SourceMed · Shelf #9775 in the ask interface
Implantable collamer lens versus SMILE laser surgery for high myopia (3 reports; 1,390 eyes in the largest pooled analysis): pooled comparisons favour the lens on safety index and corrected-vision gains, with more halos; the lens's own FDA trial is single-arm
Shelf #9775 · Eyes, skin, nose & allergy
POSSIBLE (benefit) — two meta-analyses of non-randomised comparative studies favour the implantable collamer lens over SMILE on safety index and gains in corrected vision, with equal predictability and a higher risk of halos (relative risk 1.79); no randomised head-to-head trial exists in the carded record, and the lens's pivotal FDA cohort (526 eyes) is single-arm
Stamped: 2026-11-28.
Evidence published: 2004–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with moderate to high myopia, does implanting a posterior-chamber phakic implantable collamer lens correct vision as safely and effectively as small incision lenticule extraction (SMILE) corneal laser surgery?
Balance of the evidence
POSSIBLE (benefit) — Composition: 2 systematic reviews/meta-analyses of comparative (observational) studies (5 studies, 555 eyes; 12 studies, 1,390 eyes of 822 patients; pools overlap and are not added) and 1 prospective single-arm FDA trial cohort (526 eyes of 294 patients). In the 5-study pool (refraction -6 to -12 dioptres), the lens beat SMILE on efficacy index (mean difference 0.09, 95% CI 0.01 to 0.16) and safety index (mean difference 0.08, 95% CI 0.00 to 0.16); more lens eyes gained one or more lines of corrected vision (relative risk 1.54) and fewer lost lines (relative risk 0.17), predictability did not differ, and halos were commoner with the lens (relative risk 1.79, 95% CI 1.48 to 2.16). In the 12-study pool of the V4c lens, the safety-index and aberration advantages were significant mainly at shorter follow-up and became non-significant beyond 6 months, with no difference in efficacy index or postoperative refraction. In the FDA cohort at 3 years, 94.7% of targeted eyes saw 20/40 or better uncorrected, 67.5% were within 0.5 dioptres of prediction, cumulative endothelial cell loss was under 10%, 2.7% had early anterior subcapsular opacities (2 clinically significant), and 0.6% had the lens removed with cataract extraction. POSSIBLE (benefit): on the non-randomised record the lens matches or modestly beats SMILE on vision quality for high myopia, at the price of halos and a small cataract signal that only the single-arm cohort quantifies.
MeSH: Adult · Anterior Chamber · Cell Count · Contact Lenses · Contrast Sensitivity · Endothelium, Corneal · Female · Follow-Up Studies · Humans · Male · Middle Aged · Myopia · Patient Satisfaction · Postoperative Complications · Prospective Studies · Prosthesis Design · Prosthesis Implantation · Safety · Treatment Outcome · United States · United States Food and Drug Administration · Visual Acuity · Lenses, Intraocular · Refraction, Ocular · Lasers · Lens Implantation, Intraocular
Cards (4)
Card 1 — FDA trial cohort, 526 eyes / 294 patients: 94.7% saw 20/40 or better uncorrected at 3 years; 0.6% needed lens removal with cataract extraction (Sanders 2004)
Study: Prospective single-arm clinical trial (FDA pivotal cohort)
Population: Prospective non-randomised US FDA clinical trial of the myopic implantable collamer lens in 294 patients (526 eyes) with 3.0 to 20.0 dioptres of myopia, followed for 3 years. The tested product is the Visian Implantable Collamer Lens (STAAR Surgical), named in the record for clarification; it is an implantable device, not a drug.
Summary: FDA trial cohort, 526 eyes / 294 patients: 94.7% saw 20/40 or better uncorrected at 3 years; 0.6% needed lens removal with cataract extraction (Sanders 2004)
Result: At 3 years, 59.3% had 20/20 or better and 94.7% had 20/40 or better uncorrected acuity (in eyes with 20/20 best-corrected acuity targeted for emmetropia); 67.5% were within 0.5 dioptres and 88.2% within 1.0 dioptre of predicted refraction. Three eyes (0.8%) lost 2 or more lines of best-corrected acuity while 40 eyes (10.8%) gained similarly. Cumulative endothelial cell loss was under 10%; early anterior subcapsular opacities (trace or greater) occurred in 14 eyes (2.7%), 2 clinically significant; 5 eyes (0.9%) developed nuclear opacities grade above 2 at 2-3 years; 3 eyes (0.6%) had lens removal with cataract extraction and intraocular lens implantation. 97.1% of patients said they would choose the implant again.
Watch out: No comparator arm: every comparative claim on this shelf comes from the observational meta-analyses, not from this cohort. The record's own MeSH list includes the descriptor 'Contact Lenses' for an implantable lens — reproduced as printed.
