Cyclophotocoagulation for glaucoma (2 randomised trials; 78 patients): micropulse beat continuous-wave on success at 12 months in refractory glaucoma (75% versus 29%) but not at 18 months; in non-refractory disease all three cyclodestructive modalities performed alike

Shelf #9776 · Eyes, skin, nose & allergy

SPLIT (by modality and disease stage) — in refractory end-stage glaucoma micropulse achieved the pressure-success definition more often than continuous-wave at 12 months (75% versus 29%) with fewer complications, but the success gap closed by 18 months (52% versus 30%, P = 0.13) while mean pressure fell 45% in both groups; in non-refractory glaucoma a 30-patient three-way trial found no significant difference between high-intensity focused ultrasound, micropulse and continuous-wave

Stamped: 2026-11-28.

Evidence published: 2015–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In glaucoma that is refractory or medically uncontrolled, how do micropulse and continuous-wave transscleral cyclophotocoagulation (and high-intensity focused ultrasound) compare for lowering intraocular pressure, and at what complication cost?

Balance of the evidence

SPLIT (by modality and disease stage) — Composition: 2 randomised comparative trials, 78 patients in total (48 with refractory end-stage glaucoma; 30 with non-refractory medically uncontrolled primary open-angle glaucoma and good vision). In the refractory trial, success (pressure 6-21 mmHg with at least a 30% relative reduction, with or without medications) at 12 months was 75% on micropulse versus 29% on continuous-wave (P < 0.01), but at 18 months 52% versus 30% (P = 0.13); mean pressure fell by a relative 45% in both groups from baselines of 36.5 and 35.0 mmHg, retreatment and medication counts did not differ, and the ocular complication rate was higher with continuous-wave (P = 0.01). In the non-refractory trial (10 patients per arm), 6-month pressure fell by a relative 31.5% (continuous-wave), 23.9% (micropulse) and 19.4% (high-intensity focused ultrasound) (P = 0.4), with success rates of 50%, 60% and 50% (P = 0.8) and more complications, non-significantly, in the continuous-wave arm. SPLIT (by modality and disease stage): micropulse is the gentler delivery of the same pressure-lowering effect — an early success and safety edge in refractory disease, no proven durable superiority, and no separation between modalities in earlier-stage disease.

MeSH: Aged · Ciliary Body · Female · Glaucoma · Humans · Intraocular Pressure · Laser Coagulation · Lasers, Semiconductor · Male · Middle Aged · Prospective Studies · Sclera · Tertiary Care Centers · Tonometry, Ocular · Visual Acuity · Glaucoma, Open-Angle · Retrospective Studies · Treatment Outcome

Cards (3)

Card 1 — Randomised trial, 48 patients with refractory glaucoma: micropulse success 75% versus 29% for continuous-wave at 12 months, converging by 18 months (Aquino 2015)

Study: Randomised comparative exploratory trial

Population: 48 patients with refractory, end-stage glaucoma at a tertiary hospital, randomised to micropulse or continuous-wave diode transscleral cyclophotocoagulation and monitored for 18 months for pressure, acuity, medications, retreatment and complications.

Summary: Randomised trial, 48 patients with refractory glaucoma: micropulse success 75% versus 29% for continuous-wave at 12 months, converging by 18 months (Aquino 2015)

Result: Success (pressure 6-21 mmHg and at least a 30% relative reduction, with or without medications) was achieved by 75% on micropulse versus 29% on continuous-wave at 12 months (P < 0.01), and by 52% versus 30% at 18 months (P = 0.13). Mean pressure fell by a relative 45% in both groups (P = 0.70) from baselines of 36.5 mmHg (micropulse) and 35.0 mmHg (continuous-wave). Retreatment rates and medication counts did not differ significantly; the ocular complication rate was higher in continuous-wave eyes (P = 0.01), with complications including acuity decline, prolonged anterior chamber inflammation, phthisis bulbi, scleral thinning and ocular pain.

Watch out: A single exploratory trial of 48 end-stage eyes; the headline 12-month success gap is not sustained at 18 months, and mean pressure reduction — the outcome patients feel — was identical between modes.

Source: Aquino MC et al. Clinical & Experimental Ophthalmology. 2015. PMID: 24811050. Registry ID: not stated in the record. MeSH: Aged · Ciliary Body · Female · Glaucoma · Humans · Intraocular Pressure · Laser Coagulation · Lasers, Semiconductor · Male · Middle Aged · Prospective Studies · Sclera · Tertiary Care Centers · Tonometry, Ocular · Visual Acuity

Card 2 — Randomised three-way trial, 30 patients with non-refractory glaucoma: no significant difference between ultrasound, micropulse and continuous-wave cyclodestruction at 6 months (Abdullatif 2021)

Study: Prospective randomised comparative study (the record also carries a 'Retrospective Studies' MeSH descriptor — reproduced as printed)

Population: 30 patients with non-refractory, medically uncontrolled primary open-angle glaucoma and good vision at a single centre, randomised (10 per arm) to a single session of high-intensity focused ultrasound cyclocoagulation, micropulse cyclophotocoagulation or continuous-wave transscleral cyclophotocoagulation.

Summary: Randomised three-way trial, 30 patients with non-refractory glaucoma: no significant difference between ultrasound, micropulse and continuous-wave cyclodestruction at 6 months (Abdullatif 2021)

Result: At 6 months pressure fell by a relative 31.5% (continuous-wave), 23.9% (micropulse) and 19.4% (ultrasound) (P = 0.4); success (at least a 30% relative reduction with pressure 6-21 mmHg, without vision-threatening complications) was 50%, 60% and 50% respectively (P = 0.8), with fewer drops and oral acetazolamide stopped across arms. Complications were more frequent in the continuous-wave arm without reaching significance.

Watch out: Ten patients per arm cannot exclude clinically large differences; 6-month follow-up in seeing eyes is short for a destructive procedure, and the record's MeSH list mixes prospective and retrospective descriptors.

Source: Abdullatif AM et al. International Ophthalmology. 2021. PMID: 34009517. Registry ID: not stated in the record. MeSH: Ciliary Body · Glaucoma · Glaucoma, Open-Angle · Humans · Intraocular Pressure · Laser Coagulation · Lasers, Semiconductor · Prospective Studies · Retrospective Studies · Treatment Outcome

Card 3 — Synthesis: same average pressure fall across delivery modes; micropulse's advantages are earlier success in refractory disease and fewer complications, neither yet shown durable

Study: Synthesis

Population: Across the 2 randomised trials carded above (78 patients).

Summary: Synthesis: same average pressure fall across delivery modes; micropulse's advantages are earlier success in refractory disease and fewer complications, neither yet shown durable

Result: Mean pressure reduction did not differ by modality in either trial (a relative 45% fall in refractory disease; a relative 19-32% fall in non-refractory disease). What differs is the success-rate time course and the complication pattern, both favouring micropulse, on a combined base of 78 randomised patients.

Watch out: No carded trial compares any cyclodestructive procedure against drops, trabeculectomy or tube surgery; the shelf answers only which delivery mode, not whether to destroy ciliary tissue at all.

Source: Synthesis of the reports carded above; no additional source.