SourceMed · Shelf #9816 in the ask interface

Endoscopic ultrasound fine-needle biopsy versus fine-needle aspiration for pancreatic masses (2 meta-analyses of randomised trials; 921 cases in the earlier pool): the 2017 pool found no accuracy difference; the 2022 pool found biopsy accuracy superior (pooled odds ratio 1.87)

Shelf #9816 · Liver & gut

SPLIT

Stamped: 2026-11-28.

Evidence published: 2017–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with pancreatic masses undergoing endoscopic ultrasound-guided sampling, does fine-needle biopsy (FNB) diagnose pancreatic cancer more accurately than fine-needle aspiration (FNA), and does it need fewer needle passes?

Balance of the evidence

SPLIT — Composition: 2 meta-analyses of randomised controlled trials reaching different conclusions on the primary accuracy outcome; accuracy shelves are always. Wang 2017 (8 randomised trials, 921 cases): diagnostic accuracy did not differ significantly between biopsy and aspiration; specimen adequacy was higher with biopsy, fewer needle passes were needed for sufficient tissue with biopsy, and adverse events and technical success did not differ. Hassan 2022 (9 randomised trials, 2011–2021 literature): five trials found no significant accuracy difference and four did; the pooled estimate favoured biopsy, with a pooled odds ratio for diagnostic accuracy of 1.87 (95% CI 1.33 to 2.63). The two pools overlap in trials; the documented total is stated as the earlier pool's 921 cases (the later record does not state its combined case total, and none is printed). No live shelf and no pack on disk asks this question: pack #9410 compares biopsy needle designs and suction techniques within fine-needle biopsy practice only — its question and cards were read, and aspiration is not its comparator. SPLIT: the syntheses agree that biopsy yields more adequate tissue in fewer passes, and disagree on whether that converts into higher diagnostic accuracy.

MeSH: Endoscopic Ultrasound-Guided Fine Needle Aspiration · Humans · Pancreatic Neoplasms · Randomized Controlled Trials as Topic

Cards (3)

Card 1 — Wang 2017 (8 randomised trials, 921 cases): diagnostic accuracy did not differ between biopsy and aspiration; adequacy higher and passes fewer with biopsy

Study: Meta-analysis of randomised trials (8 trials; 921 cases)

Population: Meta-analysis of 8 randomised controlled trials comprising 921 cases, comparing endoscopic-ultrasound-guided fine-needle aspiration with fine-needle biopsy for the diagnosis of pancreatic masses (literature to 2016).

Summary: Wang 2017 (8 randomised trials, 921 cases): diagnostic accuracy did not differ between biopsy and aspiration; adequacy higher and passes fewer with biopsy

Result: Diagnostic accuracy was not significantly different between the aspiration and biopsy groups (the treatment made no difference to diagnostic accuracy). Specimen adequacy was higher in the biopsy group than in the aspiration group, and the number of needle passes needed to obtain sufficient tissue was lower in the biopsy group. Rates of adverse events and technical success did not differ significantly between the two groups, although the forest plot showed a trend toward lower technical success and a trend toward higher diagnostic accuracy in the biopsy group. The authors concluded that biopsy is comparable to aspiration for diagnostic accuracy, adverse events and technical success, and gives higher specimen adequacy despite fewer needle passes.

Watch out: This pool predates the modern Franseen and fork-tip biopsy needles evaluated in pack #9410; its biopsy arm mixes older core-needle designs, so its accuracy tie may describe superseded equipment rather than current practice.

Source: Wang J, Zhao S, Chen Y, Jia R. Endoscopic ultrasound guided fine needle aspiration versus endoscopic ultrasound guided fine needle biopsy in sampling pancreatic masses: A meta-analysis. Medicine (Baltimore). 2017. PMID: 28700483. Registry ID: not stated in the record. MeSH: Endoscopic Ultrasound-Guided Fine Needle Aspiration · Humans · Pancreatic Neoplasms · Randomized Controlled Trials as Topic

Card 2 — Hassan 2022 (9 randomised trials): pooled accuracy favoured biopsy (odds ratio 1.87, 95% CI 1.33 to 2.63) — with five of nine trials individually null

Study: Systematic review and meta-analysis (9 randomised trials; total N not stated in the record)

Population: Systematic review and meta-analysis of 9 randomised controlled trials published 2011–2021 (selected from 5,802 identified articles) comparing endoscopic-ultrasound-guided aspiration with biopsy needles for the diagnosis of pancreatic cancer; the record does not state the combined number of cases, and none is printed here.

Summary: Hassan 2022 (9 randomised trials): pooled accuracy favoured biopsy (odds ratio 1.87, 95% CI 1.33 to 2.63) — with five of nine trials individually null

Result: Five of the nine studies found no statistically significant difference between aspiration and biopsy, whereas the other four did. The meta-analysis found biopsy accuracy superior to aspiration for the diagnosis of pancreatic cancer, with a pooled odds ratio of 1.87 (95% CI 1.33 to 2.63). The authors concluded that, compared with aspiration, biopsy seems to improve diagnostic accuracy when applied to suspicious pancreatic lesions.

Watch out: A pooled odds ratio of 1.87 built from a majority of individually null trials is sensitive to which trials and which accuracy definitions are pooled; the record reports the outcome as diagnostic accuracy or probability of positivity, sensitivity, specificity and predictive value across studies — sensitivity and specificity labelled in words — not a single uniform endpoint.

Source: Hassan GM, Laporte L, Paquin SC, Menard C. Endoscopic Ultrasound Guided Fine Needle Aspiration versus Endoscopic Ultrasound Guided Fine Needle Biopsy for Pancreatic Cancer Diagnosis: A Systematic Review and Meta-Analysis. Diagnostics (Basel). 2022. PMID: 36552957. Registry ID: not stated in the record. MeSH: the record carries no MeSH list (stated plainly; this pack's MeSH comes from the Wang record).

Card 3 — Synthesis — adequacy and efficiency agree; accuracy splits by era of needle

Study: Synthesis

Population: Synthesis of the two meta-analyses carded on this shelf; no additional source.

Summary: Synthesis — adequacy and efficiency agree; accuracy splits by era of needle

Result: The consistent findings are practical: biopsy specimens are more often adequate and are obtained in fewer passes. The contested finding is accuracy: no difference in the pre-2017 pool, a pooled advantage for biopsy in the 2011–2021 pool. Because the later pool adds trials of newer needle designs, the split is plausibly an equipment-era effect — but on the records carded here it remains a disagreement between syntheses, and the stamp records it as one. This is an accuracy shelf and is Tier C on that basis.

Watch out: The two pools overlap in randomised trials; documented N is stated as 921 cases from the earlier pool because the later record does not state its total. Whether biopsy replaces aspiration also depends on on-site evaluation practice, which is the separate question carded at #9821.