Source: Sanders DR et al. Ophthalmology. 2004. PMID: 15350323. Registry ID: not stated in the record. MeSH: Adult · Anterior Chamber · Cell Count · Contact Lenses · Contrast Sensitivity · Endothelium, Corneal · Female · Follow-Up Studies · Humans · Male · Middle Aged · Myopia · Patient Satisfaction · Postoperative Complications · Prospective Studies · Prosthesis Design · Prosthesis Implantation · Safety · Treatment Outcome · United States · United States Food and Drug Administration · Visual Acuity
Card 2 — Meta-analysis, 5 observational studies / 555 eyes: lens beat SMILE on efficacy and safety indices and corrected-vision gains, with more halos (relative risk 1.79) (Cao 2021)
Study: Systematic review and meta-analysis of observational comparative studies
Population: Systematic review and meta-analysis of studies comparing implantable collamer lens implantation with SMILE for high myopia in adults (5 observational studies, 555 eyes; refraction -6 to -12 dioptres; follow-up mostly 6-12 months).
Summary: Meta-analysis, 5 observational studies / 555 eyes: lens beat SMILE on efficacy and safety indices and corrected-vision gains, with more halos (relative risk 1.79) (Cao 2021)
Result: Lens versus SMILE: efficacy index mean difference 0.09 (95% CI 0.01 to 0.16), safety index mean difference 0.08 (95% CI 0.00 to 0.16); gained one or more lines of corrected acuity relative risk 1.54 (95% CI 1.28 to 1.86), gained two or more lines relative risk 2.09 (95% CI 1.40 to 3.13), lost one or more lines relative risk 0.17 (95% CI 0.05 to 0.63). Predictability did not differ. Halos were commoner with the lens (relative risk 1.79, 95% CI 1.48 to 2.16); total higher-order aberrations rose less with the lens (mean difference -0.23).
Watch out: All 5 studies are observational, so eye selection (corneal thickness, refraction depth) differs systematically between lens and laser patients; the halo relative risk is printed with the vision-gain relative risks alongside, as the record gives no absolute halo rates.
Source: Cao K et al. BMC Ophthalmology. 2021. PMID: 34961514. Registry ID: not stated in the record. MeSH: Adult · Humans · Lenses, Intraocular · Myopia · Refraction, Ocular · Treatment Outcome · Visual Acuity
Card 3 — Meta-analysis, 12 studies / 1,390 eyes: V4c lens advantages on safety index and aberrations were early and faded beyond 6 months (Chen 2022)
Study: Systematic review and meta-analysis of comparative studies
Population: Systematic review and meta-analysis comparing femtosecond laser-assisted SMILE with Visian Implantable Collamer Lens V4c implantation (STAAR Surgical, named in the record) for moderate to high myopia (12 studies, 1,390 eyes of 822 patients).
Summary: Meta-analysis, 12 studies / 1,390 eyes: V4c lens advantages on safety index and aberrations were early and faded beyond 6 months (Chen 2022)
Result: The V4c lens had a significantly higher safety index and lower total higher-order aberrations, coma and spherical aberration than SMILE overall (P < .05), with differences more prominent in high myopia at shorter follow-up; beyond 6 months the safety-index and total-aberration differences became non-significant (P > .05). Efficacy index, postoperative acuity, spherical equivalent, trefoil, scatter index and modulation transfer function did not differ (P > .05).
Watch out: The pooled studies are comparative cohorts, not randomised trials; the time-dependent fading of the lens advantage is a subgroup finding, and the two meta-analyses on this shelf share underlying studies.
Source: Chen D et al. Journal of Refractive Surgery. 2022. PMID: 35686713. Registry ID: not stated in the record. MeSH: Humans · Lasers · Lens Implantation, Intraocular · Lenses, Intraocular · Myopia · Refraction, Ocular
Card 4 — Synthesis: the lens matches SMILE on refractive accuracy and modestly beats it on early vision-quality measures in non-randomised comparisons, with more halos and a small long-term cataract signal
Study: Synthesis
Population: Across the 3 reports carded above (1,390 eyes in the largest comparative pool; 526 eyes in the single-arm FDA cohort).
Summary: Synthesis: the lens matches SMILE on refractive accuracy and modestly beats it on early vision-quality measures in non-randomised comparisons, with more halos and a small long-term cataract signal
Result: No randomised comparison exists in the carded record. The consistent findings are equal predictability, better corrected-vision gains with the lens, more halos with the lens, and — from the FDA cohort alone — anterior subcapsular opacities in 2.7% of eyes and lens removal with cataract surgery in 0.6% by 3 years.
Watch out: Reversibility (the lens can be removed; SMILE cannot be undone) is a structural difference the carded outcomes do not capture, and neither meta-analysis reports outcomes beyond about a year.
Source: Synthesis of the reports carded above; no additional source.