Bone conduction hearing devices for conductive hearing loss (2 systematic reviews; 28 studies in the transcutaneous meta-analysis, 21 studies in the unilateral-conductive review): functional hearing improved about 26-44 dB, with active transcutaneous devices ahead at high frequencies
Shelf #9780 · Eyes, skin, nose & allergy
POSSIBLE (benefit) — systematic reviews of mostly observational studies find large functional hearing gains (about 32 dB pooled for active transcutaneous devices in conductive/mixed loss; 25-44 dB range for passive devices) and better quality of life, with active devices ahead at high frequencies; no randomised comparison exists in the carded record and complication pooling gives 14.8% for active devices
Stamped: 2026-11-28.
Evidence published: 2022–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people with conductive or mixed hearing loss (including unilateral conductive loss) who cannot use a conventional air-conduction hearing aid, do implantable bone conduction devices improve hearing and quality of life — and do active transcutaneous devices outperform passive ones?
Balance of the evidence
POSSIBLE (benefit) — Composition: 2 systematic reviews (1 meta-analysis of 28 studies of transcutaneous bone conduction devices in adults; 1 review of 21 studies of bone conduction devices in unilateral conductive hearing loss; neither record states a pooled participant total, so documented N is given as study counts). In the transcutaneous meta-analysis, pooled functional hearing improvement for active devices in mixed or conductive loss was 31.8 dB (95% CI 27.7 to 35.9); passive-device improvements ranged 25.2 to 44.3 dB across studies. At high frequencies the active devices gained more (weighted gains at 4 and 6 kHz: 31.8 and 34.3 dB active versus 16.8 and 6.4 dB passive). The pooled complication rate for active devices was 14.8% (95% CI 9% to 21%); both device types improved ease of communication and background-noise understanding, and included-study quality was low overall. In unilateral conductive loss, the 21-study review found moderate threshold improvements and significantly improved speech recognition with devices, wide individual variation in sound localisation, and overall positive questionnaire results alongside some unfavourable experiences; the reviewers recommend a trial period with a non-implantable device before implantation. POSSIBLE (benefit): consistent, large audiometric gains and patient-reported benefit in the population that cannot wear ordinary aids — but the evidence is observational, device generations are mixed, and the active-versus-passive contrast is indirect.
MeSH: Adult · Bone Conduction · Hearing Aids · Hearing Loss, Conductive · Hearing Tests · Humans · Quality of Life
Cards (3)
Card 1 — Meta-analysis, 28 studies: active transcutaneous devices improved functional hearing by a pooled 31.8 dB in conductive/mixed loss, with a 14.8% pooled complication rate (Forner 2022)
Study: Systematic review and meta-analysis
Population: Systematic review and meta-analysis of observational and experimental studies of active versus passive transcutaneous bone conduction hearing devices in adults (28 studies; searches to September 2019). The record names device classes (active and passive transcutaneous) rather than single products; no single tested product is named here because the record pools classes.
Summary: Meta-analysis, 28 studies: active transcutaneous devices improved functional hearing by a pooled 31.8 dB in conductive/mixed loss, with a 14.8% pooled complication rate (Forner 2022)
Result: Pooled improvement in functional hearing for active devices in mixed or conductive hearing loss: 31.8 dB (95% CI 27.7 to 35.9; I2 = 44.6). Passive-device improvements ranged 25.2 to 44.3 dB. Weighted high-frequency gains favoured active devices (at 2, 3, 4, 6 kHz: 26.5, 25.7, 31.8, 34.3 dB active versus 26.2, 21.1, 16.8, 6.4 dB passive). Pooled complication rate for active devices 14.8% (95% CI 9% to 21%; I2 = 0%). Both types improved ease of communication, reverberation and background-noise understanding. Study quality was low overall and the reviewers state high-quality comparative studies are lacking.
Watch out: The active-versus-passive contrast is an indirect, across-study comparison of mostly case series — not a head-to-head trial — and the record states no pooled participant total, so none is printed.
Source: Forner D et al. Ear and Hearing. 2022. PMID: 34191755. Registry ID: not stated in the record. MeSH: Adult · Bone Conduction · Hearing Aids · Hearing Loss, Conductive · Hearing Tests · Humans · Quality of Life
Card 2 — Systematic review, 21 studies in unilateral conductive hearing loss: thresholds and speech recognition improved, localisation varied widely, questionnaires mostly positive (Wang 2023)
Study: Systematic review
Population: Systematic review of bone conduction devices in patients with unilateral conductive hearing loss (21 studies meeting inclusion; searches to May 2023), collecting hearing thresholds, speech recognition, sound localisation and subjective questionnaire outcomes. This record carries no MeSH list — stated here as printed; the pack's MeSH comes from the other carded record.
Summary: Systematic review, 21 studies in unilateral conductive hearing loss: thresholds and speech recognition improved, localisation varied widely, questionnaires mostly positive (Wang 2023)
Result: Moderate hearing-threshold improvements and significantly improved speech recognition were found in aided patients; sound localisation results showed wide individual variation; questionnaires showed an overall positive influence on daily life, with several unfavourable experiences reported by some patients. The reviewers conclude devices are a credible intervention for unilateral conductive loss and recommend a trial period with non-implantable bone conduction devices before final implantation.
Watch out: No pooled effect sizes or participant total are stated in the record; unilateral conductive loss is the hardest configuration for any bone-conduction benefit because the normal ear dominates, which the localisation results reflect.
Source: Wang XY et al. Journal of Clinical Medicine. 2023. PMID: 37762842. Registry ID: not stated in the record. MeSH: none listed in the record
Card 3 — Synthesis: bone conduction devices deliver large measured hearing gains for conductive loss; the open questions are comparative (which device class, which patients), not whether thresholds improve
Study: Synthesis
Population: Across the 2 systematic reviews carded above (28 and 21 studies; overlapping primary literatures).
Summary: Synthesis: bone conduction devices deliver large measured hearing gains for conductive loss; the open questions are comparative (which device class, which patients), not whether thresholds improve
Result: Threshold and speech gains are consistent and large; quality-of-life results are positive; complications are non-trivial (14.8% pooled for active transcutaneous devices). No carded record randomises patients between device classes or against conventional aids, and single-sided sensorineural deafness — a different indication with its own randomised record — is outside this shelf's question.
Watch out: Fence: cochlear implantation versus bone conduction versus CROS aids for single-sided deafness is asked by another shelf; this shelf is confined to conductive and mixed loss.
Source: Synthesis of the reports carded above; no additional source.