Preventive stenting of non-flow-limiting vulnerable coronary plaques (documented N = 1,788 in 2 randomised trials): PREVENT cut target-vessel events to 0.4% versus 3.4% at 2 years, while the PROSPECT ABSORB pilot found no difference in target lesion failure (4.3% versus 4.5%)

Shelf #9845 · Heart, vessels, blood pressure & clotting

SPLIT (by trial)

Stamped: 2026-11-28.

Evidence published: 2020–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with non-flow-limiting, imaging-defined vulnerable coronary plaques, does preventive percutaneous coronary intervention plus medical therapy, compared with medical therapy alone, reduce cardiac events arising from those plaques?

Balance of the evidence

SPLIT (by trial) — Composition: 2 independent randomised trials, documented N = 1,788 (1,606 + 182). PREVENT (1,606 patients, everolimus-eluting stent era devices plus optimal medical therapy versus medical therapy alone) found the primary composite — cardiac death, target-vessel myocardial infarction, ischaemia-driven target-vessel revascularisation, or hospitalisation for unstable or progressive angina — in 0.4% versus 3.4% at 2 years (absolute difference −3.0 percentage points; p = 0.0003). The earlier PROSPECT ABSORB pilot (182 patients) was powered for a lumen-area endpoint, which it met (follow-up minimum lumen area 6.9 versus 3.0 mm²), but its clinical safety endpoint, target lesion failure at 24 months, occurred in 4.3% versus 4.5% (the treatment made no difference; p = 0.96) using a since-discontinued bioresorbable scaffold. One large positive trial and one small neutral pilot with different devices and different plaque definitions — the honest stamp is a split. SPLIT (by trial): preventive intervention on vulnerable plaques reduced events in the one large trial designed to test clinical outcomes; the pilot trial showed lumen enlargement without a clinical difference.

MeSH: Humans · Male · Female · Percutaneous Coronary Intervention · Middle Aged · Aged · Coronary Artery Disease · Plaque, Atherosclerotic · Treatment Outcome · New Zealand · Republic of Korea · Taiwan · Japan · Myocardial Infarction · Acute Coronary Syndrome · Absorbable Implants · Blood Vessel Prosthesis Implantation · Coronary Stenosis · Dual Anti-Platelet Therapy · Pilot Projects · Stents · Ultrasonography, Interventional

Cards (3)

Card 1 — PREVENT (1,606 patients): preventive PCI cut the primary composite to 0.4% versus 3.4% on medical therapy alone at 2 years (Park 2024)

Study: Randomised controlled trial (PREVENT, 1,606 patients)

Population: 1,606 patients aged 18 years or older with non-flow-limiting (fractional flow reserve > 0.80) vulnerable coronary plaques identified by intracoronary imaging at 15 hospitals in four countries, randomly assigned to percutaneous coronary intervention plus optimal medical therapy (n = 803) or optimal medical therapy alone (n = 803); 2-year follow-up completed in 1,556 (97%).

Summary: PREVENT (1,606 patients): preventive PCI cut the primary composite to 0.4% versus 3.4% on medical therapy alone at 2 years (Park 2024)

Result: At 2 years the primary outcome (death from cardiac causes, target-vessel myocardial infarction, ischaemia-driven target-vessel revascularisation, or hospitalisation for unstable or progressive angina) occurred in three patients (0.4%) in the intervention group and 27 (3.4%) in the medical-therapy group (absolute difference −3.0 percentage points, 95% CI −4.4 to −1.8; p = 0.0003), with the effect directionally consistent for each component. Death occurred in four patients (0.5%) versus ten (1.3%) and myocardial infarction in nine (1.1%) versus 13 (1.7%).

Watch out: Open-label trial with very low absolute event rates (3 versus 27 primary events): the relative effect is large but rests on few events, and hospitalisation for angina — a decision-sensitive component — is part of the composite. Plaques were imaging-selected (at least two high-risk features).

