CorCap cardiac support device (passive ventricular constraint) in heart failure — 300 patients in the Acorn randomised trial: ventricular volumes fell and functional class improved more than with medical therapy alone, and survival did not differ at 5 years
Shelf #9750 · Heart, vessels, blood pressure & clotting
POSSIBLE (benefit on remodelling and symptoms; the treatment made no difference to survival)
Stamped: 2026-11-28.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with dilated heart failure, does implanting the CorCap cardiac support device — a mesh jacket that passively constrains the ventricles — on top of medical therapy (with mitral surgery where indicated) improve ventricular size and shape, symptoms and survival compared with medical therapy (and mitral surgery) alone?
Balance of the evidence
POSSIBLE (benefit on remodelling and symptoms; the treatment made no difference to survival) — Composition: 1 randomised trial (300 patients) reported at 3 years for echocardiographic remodelling and at 5 years for the no-mitral-surgery stratum (107 patients); the two carded reports describe the same trial and its patients are counted once, as 300. Ventricular end-diastolic and end-systolic volumes fell significantly more with the device (average differences 18.8 mL and 15.6 mL) and sphericity index rose, sustained to 3 years; at 5 years in the no-mitral stratum, more device patients had improved by at least one functional class (p = 0.0005), adverse-event rates did not differ, and overall survival was similar between groups. Tier C: a single randomised trial. POSSIBLE (benefit on remodelling and symptoms; the treatment made no difference to survival): the remodelling the device was designed to produce is documented, the symptom signal is favourable, and the survival question is answered neutrally within this trial's size. The tested product is the CorCap Cardiac Support Device (Acorn Cardiovascular, Inc, St Paul, Minn, USA), named as the publications give it.
MeSH: Aged · Aged, 80 and over · Echocardiography, Doppler · Equipment Design · Equipment Safety · Female · Follow-Up Studies · Heart Failure · Heart-Assist Devices · Humans · Longitudinal Studies · Male · Middle Aged · Probability · Reference Values · Regression Analysis · Risk Assessment · Severity of Illness Index · Stroke Volume · Survival Analysis · Time Factors · Treatment Outcome · Ventricular Dysfunction, Left · Ventricular Remodeling · Biomechanical Phenomena · Kaplan-Meier Estimate · Prospective Studies · Prosthesis Design · Recovery of Function · Risk Factors · Stress, Mechanical · United States · Ventricular Function, Left
Cards (3)
Card 1 — Acorn trial, 3-year echocardiographic results: ventricular volumes fell significantly more with CorCap (end-diastolic −18.8 mL, end-systolic −15.6 mL average differences) and the ventricle became less spherical (Starling 2007, 300 patients)
Study: Randomised controlled trial (imaging outcomes)
Population: 300 patients with heart failure randomised in the Acorn trial to the CorCap cardiac support device (Acorn Cardiovascular, Inc, St Paul, Minn, USA — named as the publication gives it) plus medical therapy, with or without mitral valve surgery as clinically indicated, versus the same care without the device; echocardiograms were read blinded at a core laboratory.
Summary: Acorn trial, 3-year echocardiographic results: ventricular volumes fell significantly more with CorCap (end-diastolic −18.8 mL, end-systolic −15.6 mL average differences) and the ventricle became less spherical (Starling 2007, 300 patients)
Result: Patients treated with the device had significant reductions in left ventricular end-diastolic volume (average difference 18.8 mL; p = 0.005) and end-systolic volume (average difference 15.6 mL; p = 0.013) compared with control, and sphericity index increased significantly (average difference 0.045 units; p = 0.018). The improvements were maintained over 3 years and were seen whether the device was implanted with mitral surgery or alone.
Watch out: Remodelling endpoints, not clinical events; part of the cohort received mitral surgery in both arms, and this report does not separate a device effect on death or hospitalisation. No registry ID is stated in the record (the trial predates routine registration reporting in the record).
Source: PMID: 17888975
Card 2 — Acorn trial, 5-year results in the no-mitral-surgery stratum: survival similar, functional class improved more with CorCap (p = 0.0005), adverse events no different (Mann 2012, 107 patients in this stratum)
Study: Randomised controlled trial (5-year follow-up report)
Population: 107 of the trial's 300 patients — the stratum not undergoing mitral valve repair or replacement: 57 randomised to CorCap plus optimal medical therapy and 50 to optimal medical therapy alone, followed annually to 5 years.
Summary: Acorn trial, 5-year results in the no-mitral-surgery stratum: survival similar, functional class improved more with CorCap (p = 0.0005), adverse events no different (Mann 2012, 107 patients in this stratum)
Result: Overall survival was similar between the treatment and control groups, with no late adverse effect on mortality. The treatment group had significant reductions in left ventricular end-diastolic volume (p = 0.029) and a small increase in sphericity index, and more patients improved by at least one NYHA functional class (p = 0.0005). Rates of adverse events did not differ.
Watch out: This is a stratum of the same 300-patient trial carded above, not a second trial; 107 patients cannot exclude a moderate survival effect in either direction. No registry ID is stated in the record.
Source: PMID: 21762937
Card 3 — Synthesis: one trial — the ventricle shrank and symptoms improved; survival was unchanged
Study: Synthesis
Population: 300 randomised patients in total (counted once across the two reports).
Summary: Synthesis: one trial — the ventricle shrank and symptoms improved; survival was unchanged
Result: The Acorn trial is internally consistent: passive constraint produced durable reverse remodelling and a functional-class advantage, with no survival difference and no excess adverse events over 5 years. It remains a single trial of a device that did not enter routine practice, with no confirmatory study in the carded records.
Watch out: Functional-class assessment in a surgical device trial cannot be fully blinded; the volume changes, read blinded at a core laboratory, are the firmer finding.
Source: Synthesis of PMID: 17888975 and PMID: 21762937