SourceMed · Shelf #9824 in the ask interface
Amyloid PET for Alzheimer's pathology (documented N = 5,967 in the largest pooled analysis): against autopsy plaque pathology, sensitivity 92% / specificity 100% for florbetapir and sensitivity 91.9% / specificity 87.5% for flutemetamol — but pooled specificity for separating Alzheimer's dementia from MCI was only 0.49
Shelf #9824 · Brain, stroke & mind
SPLIT — by what the scan is asked to separate: against autopsy neuritic-plaque pathology the approved tracers are accurate (florbetapir sensitivity 92% / specificity 100%; flutemetamol sensitivity 91.9% / specificity 87.5% on the original CERAD standard), while in pooled clinical studies specificity falls to 0.49 when the task is separating Alzheimer's dementia from MCI, because amyloid-positive MCI is counted as error; this is an accuracy shelf and is Tier C
Stamped: 2026-11-28.
Evidence published: 2012–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does amyloid PET (florbetapir, flutemetamol, florbetaben and 11C-PiB) detect Alzheimer's amyloid pathology — against autopsy neuropathology, and in pooled clinical diagnosis studies?
Balance of the evidence
SPLIT — by reference standard and comparison. Composition: two prospective imaging-to-autopsy cohorts (florbetapir, 59 participants with autopsy within 2 years; flutemetamol, 106 end-of-life patients), one 2016 systematic review and meta-analysis of the three 18F tracers (9 studies), and one 2023 Bayesian meta-analysis (48 studies, 5,967 patients). Against autopsy, florbetapir PET read visually gave sensitivity 92% (36 of 39) and specificity 100% (20 of 20) for moderate-to-frequent neuritic plaques (sensitivity and specificity labelled in words throughout this shelf), and flutemetamol gave sensitivity 91.9% / specificity 87.5% against original CERAD criteria and sensitivity 85.7% / specificity 100% against the 2012 NIA-AA criteria. In the 2023 pooling of clinical-diagnosis studies, amyloid PET diagnosed Alzheimer's disease with pooled sensitivity 0.90 / specificity 0.80 overall, but specificity was 0.49 for separating Alzheimer's dementia from MCI, and prediction of MCI conversion gave sensitivity 0.84 / specificity 0.62. SPLIT: the scan measures plaque pathology accurately; it does not, by itself, separate clinical syndromes that share that pathology.
MeSH: Aged · Aged, 80 and over · Aniline Compounds · Brain · Dementia · Ethylene Glycols · Female · Humans · Male · Middle Aged · Neurites · Neurofibrillary Tangles · Plaque, Amyloid · Prospective Studies · Radionuclide Imaging · Sensitivity and Specificity · Alzheimer Disease · Benzothiazoles · Case-Control Studies · Positron-Emission Tomography · Radiopharmaceuticals · Reproducibility of Results · Stilbenes · Bayes Theorem · Amyloid beta-Peptides · Cognitive Dysfunction
Cards (5)
Card 1 — Florbetapir imaging-to-autopsy cohort (Clark 2012): sensitivity 92% / specificity 100% for moderate-to-frequent neuritic plaques in 59 participants
Study: Prospective imaging-to-autopsy accuracy cohort
Population: Prospective cohort at 22 US centres: participants with life expectancy under 6 months at enrolment (cognitive status from normal to advanced dementia, aged 47-103 years) who had florbetapir (18F) PET and autopsy within 2 years of imaging (59 participants; 46 within 1 year); five nuclear medicine physicians' majority read classified each scan amyloid positive or negative, against CERAD-classed autopsy plaque pathology.
Summary: Florbetapir imaging-to-autopsy cohort (Clark 2012): sensitivity 92% / specificity 100% for moderate-to-frequent neuritic plaques in 59 participants
Result: For autopsy within 2 years: sensitivity 92% (36 of 39; 95% CI 78-98) and specificity 100% (20 of 20; 95% CI 80-100) for moderate-to-frequent plaques (sensitivity and specificity labelled in words at first occurrence here and throughout this shelf). For autopsy within 1 year: sensitivity 96% (27 of 28) and specificity 100% (18 of 18). Semiquantitative florbetapir uptake correlated with post-mortem amyloid burden (Spearman rho 0.76 within 2 years; 0.79 within 12 months; both p<0.0001).
Watch out: End-of-life volunteers are not memory-clinic patients: plaque prevalence was high (39 of 59 positive), which flatters sensitivity, and the specificity estimate rests on 20 plaque-negative brains. Industry-funded (Avid Radiopharmaceuticals, per the record).
Source: Clark CM et al. The Lancet Neurology. 2012. PMID: 22749065. Registry ID: NCT00857415 and NCT01447719 (ClinicalTrials.gov, as printed in the record). MeSH: Aged · Aged, 80 and over · Aniline Compounds · Brain · Dementia · Ethylene Glycols · Female · Humans · Male · Middle Aged · Neurites · Neurofibrillary Tangles · Plaque, Amyloid · Prospective Studies · Radionuclide Imaging · Sensitivity and Specificity
Card 2 — Flutemetamol imaging-to-autopsy study (Salloway 2017): sensitivity 91.9% / specificity 87.5% against original CERAD neuritic plaques in 106 end-of-life patients
Study: Imaging-to-autopsy accuracy study
Population: 106 end-of-life patients who underwent [18F]flutemetamol imaging and post-mortem brain examination for amyloid plaque load; blinded PET interpretations by five independent electronically trained readers (majority read) compared with three pathology standards of truth: original CERAD, modified CERAD, and the amyloid component of the 2012 NIA-AA neuropathologic criteria.
