SourceMed · Shelf #9846 in the ask interface

Artificial-intelligence-guided ablation added to pulmonary vein isolation in persistent atrial fibrillation (TAILORED-AF, documented N = 370): freedom from atrial fibrillation in 88% versus 70% at 12 months

Shelf #9846 · Heart, vessels, blood pressure & clotting

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with drug-refractory persistent atrial fibrillation, does ablation guided by an artificial-intelligence algorithm targeting spatio-temporal electrogram dispersion, added to pulmonary vein isolation, improve freedom from atrial fibrillation at 12 months compared with pulmonary vein isolation alone?

Balance of the evidence

POSSIBLE (benefit) — Composition: 1 randomised trial (TAILORED-AF, 370 patients) with a prespecified sex analysis of the same trial; patients counted once. Freedom from documented atrial fibrillation at 12 months after a single procedure was achieved in 88% of the tailored arm versus 70% of the isolation-only arm (log-rank P < 0.0001 for superiority) — an absolute difference of 18 percentage points — but freedom from any atrial arrhythmia did not differ significantly between arms, and procedure and ablation times were twice as long in the tailored arm. The tested system is named as the trial's published descriptions give it: the Volta AF-Xplorer artificial-intelligence system (Volta Medical). One trial, with the broader arrhythmia endpoint neutral — held at POSSIBLE. POSSIBLE (benefit): AI-guided dispersion ablation added to isolation improved freedom from atrial fibrillation at 1 year in one randomised trial of persistent atrial fibrillation, at the cost of doubled procedure time and with no gain on the any-arrhythmia endpoint.

MeSH: Humans · Atrial Fibrillation · Artificial Intelligence · Female · Male · Middle Aged · Aged · Catheter Ablation · Double-Blind Method · Treatment Outcome · Anti-Arrhythmia Agents · Pulmonary Veins · Precision Medicine · Algorithms · Sex Factors · Action Potentials · Recurrence · Time Factors · Heart Rate

Cards (3)

Card 1 — TAILORED-AF (370 patients): freedom from atrial fibrillation at 12 months in 88% with AI-guided tailored ablation versus 70% with isolation alone (Deisenhofer 2025)

Study: Randomised controlled trial (TAILORED-AF, 370 patients)

Population: 370 patients with drug-refractory persistent atrial fibrillation randomly assigned to a tailored ablation procedure targeting areas of spatio-temporal dispersion detected by an artificial-intelligence algorithm, in addition to pulmonary vein isolation (n = 187, 23% women), or to a conventional isolation-only procedure (n = 183, 19% women); multicentre, double-blind, superiority design.

Summary: TAILORED-AF (370 patients): freedom from atrial fibrillation at 12 months in 88% with AI-guided tailored ablation versus 70% with isolation alone (Deisenhofer 2025)

Result: The primary efficacy endpoint — freedom from documented atrial fibrillation, with or without antiarrhythmic drugs, at 12 months after a single ablation procedure — was achieved in 88% of the tailored arm compared with 70% of the anatomical (isolation-only) arm (log-rank P < 0.0001 for superiority), an absolute difference of 18 percentage points. No significant difference between arms was observed for freedom from any atrial arrhythmia after one ablation, and the composite safety endpoint (death, cerebrovascular events, or treatment-related serious adverse events) did not differ between arms; procedure and ablation times were twice as long in the tailored arm.

Watch out: Single trial, industry-developed algorithm (Volta Medical); the primary endpoint counts atrial fibrillation only — organised atrial tachycardias after tailored ablation were common enough that the any-arrhythmia endpoint showed no significant difference, and the authors note subsequent tachycardias may need their own ablation.

Source: Deisenhofer I, Albenque JP, Busch S et al.. Artificial intelligence for individualized treatment of persistent atrial fibrillation: a randomized controlled trial. Nature medicine. 2025. PMID: 39953289. Registry ID: NCT04702451. MeSH: Humans · Atrial Fibrillation · Artificial Intelligence · Female · Male · Middle Aged · Aged · Catheter Ablation · Double-Blind Method · Treatment Outcome · Anti-Arrhythmia Agents · Pulmonary Veins · Precision Medicine · Algorithms

Card 2 — TAILORED-AF sex analysis (same 370 patients; 77 women): in women, freedom from atrial fibrillation was 76% with tailored ablation versus 50% with isolation alone (Deisenhofer 2025)

Study: Prespecified subgroup analysis of a randomised controlled trial (same 370 patients)

Population: Prespecified analysis of the same TAILORED-AF trial by sex: 77 women (21% of 370 patients; mean age 70.4 years versus 64.5 years in men) — not additional patients.

Summary: TAILORED-AF sex analysis (same 370 patients; 77 women): in women, freedom from atrial fibrillation was 76% with tailored ablation versus 50% with isolation alone (Deisenhofer 2025)

Result: In women, single-procedure freedom from atrial fibrillation was 76% with the tailored procedure versus 50% with isolation alone (log-rank P < 0.001), and freedom from any atrial arrhythmia was 56% versus 38% (log-rank P < 0.05). In the isolation-only group, women fared worse than men (freedom from atrial fibrillation 50% versus 70%; log-rank P < 0.001); after tailored ablation, outcomes in women and men did not differ significantly (76% versus 91%; log-rank P = 0.07). Spatio-temporal dispersion extent was similar between the sexes, while left atrial low-voltage surface area was larger in women (P < 0.01).

Watch out: Subgroup analysis of one trial with 77 women — hypothesis-supporting, not independent confirmation; the parent trial remains the evidence base.

Source: Deisenhofer I, Seitz J, Nguyen-Tu MS et al.. Women with persistent atrial fibrillation need more than pulmonary vein isolation: personalised extra-pulmonary vein ablation strategy vs. pulmonary vein isolation alone in the TAILORED-AF trial. Europace. 2025. PMID: 41311304. Registry ID: NCT04702451. MeSH: Humans · Atrial Fibrillation · Female · Pulmonary Veins · Catheter Ablation · Middle Aged · Male · Aged · Sex Factors · Treatment Outcome · Action Potentials · Artificial Intelligence · Recurrence · Time Factors · Heart Rate

Card 3 — Synthesis: a personalised, map-driven add-on strategy wins on the atrial-fibrillation endpoint in its single trial

Study: Synthesis

Population: 370 randomised patients in the single carded trial (the sex analysis reports the same patients).

Summary: Synthesis: a personalised, map-driven add-on strategy wins on the atrial-fibrillation endpoint in its single trial

Result: TAILORED-AF is the second individualised add-on strategy to beat isolation alone in a randomised trial of persistent atrial fibrillation (the other is voltage-guided ablation, shelf #9844), after empiric add-on strategies failed (live shelf #3318). Its win is confined to freedom from atrial fibrillation; any-arrhythmia freedom, safety and procedure burden (twice the time) temper it.

Watch out: No replication trial is carded; the algorithm is a specific commercial product (Volta Medical's AI system, as named in the trial reports) and results may not transfer to other dispersion-mapping approaches.

Source: Synthesis of the carded records above (PMIDs 39953289, 41311304). Registry ID: NCT04702451.