Remote dielectric sensing (ReDS)-guided decongestion in acute heart failure (documented N = 208 in 2 randomised trials): a positive proof-of-concept trial (events in 2% versus 20% at 1 month) and a pilot in which guided care decongested more but readmissions did not differ (1.7% versus 4.2%)
Shelf #9847 · Heart, vessels, blood pressure & clotting
SPLIT (by trial)
Stamped: 2026-11-28.
Evidence published: 2021–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients hospitalised with acute decompensated heart failure, does management guided by remote dielectric sensing of lung fluid, compared with routine clinical assessment, improve decongestion and reduce early post-discharge heart-failure events?
Balance of the evidence
SPLIT (by trial) — Composition: 2 small randomised trials, documented N = 208 (100 + 108). In ReDS-SAFE HF (100 patients), requiring a ReDS value of 35% or less before discharge cut the 1-month composite of unplanned heart-failure visits, heart-failure rehospitalisation or death to 1 patient (2%) versus 10 (20%) on routine care (hazard ratio 0.094, 95% CI 0.012 to 0.731) — an absolute difference of 18 percentage points, mainly fewer readmissions, at the cost of a median stay 2 days longer (8 versus 6 days; P = 0.203). In the earlier single-centre pilot (108 patients), ReDS-guided extra diuresis produced more decongestion (additional weight loss averaging 5.6 pounds in those treated) but 30-day heart-failure readmission did not differ (1.7% versus 4.2%; p = 0.44) — the treatment made no difference to readmission in that sample; patients discharged with residual congestion (ReDS at least 39%) were readmitted more often (11.8% versus 1.4%; p = 0.03). One very positive tiny trial and one neutral pilot — SPLIT. The tested system is named as the publications give it: the ReDS system (Sensible Medical Innovations). SPLIT (by trial): ReDS-guided decongestion shows a large early-event reduction in one 100-patient proof-of-concept trial and no readmission difference in the 108-patient pilot.
MeSH: Humans · Male · Middle Aged · Aged · Aged, 80 and over · Female · Heart Failure · Patient Discharge · Stroke Volume · Single-Blind Method · Aftercare · Ventricular Function, Left · Lung · Patient Readmission · Pilot Projects · Prospective Studies
Cards (3)
Card 1 — ReDS-SAFE HF (100 patients): events at 1 month in 2% with ReDS-guided discharge criteria versus 20% with routine care (hazard ratio 0.094) (Alvarez-Garcia 2024)
Study: Randomised controlled trial (ReDS-SAFE HF, 100 patients)
Population: 100 patients with acutely decompensated heart failure (mean age 67 ± 14 years, 74% men, mean ejection fraction 37% ± 16%) randomly assigned to routine care, with discharge by current clinical practice, or to an ReDS-guided decongestion strategy requiring a ReDS value of 35% or less for discharge; measurements daily and at a 7-day follow-up visit, blinded in the routine-care arm.
Summary: ReDS-SAFE HF (100 patients): events at 1 month in 2% with ReDS-guided discharge criteria versus 20% with routine care (hazard ratio 0.094) (Alvarez-Garcia 2024)
Result: The primary outcome (composite of unplanned visits for heart failure, heart-failure rehospitalisation, or death at 1 month after discharge) occurred in 1 patient (2%) in the ReDS-guided group and 10 (20%) in the routine-care group (log-rank P = 0.005; hazard ratio 0.094, 95% CI 0.012 to 0.731; P = 0.003), an absolute difference of 18 percentage points, mainly from fewer heart-failure readmissions; the reported number needed to treat was 6 (95% CI 3 to 17). Median length of stay was 2 days longer in the ReDS-guided group (8 versus 6 days; P = 0.203).
Watch out: Proof-of-concept trial with 11 primary events in total: a hazard ratio of 0.094 from 1 versus 10 events is fragile, and the guided strategy kept patients in hospital a median 2 days longer. Single-blind, investigator-initiated.
Source: Alvarez-Garcia J, Lala A, Rivas-Lasarte M et al.. Remote Dielectric Sensing Before and After Discharge in Patients With ADHF: The ReDS-SAFE HF Trial. JACC. Heart failure. 2024. PMID: 38430084. Registry ID: NCT04305717. MeSH: Humans · Male · Middle Aged · Aged · Aged, 80 and over · Female · Heart Failure · Patient Discharge · Stroke Volume · Single-Blind Method · Aftercare · Ventricular Function, Left
Card 2 — ReDS pilot (108 patients): guided care triggered extra diuresis in 30% of the treatment arm, but 30-day readmission did not differ (1.7% versus 4.2%) (Bensimhon 2021)
Study: Randomised pilot study (108 patients)
Population: 108 patients admitted with acute decompensated heart failure (50% men, mean age 73.6 ± 12.6 years, mean ejection fraction 38.5% ± 15.1%) at a single centre, randomly assigned to standard therapy or ReDS-guided therapy, with ReDS measured in all patients once deemed ready for discharge; residual congestion was defined as ReDS of at least 39%.
Summary: ReDS pilot (108 patients): guided care triggered extra diuresis in 30% of the treatment arm, but 30-day readmission did not differ (1.7% versus 4.2%) (Bensimhon 2021)
Result: 32% of patients demonstrated residual lung congestion at the time of proposed discharge. ReDS-guided therapy triggered additional diuresis in 30% (18/60) of the treatment arm (average additional weight loss 5.6 pounds, p = 0.02). Thirty-day heart-failure readmission rates were similar in the treatment and control arms (1.7% versus 4.2%; p = 0.44) — the treatment made no difference to readmission in this sample. Patients discharged as planned with residual congestion (ReDS at least 39%) had a higher 30-day readmission rate than adequately decongested patients (ReDS below 39%): 11.8% versus 1.4% (p = 0.03).
Watch out: Single-centre pilot, not powered for readmission; the congestion-versus-readmission association is observational within the trial (patients were not randomised by congestion level).
Source: Bensimhon D, Alali SA, Curran L et al.. The use of the reds noninvasive lung fluid monitoring system to assess readiness for discharge in patients hospitalized with acute heart failure: A pilot study. Heart & lung : the journal of critical care. 2021. PMID: 32703623. Registry ID: not stated in the record. MeSH: Aged · Aged, 80 and over · Female · Heart Failure · Humans · Lung · Male · Middle Aged · Patient Discharge · Patient Readmission · Pilot Projects · Prospective Studies
Card 3 — Synthesis: the measurement finds real residual congestion; whether acting on it prevents events is split between two small trials
Study: Synthesis
Population: 208 randomised patients across the two trials (100 + 108).
Summary: Synthesis: the measurement finds real residual congestion; whether acting on it prevents events is split between two small trials
Result: Both trials agree that roughly a third of patients judged ready for discharge still carry significant lung fluid by ReDS, and that residual congestion predicts readmission. They disagree on the payoff of acting on the number: ReDS-SAFE HF found a large 1-month event reduction; the pilot found more decongestion without a readmission difference. No large outcomes trial exists.
Watch out: Boundary: live shelves #976 and #6458 own implanted pulmonary-artery pressure monitoring (CardioMEMS); pack #9749 (wave 18) owns the Cordella sensor. This shelf owns only the noninvasive, vest-based ReDS measurement used during and around an acute admission.
Source: Synthesis of the carded records above (PMIDs 38430084, 32703623). Registry ID: NCT04305717 (ReDS-SAFE HF); not stated in the record (pilot).