SourceMed · Shelf #9773 in the ask interface
308-nm excimer light/laser for vitiligo (4 reports; 411 patients in the largest pooled analysis): head-to-head trials found faster, more complete repigmentation than targeted narrowband UVB, while pooled lamp comparisons found no difference from laser or narrowband UVB
Shelf #9773 · Eyes, skin, nose & allergy
SPLIT (by comparison) — within-patient randomised trials favour 308-nm excimer light over targeted narrowband UVB (faster and more complete repigmentation), pooled comparisons find the excimer lamp no different from the excimer laser or narrowband UVB, and adding a topical calcineurin inhibitor to excimer treatment improves success over excimer alone (relative risk 1.93)
Stamped: 2026-11-28.
Evidence published: 2007–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people with vitiligo, does targeted 308-nm excimer light or laser repigment lesions better or faster than narrowband UVB or other phototherapy — and does adding a topical calcineurin inhibitor to excimer treatment beat excimer alone?
Balance of the evidence
SPLIT (by comparison) — Composition: 2 within-patient randomised trials (21 and 36 patients with symmetrical lesions) and 2 systematic reviews/meta-analyses (6 studies, 411 patients; 8 randomised trials, 425 patches/patients; pools overlap and are not added). Against targeted narrowband UVB, excimer light won both head-to-head trials: excellent repigmentation in 37.5% of excimer-treated lesions versus 6% of narrowband-UVB lesions in the multicentre trial, and excellent repigmentation in 25% versus 13.89% with a lower Vitiligo Area Scoring Index in the 48-session trial, with 25% repigmentation reached in a mean of 19.42 versus 26.25 sessions. In the pooled device comparison, the excimer lamp did not differ significantly from the excimer laser (risk ratio 0.97 for at least 50% repigmentation) or from narrowband UVB (risk ratio 1.14). Adding a topical calcineurin inhibitor to excimer treatment raised treatment success (at least 75% repigmentation) over excimer alone (relative risk 1.93, 95% CI 1.28 to 2.91; number needed to treat 4.5); vitamin D analogues and corticosteroid combinations were not supported. Adverse effects were mild (itching, burning, dryness, phototoxicity) and did not stop treatment. SPLIT (by comparison): excimer light is a faster targeted option than narrowband UVB for localised lesions and works better with a calcineurin inhibitor added, but the pooled record does not show the lamp beating the laser or whole-body narrowband UVB on final repigmentation.
MeSH: Adolescent · Adult · Female · Humans · Laser Therapy · Male · Middle Aged · Statistics, Nonparametric · Treatment Outcome · Ultraviolet Therapy · Vitiligo · Aged · Lasers, Excimer · Low-Level Light Therapy · Phototherapy · Randomized Controlled Trials as Topic · Skin Pigmentation · Administration, Topical · Adrenal Cortex Hormones · Calcineurin Inhibitors · Combined Modality Therapy · Follow-Up Studies · Risk Assessment · Severity of Illness Index
Cards (5)
Card 1 — Multicentre within-patient trial, 21 patients: excellent repigmentation in 37.5% of excimer-light lesions versus 6% of narrowband-UVB lesions over 6 months (Casacci 2007)
Study: Randomised within-patient (half-side) controlled trial
Population: 21 patients with symmetrical vitiligo lesions; lesions on one body side treated twice weekly for 6 months with 308-nm monochromatic excimer light, the opposite side with narrowband UVB (311-313 nm), in a randomised, investigator-blinded, half-side comparison.
Summary: Multicentre within-patient trial, 21 patients: excellent repigmentation in 37.5% of excimer-light lesions versus 6% of narrowband-UVB lesions over 6 months (Casacci 2007)
Result: Six lesions (37.5%) treated with excimer light and one lesion (6%) treated with narrowband UVB achieved excellent repigmentation (score 4); good repigmentation (score 3) was seen in 25% of excimer lesions and 31% of narrowband-UVB lesions. The authors conclude excimer light is more effective and induces repigmentation more rapidly.
Watch out: Only 21 patients and lesion-level denominators (16 lesions assessed per side in the percentages printed); within-patient designs remove between-person confounding but cannot test whole-body outcomes, and follow-up ends at 6 months.
Source: Casacci M et al. Journal of the European Academy of Dermatology and Venereology. 2007. PMID: 17659006. Registry ID: not stated in the record. MeSH: Adolescent · Adult · Female · Humans · Laser Therapy · Male · Middle Aged · Statistics, Nonparametric · Treatment Outcome · Ultraviolet Therapy · Vitiligo
Card 2 — Randomised single-blind trial, 36 paired lesions: excimer light beat targeted narrowband UVB on repigmentation grade and speed over 48 sessions (Poolsuwan 2021)
Study: Randomised within-patient single-blind comparison study
Population: Patients with symmetrical vitiligo lesions on the same anatomical area; 36 symmetrically paired lesions, one side randomised to localised 308-nm excimer light and the other to targeted 311-nm narrowband UVB, treated with the same protocol for 48 sessions.
