SourceMed · Shelf #9791 in the ask interface

Toe-brachial index and toe systolic pressure for peripheral arterial disease (1,927 participants in the Cochrane review's TBI studies; 294 patients in the earlier meta-analysis): pooled sensitivity 81% / specificity 77% (labelled in words) in the meta-analysis, but the Cochrane review rates the evidence very low certainty

Shelf #9791 · Heart, vessels, blood pressure & clotting

MEASUREMENT ACCURACY — NOT ESTABLISHED (pooled estimates exist, but the Cochrane review finds the underlying evidence very low certainty)

Stamped: 2026-11-28.

Evidence published: 2020–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults at risk of lower-limb peripheral arterial disease, how accurately do the toe-brachial index and toe systolic blood pressure detect imaging-confirmed disease — what pooled sensitivity and specificity (labelled in words) does the meta-analysis give, and what does the Cochrane review conclude about the certainty of that evidence?

Balance of the evidence

MEASUREMENT ACCURACY — NOT ESTABLISHED — Composition: 1 meta-analysis (Herraiz-Adillo 2020: toe-brachial index in 9 studies, 294 patients, 826 limbs) plus 1 Cochrane diagnostic review (Tehan 2024: 18 studies; toe-brachial index investigated in 1,927 participants and 2,550 limbs, toe systolic pressure in 701 participants). Sensitivity/specificity pairs are labelled in words at first occurrence: in the meta-analysis, pooled sensitivity was 81% and specificity 77% (labelled in words) for the toe-brachial index detecting 50% or greater stenosis — more sensitive but less specific than the ankle-brachial index in the same analysis (sensitivity 61% / specificity 92%, labelled in words) — and in the seven studies analysing both directly, the toe index's overall diagnostic accuracy was higher (diagnostic odds ratio 16.4 versus 11.0) (Herraiz-Adillo 2020). The Cochrane review, however, found the studies generally of low methodological quality with poor reporting of recruitment and blinding, rated the certainty of evidence very low for most studies, and concluded that the overall diagnostic performance of toe-brachial index and toe systolic pressure remains uncertain and the evidence base limited (Tehan 2024). MEASUREMENT ACCURACY — NOT ESTABLISHED: a usable pooled estimate exists, but the systematic evidence audit behind it is too weak to treat the toe tests' accuracy as settled.

MeSH: Ankle Brachial Index · Humans · Lower Extremity · Peripheral Arterial Disease · ROC Curve · Blood Pressure · Blood Pressure Determination · Sensitivity and Specificity · Toes

Cards (3)

Card 1 — Meta-analysis: toe-brachial index sensitivity 81% / specificity 77% (labelled in words) — trading specificity for sensitivity against the ankle index (Herraiz-Adillo 2020; 294 patients, 826 limbs)

Study: Systematic review and meta-analysis (toe index: 9 studies, 294 patients)

Population: Systematic review and meta-analysis of diagnostic accuracy studies against vascular imaging: toe-brachial index in 9 studies (294 patients, 826 limbs) and ankle-brachial index in 35 studies (1,318 patients, 5,637 limbs), in a wide spectrum of peripheral arterial disease populations.

Summary: Meta-analysis: toe-brachial index sensitivity 81% / specificity 77% (labelled in words) — trading specificity for sensitivity against the ankle index (Herraiz-Adillo 2020; 294 patients, 826 limbs)

Result: Pooled estimates for detecting 50% or greater stenosis: toe-brachial index sensitivity 81% (95% CI 70–94) and specificity 77% (95% CI 66–90), diagnostic odds ratio 13.1; ankle-brachial index sensitivity 61% (95% CI 55–69) and specificity 92% (95% CI 89–95), diagnostic odds ratio 16.5 (sensitivity and specificity labelled in words at first occurrence on this shelf). In the seven studies jointly analysing both, the toe index showed better overall diagnostic accuracy (diagnostic odds ratio 16.4 versus 11.0), with sensitivity 82% versus 52% and specificity 77% versus 94%. The QUADAS-2 tool identified many studies at high risk of bias, especially in patient selection, and heterogeneity in sensitivity was large.

Watch out: The toe-index pool is small (294 patients) next to the ankle-index pool (1,318 patients), and its confidence intervals are wide — sensitivity could be anywhere from 70% to 94% on this evidence.

Source: Herraiz-Adillo Á, Cavero-Redondo I, Álvarez-Bueno C et al.. The accuracy of toe brachial index and ankle brachial index in the diagnosis of lower limb peripheral arterial disease: A systematic review and meta-analysis. Atherosclerosis. 2020. PMID: 33036766. Registry ID: not stated in the record. MeSH: Ankle Brachial Index · Humans · Lower Extremity · Peripheral Arterial Disease · ROC Curve

Card 2 — Cochrane review of 18 studies: evidence very low certainty, diagnostic performance 'remains uncertain' (Tehan 2024; TBI in 1,927 participants)

Study: Cochrane diagnostic test accuracy review (18 studies)

Population: Cochrane diagnostic test accuracy review: 18 studies (13 toe-brachial index only, 1 toe systolic pressure only, 4 both) against imaging reference standards (13 used colour duplex ultrasound; others CT angiography, multi-detector CT, angiography, or combinations). Toe-brachial index was investigated in 1,927 participants and 2,550 limbs; toe systolic pressure in 701 participants (701 limbs).

Summary: Cochrane review of 18 studies: evidence very low certainty, diagnostic performance 'remains uncertain' (Tehan 2024; TBI in 1,927 participants)

Result: Studies were generally of low methodological quality, with poor reporting of consecutive or random sampling, of blinding between index and reference tests, and of timing between tests; the certainty of evidence by GRADE was very low for most studies. The review concludes that whilst both tests are used extensively clinically, the overall diagnostic performance of toe-brachial index and toe systolic pressure remains uncertain, the evidence base to support their use is limited, and future research with robust methods is warranted. The review prints no pooled sensitivity/specificity pair, and none is printed here.

Watch out: Very-low-certainty evidence is a statement about the studies' methods and reporting, not proof the test performs badly — it means the pooled numbers on the card above should not be treated as settled.

Source: Tehan PE, Mills J, Leask S et al.. Toe-brachial index and toe systolic blood pressure for the diagnosis of peripheral arterial disease. The Cochrane database of systematic reviews. 2024. PMID: 39474992. Registry ID: not stated in the record. MeSH: Humans · Ankle Brachial Index · Blood Pressure · Blood Pressure Determination · Peripheral Arterial Disease · Sensitivity and Specificity · Toes

Card 3 — Synthesis — the toe test probably catches disease the ankle test misses, on evidence too weak to price exactly

Study: Synthesis

Population: Synthesis of the two records carded on this shelf; no additional source.

Summary: Synthesis — the toe test probably catches disease the ankle test misses, on evidence too weak to price exactly

Result: The meta-analysis gives the toe-brachial index a sensitivity of 81% with specificity 77% (labelled in words), better sensitivity than the ankle index at the cost of specificity — the profile that matters where ankle arteries are calcified. The Cochrane audit of a larger study set (1,927 participants) rates that evidence very low certainty and the performance uncertain. Both can be true: the point estimate is the best available, and it is not established.

Watch out: Boundary: ankle-brachial index accuracy itself is owned by live shelf #7811 (its question and headlines were read — it covers the ankle index including oscillometric measurement, not the toe index); ankle-brachial index prediction of cardiovascular events is live #6292 and its population distribution live #7261. This shelf owns only the toe tests.

Source: Synthesis of the carded records above (PMIDs 33036766, 39474992). Registry ID: not stated in the records.