Source: Park SJ, Ahn JM, Kang DY et al.. Preventive percutaneous coronary intervention versus optimal medical therapy alone for the treatment of vulnerable atherosclerotic coronary plaques (PREVENT): a multicentre, open-label, randomised controlled trial. Lancet (London, England). 2024. PMID: 38604213. Registry ID: NCT02316886. MeSH: Humans · Male · Female · Percutaneous Coronary Intervention · Middle Aged · Aged · Coronary Artery Disease · Plaque, Atherosclerotic · Treatment Outcome · New Zealand · Republic of Korea · Taiwan · Japan · Myocardial Infarction · Acute Coronary Syndrome

Card 2 — PROSPECT ABSORB pilot (182 patients): scaffold treatment enlarged the lumen (6.9 versus 3.0 mm² at 25 months) but target lesion failure did not differ (4.3% versus 4.5%) (Stone 2020)

Study: Randomised pilot trial (PROSPECT ABSORB, 182 patients)

Population: 182 patients presenting with myocardial infarction, after successful treatment of all flow-limiting lesions, with an angiographically nonobstructive stenosis not intended for PCI but with intravascular-ultrasound plaque burden of at least 65%, randomly assigned to a bioresorbable vascular scaffold plus guideline-directed medical therapy (n = 93) or medical therapy alone (n = 89) at 15 centres; median clinical follow-up 4.1 years.

Summary: PROSPECT ABSORB pilot (182 patients): scaffold treatment enlarged the lumen (6.9 versus 3.0 mm² at 25 months) but target lesion failure did not differ (4.3% versus 4.5%) (Stone 2020)

Result: The powered effectiveness endpoint favoured the scaffold: follow-up minimum lumen area 6.9 ± 2.6 mm² versus 3.0 ± 1.0 mm² (least-squares mean difference 3.9 mm², 95% CI 3.3 to 4.5; p < 0.0001). The nonpowered safety endpoint, target lesion failure at 24 months, occurred in 4.3% versus 4.5% (the treatment made no difference; p = 0.96). The nonpowered clinical endpoint of randomised lesion-related major adverse cardiac events occurred in 4.3% versus 10.7% (odds ratio 0.38, 95% CI 0.11 to 1.28; p = 0.12).

Watch out: Pilot trial powered for an imaging endpoint, not clinical events; the tested product is named as the publication gives it — the Absorb bioresorbable vascular scaffold (Abbott Vascular, per the trial report) — a scaffold that was later withdrawn from the market, so its results do not transfer directly to current drug-eluting stents.

Source: Stone GW, Maehara A, Ali ZA et al.. Percutaneous Coronary Intervention for Vulnerable Coronary Atherosclerotic Plaque. Journal of the American College of Cardiology. 2020. PMID: 33069847. Registry ID: NCT02171065. MeSH: Absorbable Implants · Aged · Blood Vessel Prosthesis Implantation · Coronary Artery Disease · Coronary Stenosis · Dual Anti-Platelet Therapy · Female · Humans · Male · Middle Aged · Percutaneous Coronary Intervention · Pilot Projects · Plaque, Atherosclerotic · Stents · Ultrasonography, Interventional

Card 3 — Synthesis: two trials, two designs — the large stent trial positive on events, the small scaffold pilot neutral on its clinical endpoint

Study: Synthesis

Population: 1,788 randomised patients across the two trials (1,606 + 182); populations differ (PREVENT: stable and acute presentations with imaging-defined vulnerable plaques; PROSPECT ABSORB: post-myocardial-infarction patients with high-plaque-burden nonculprit lesions).

Summary: Synthesis: two trials, two designs — the large stent trial positive on events, the small scaffold pilot neutral on its clinical endpoint

Result: Both trials show preventive intervention is technically feasible and enlarges the treated lumen. Only PREVENT was designed and powered for clinical events, and it found fewer target-vessel events with intervention (0.4% versus 3.4% at 2 years). Whether the PREVENT result generalises beyond its imaging selection criteria and very low event rates is untested by any second outcomes trial.

Watch out: Boundary: live shelf #1177 owns imaging guidance of stent implantation for flow-limiting lesions (ULTIMATE, OCTOBER, ILUMIEN IV); this shelf owns the different question of intervening on plaques that are not flow-limiting at all.

Source: Synthesis of the carded records above (PMIDs 38604213, 33069847). Registry IDs: NCT02316886, NCT02171065.