Summary: Randomised single-blind trial, 36 paired lesions: excimer light beat targeted narrowband UVB on repigmentation grade and speed over 48 sessions (Poolsuwan 2021)
Result: After 48 sessions the excimer side had a significantly lower Vitiligo Area Scoring Index and a higher repigmentation grade (P < .001); excellent repigmentation in 9 lesions (25%) on excimer versus 5 (13.89%) on narrowband UVB. Time to 25% repigmentation averaged 19.42 versus 26.25 sessions (P = .002). Mean cumulative UV dose did not differ significantly (P = .065) and phototoxicity was similar on both sides (P = .08).
Watch out: Lesions, not patients, are the unit randomised and analysed; results apply to localised symmetrical disease treated for 48 sessions, not to extensive vitiligo.
Source: Poolsuwan P et al. Photodermatology, Photoimmunology & Photomedicine. 2021. PMID: 33047405. Registry ID: not stated in the record. MeSH: Adult · Aged · Female · Humans · Lasers, Excimer · Male · Middle Aged · Ultraviolet Therapy · Vitiligo
Card 3 — Meta-analysis, 6 studies / 411 patients: excimer lamp did not differ significantly from excimer laser or narrowband UVB on repigmentation (Lopes 2016)
Study: Systematic review and meta-analysis of randomised trials
Population: Systematic review and meta-analysis of randomised controlled trials comparing 308-nm monochromatic excimer lamps with excimer laser or narrowband UVB in vitiligo patients of any age (6 studies, 411 patients, 764 lesions).
Summary: Meta-analysis, 6 studies / 411 patients: excimer lamp did not differ significantly from excimer laser or narrowband UVB on repigmentation (Lopes 2016)
Result: For at least 50% repigmentation, excimer lamp versus excimer laser risk ratio 0.97 (95% CI 0.84 to 1.11) and versus narrowband UVB risk ratio 1.14 (95% CI 0.88 to 1.48); for at least 75% repigmentation, risk ratio 0.96 (95% CI 0.71 to 1.30) versus laser and 1.81 (95% CI 0.11 to 29.52) versus narrowband UVB — none significant. Adverse effects were mild (itching, burning, dryness) and none interrupted treatment.
Watch out: The lamp-versus-narrowband estimate for at least 75% repigmentation rests on very wide intervals (0.11 to 29.52); absence of a significant difference in six small studies is not proof of equivalence.
Source: Lopes C et al. American Journal of Clinical Dermatology. 2016. PMID: 26520641. Registry ID: PROSPERO CRD42014015237, as printed in the record. MeSH: Female · Humans · Lasers, Excimer · Low-Level Light Therapy · Male · Phototherapy · Randomized Controlled Trials as Topic · Skin Pigmentation · Treatment Outcome · Ultraviolet Therapy · Vitiligo
Card 4 — Meta-analysis, 8 randomised trials / 425 patches or patients: adding a topical calcineurin inhibitor to excimer treatment beat excimer alone (relative risk 1.93) (Bae 2016)
Study: Systematic review and meta-analysis of randomised trials
Population: Systematic review and meta-analysis of randomised trials of 308-nm excimer laser/light combined with topical agents versus excimer monotherapy for vitiligo (8 trials, 425 patches/patients).
Summary: Meta-analysis, 8 randomised trials / 425 patches or patients: adding a topical calcineurin inhibitor to excimer treatment beat excimer alone (relative risk 1.93) (Bae 2016)
Result: Excimer plus topical calcineurin inhibitors (4 studies) was superior to excimer alone for treatment success (at least 75% repigmentation): relative risk 1.93 (95% CI 1.28 to 2.91), number needed to treat 4.5 (95% CI 2.9 to 10). Evidence was insufficient to support adding topical vitamin D3 analogues (3 studies) or corticosteroids (1 study).
Watch out: The pooled unit mixes patches and patients across small heterogeneous trials; the calcineurin finding rests on 4 studies and the record itself flags heterogeneity as a limitation.
Source: Bae JM et al. Journal of the American Academy of Dermatology. 2016. PMID: 26785803. Registry ID: not stated in the record. MeSH: Administration, Topical · Adrenal Cortex Hormones · Calcineurin Inhibitors · Combined Modality Therapy · Female · Follow-Up Studies · Humans · Lasers, Excimer · Male · Phototherapy · Randomized Controlled Trials as Topic · Risk Assessment · Severity of Illness Index · Treatment Outcome · Vitiligo
Card 5 — Synthesis: excimer light is faster than targeted narrowband UVB in head-to-head trials and gains from an added calcineurin inhibitor, but pooled final repigmentation does not separate the lamp from the laser or narrowband UVB
Study: Synthesis
Population: Across the 4 reports carded above (2 within-patient randomised trials; 2 meta-analyses whose pools overlap).
Summary: Synthesis: excimer light is faster than targeted narrowband UVB in head-to-head trials and gains from an added calcineurin inhibitor, but pooled final repigmentation does not separate the lamp from the laser or narrowband UVB
Result: Direction depends on the comparison: speed and excellent-repigmentation rates favour excimer over targeted narrowband UVB in both direct trials; device-versus-device pooling is neutral; combination with a calcineurin inhibitor is the clearest positive signal (relative risk 1.93). No carded record tests excimer treatment against no treatment, so the shelf cannot separate device effects from spontaneous or context effects.
Watch out: All direct trials are within-patient lesion comparisons in localised disease; durability after treatment stops is not reported in any carded record.
Source: Synthesis of the reports carded above; no additional source.