SourceMed · Shelf #9674 in the ask interface

Magnetic resonance enterography versus small-bowel ultrasound for Crohn's disease extent and activity (METRIC) — 284 patients: sensitivity for disease extent 80% versus 70%, specificity 95% versus 81% (labelled in words)

Shelf #9674 · Liver & gut

POSSIBLE — Tier C: a single multicentre diagnostic accuracy trial (284 patients); accuracy shelves are Tier C by rule

Stamped: 2026-11-28.

Evidence published: 2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with newly diagnosed or relapsing Crohn's disease, how accurately do magnetic resonance enterography and small-bowel ultrasound each detect the presence, extent and activity of small-bowel disease against a panel reference standard — and which is more accurate?

Balance of the evidence

POSSIBLE — Composition: 1 multicentre diagnostic accuracy trial, 284 patients completing the trial (133 newly diagnosed, 151 with suspected relapse), each undergoing both magnetic resonance enterography (MRE) and small-bowel ultrasound against a construct panel reference standard. For small-bowel disease extent, sensitivity was 80% for MRE versus 70% for ultrasound and specificity was 95% versus 81% (sensitivity and specificity labelled in words at first occurrence); for disease presence, sensitivity was 97% versus 92% and specificity 96% versus 84%. Tier C: a single accuracy study carries this shelf. POSSIBLE: both tests are accurate first-line investigations, and in this trial MRE was significantly more sensitive and more specific than ultrasound for mapping small-bowel Crohn's disease — a difference in test accuracy, not yet a demonstrated difference in patient outcomes.

MeSH: Adolescent · Adult · Crohn Disease · Female · Humans · Intestine, Small · Magnetic Resonance Imaging · Male · Middle Aged · Prospective Studies · Recurrence · Sensitivity and Specificity · Ultrasonography · Young Adult

Cards (2)

Card 1 — METRIC (Taylor 2018): MRE beat ultrasound on extent — sensitivity 80% versus 70% (difference 10 points, P = 0.027), specificity 95% versus 81% (difference 14 points, P = 0.039)

Study: Multicentre diagnostic accuracy trial (paired design)

Population: 284 patients aged 16 years or older with newly diagnosed Crohn's disease (133) or established disease with suspected relapse (151), recruited at 8 UK hospitals; 233 (82%) had small-bowel Crohn's disease on the reference standard (Taylor SA et al., The Lancet Gastroenterology & Hepatology 2018).

Summary: METRIC (Taylor 2018): MRE beat ultrasound on extent — sensitivity 80% versus 70% (difference 10 points, P = 0.027), specificity 95% versus 81% (difference 14 points, P = 0.039)

Result: Against the panel reference standard, MRE sensitivity for small-bowel disease extent was 80% (95% CI 72–86) versus 70% (62–78) for ultrasound — a 10% difference (95% CI 1–18; P = 0.027); specificity for extent was 95% (85–98) versus 81% (64–91) — a 14% difference (1–27; P = 0.039). For disease presence, sensitivity was 97% (91–99) versus 92% (84–96) and specificity 96% (86–99) versus 84% (65–94). Sensitivity and specificity are labelled in words here at first occurrence. There were no serious adverse events.

Watch out: The reference standard is a constructed panel diagnosis that itself used imaging and follow-up data, which can flatter both tests. Ultrasound accuracy is operator-dependent; these results come from trial sonographers/radiologists in a UK NHS setting and may not transport to less specialised services. The trial compared accuracy, not downstream treatment decisions or outcomes.

Source: Taylor SA, Mallett S, Bhatnagar G, et al. Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial. The Lancet Gastroenterology & Hepatology 2018. PMID: 29914843. Registry ID: ISRCTN03982913.

Card 2 — Synthesis: one large paired accuracy trial — MRE maps small-bowel Crohn's more accurately than ultrasound, and both clear the bar as first-line tests

Study: Synthesis

Population: 284 patients in the single carded trial.

Summary: Synthesis: one large paired accuracy trial — MRE maps small-bowel Crohn's more accurately than ultrasound, and both clear the bar as first-line tests

Result: The comparative accuracy evidence is this one trial. Its paired design (every patient had both tests) makes the head-to-head differences — about 10 points of sensitivity and 14 points of specificity for disease extent, in MRE's favour — internally solid, but there is no second accuracy trial of this size to confirm transportability.

Watch out: Tier C — single-study accuracy shelf. A companion METRIC report on patient acceptability and burden exists in the same programme; it is not carded here because this shelf asks the accuracy question only.

Source: Synthesis of the single carded trial (PMID 29914843). No additional publications carded.