Summary: Flutemetamol imaging-to-autopsy study (Salloway 2017): sensitivity 91.9% / specificity 87.5% against original CERAD neuritic plaques in 106 end-of-life patients
Result: Majority-read sensitivity and specificity were, respectively, 91.9% and 87.5% against original CERAD, 90.8% and 90.0% against modified CERAD, and 85.7% and 100% against the 2012 NIA-AA criteria (sensitivity and specificity labelled in words throughout this shelf). The authors note CERAD-based standards can yield some false positives because diffuse plaques count toward CERAD plaque scores but are handled differently under NIA-AA.
Watch out: The same scans score differently against different pathology standards (specificity 87.5% versus 100%), so a single accuracy pair for flutemetamol is an artefact of the chosen standard. The record carries no MeSH list, so none is printed for this card.
Source: Salloway S et al. Alzheimer's & Dementia (Amsterdam). 2017. PMID: 28795133. Registry ID: not stated in the record. MeSH: none listed in the record.
Card 3 — Meta-analysis of the three 18F tracers (Morris 2016): pooled sensitivity and specificity generally high for all tracers — and higher against healthy controls than against other patients
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: Systematic review and meta-analysis of diagnostic accuracy studies (1990-2014) of florbetaben, florbetapir and flutemetamol in Alzheimer's disease: 9 eligible studies, each small; quality assessed with QUADAS.
Summary: Meta-analysis of the three 18F tracers (Morris 2016): pooled sensitivity and specificity generally high for all tracers — and higher against healthy controls than against other patients
Result: The record's abstract reports no single pooled sensitivity/specificity pair: it states pooled sensitivity and specificity were in general high for all three tracers, with no marked differences between tracers and comparable performance for visual and quantitative analysis, and that specificity was higher when patients with Alzheimer's disease were compared with healthy controls than in other comparisons. Likelihood ratios indicated a positive scan makes Alzheimer's disease much more likely and a negative scan much less likely.
Watch out: Nine small studies, many of them case-control comparisons against healthy volunteers — the design known to inflate accuracy. The absence of a pooled pair in the record is stated plainly rather than filled from the full text.
Source: Morris E et al. European Journal of Nuclear Medicine and Molecular Imaging. 2016. PMID: 26613792. Registry ID: not stated in the record. MeSH: Aged · Alzheimer Disease · Aniline Compounds · Benzothiazoles · Case-Control Studies · Ethylene Glycols · Female · Humans · Male · Middle Aged · Positron-Emission Tomography · Radiopharmaceuticals · Reproducibility of Results · Stilbenes
Card 4 — Bayesian meta-analysis 2023 (Ruan & Sun): 48 studies, 5,967 patients — pooled sensitivity 0.90 / specificity 0.80 for Alzheimer's diagnosis, but specificity 0.49 against MCI
Study: Systematic review and Bayesian meta-analysis
Population: Bayesian random-effects meta-analysis of amyloid-beta PET diagnostic studies across centres: 48 studies including 5,967 patients, covering Alzheimer's disease diagnosis and prediction of conversion from mild cognitive impairment (MCI) to Alzheimer's dementia, by population, tracer and read method.
Summary: Bayesian meta-analysis 2023 (Ruan & Sun): 48 studies, 5,967 patients — pooled sensitivity 0.90 / specificity 0.80 for Alzheimer's diagnosis, but specificity 0.49 against MCI
Result: Overall pooled sensitivity 0.90, specificity 0.80, diagnostic odds ratio 35.68 and AUC 0.91 for diagnosing Alzheimer's disease (sensitivity and specificity labelled in words throughout this shelf). For differentiating Alzheimer's disease from normal controls, sensitivity was 0.91 and specificity 0.81; for determining Alzheimer's disease from MCI, specificity was 0.49. For predicting MCI conversion to Alzheimer's dementia, pooled sensitivity was 0.84 and specificity 0.62. Differences between visual and quantitative reads and between 11C-PiB and 18F-florbetapir were not significant.
Watch out: The reference standard in most pooled studies is clinical diagnosis, not autopsy — so the 0.49 specificity against MCI partly measures how much amyloid-positive MCI exists, not scanner error. Pools overlap with the autopsy cohorts carded above and are not added to them.
Source: Ruan D, Sun L. Brain and Behavior. 2023. PMID: 36573329. Registry ID: not stated in the record. MeSH: Humans · Alzheimer Disease · Bayes Theorem · Amyloid beta-Peptides · Cognitive Dysfunction · Sensitivity and Specificity · Positron-Emission Tomography
Card 5 — Synthesis: amyloid PET is an accurate plaque detector and a weak syndrome separator — both statements are in the same evidence
Study: Synthesis
Population: Across the reports carded above (largest documented pool: 5,967 patients in the 2023 meta-analysis; autopsy cohorts of 59 and 106 reported separately, not added).
Summary: Synthesis: amyloid PET is an accurate plaque detector and a weak syndrome separator — both statements are in the same evidence
Result: Read against pathology, a negative scan reliably indicates no or sparse plaques and a positive scan indicates moderate-to-frequent plaques. Read against clinical categories, the same positivity appears in MCI and in cognitively normal older people, which is why specificity collapses when the comparison group is MCI (0.49) rather than healthy controls (0.81). The stamp is SPLIT because the verdict reverses with the question asked of the test.
Watch out: This shelf covers detection of amyloid pathology, not whether amyloid-lowering treatment helps patients (a separate live shelf covers anti-amyloid antibodies) and not blood biomarkers such as plasma p-tau217 (also a separate live shelf).
Source: Synthesis of the reports carded above; no additional source.