion gaining at least 0.5 points on the asthma quality-of-life score.
Summary: Laminar airflow versus placebo device: quality-of-life responders 76% versus 61% at 1 year (Boyle 2012, n = 312 randomised)
Result: Responder rates were 143 of 189 (76%) on active treatment versus 56 of 92 (61%) on placebo — difference 14.8% (95% CI 3.1 to 26.5; p = 0.02). In patients aged 12 and older, the subgroup the study was powered on, responders were 106 of 143 (74%) versus 42 of 70 (60%), difference 14.1% (0.6 to 27.7; p = 0.059). Fractional exhaled nitric oxide changed by −7.1 ppb relative to placebo (−13.6 to −0.7; p = 0.03), and cat-specific IgE increased less on active treatment. There was no difference in adverse-event rates.
Watch out: The headline significance lives in the pooled age range; in the powered 12-and-older subgroup the same-sized difference is p = 0.059, and 10% of randomised patients never had a working device installed.
Source: Boyle RJ et al. Nocturnal temperature controlled laminar airflow for treating atopic asthma: a randomised controlled trial.. Thorax. 2012. PMID: 22131290. Registry ID: NCT00986323. MeSH: Adolescent · Adult · Aged · Air Movements · Allergens · Anti-Asthmatic Agents · Asthma · Child · Double-Blind Method · Drug Administration Schedule · Environment, Controlled · Female · Humans · Immunoglobulin E · Inhalation Exposure · Lung · Male · Middle Aged · Quality of Life · Sleep · Temperature · Treatment Outcome · Young Adult
Card 2 — Synthesis — the one avoidance strategy with a positive blinded trial is a machine, not a mattress cover
Study: Synthesis
Population: Synthesis of the report carded on this shelf; no additional source.
Summary: Synthesis — the one avoidance strategy with a positive blinded trial is a machine, not a mattress cover
Result: Allergen-avoidance advice has a long null history in asthma (live #4148: 49 mite-avoidance trials, no effect). This device trial is the exception that tests a different mechanism — continuously displacing allergen-laden air from the breathing zone all night, against a placebo device, double-blind — and it produced a modest quality-of-life responder advantage plus a concordant fall in exhaled nitric oxide. One trial, one borderline powered subgroup, one device class: POSSIBLE (benefit), awaiting replication that has not been carded anywhere in this library because it does not exist in the record searched.
Watch out: Quality of life is the only clinical endpoint that separated; the record reports no exacerbation or lung-function win, so the benefit claim is a symptom-experience claim only.
Source: Synthesis of the report carded above; no additional source.