SourceMed · Shelf #9850 in the ask interface
Plug-based (MANTA) versus suture-based (ProGlide) closure of large-bore femoral access in TAVR (documented N = 726 in 2 randomised trials): no difference in the pilot (10% versus 4% vascular complications) but more complications with the plug in the larger trial (19.4% versus 12.0%)
Shelf #9850 · Heart, vessels, blood pressure & clotting
SPLIT (by trial)
Stamped: 2026-11-28.
Evidence published: 2021–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients undergoing transfemoral transcatheter aortic valve replacement, does a plug-based vascular closure device strategy (MANTA), compared with a suture-based strategy (ProGlide), reduce access-site vascular complications and bleeding?
Balance of the evidence
SPLIT (by trial) — Composition: 2 independent randomised trials (726 patients in total: 210 + 516) plus an individual-patient meta-analysis of the same two trials (722 patients analysed; patients overlap with the trials and are not added to the documented N). The MASH pilot found access-site vascular complications in 10% with the plug-based MANTA device versus 4% with suture-based ProGlide (the treatment made no significant difference; p = 0.16), with less modified device failure on MANTA (20% versus 40%; p < 0.01) but numerically more covered stents and surgical bailouts. The larger CHOICE-CLOSURE trial found the primary endpoint — access-site or access-related major and minor vascular complications — in 19.4% (50/258) with a pure plug-based strategy versus 12.0% (31/258) with a primary suture-based strategy (relative risk 1.61, 95% CI 1.07 to 2.44; P = 0.029), an absolute difference of 7.4 percentage points against the plug, while time to haemostasis was shorter with the plug (80 versus 240 seconds). The patient-level pool of both trials favours the suture-based technique (odds ratio 0.54, 95% CI 0.35 to 0.82 for the primary endpoint). The tested products are named as the publications give them: the MANTA vascular closure device (Teleflex, Wayne, Pennsylvania) and ProGlide (Abbott Vascular, Abbott Park, Illinois). SPLIT (by trial): the pilot found no difference; the larger trial and the pooled analysis favour suture-based closure for complications, with the plug faster to haemostasis.
MeSH: Aged, 80 and over · Catheterization, Peripheral · Female · Femoral Artery · Hemostatic Techniques · Humans · Male · Pilot Projects · Sutures · Transcatheter Aortic Valve Replacement · Treatment Outcome · Vascular Closure Devices · Aged · Aortic Valve · Aortic Valve Stenosis · Hemorrhage · Hemostasis · Peripheral Vascular Diseases · Randomized Controlled Trials as Topic · Suture Techniques
Cards (4)
Card 1 — MASH pilot (210 patients): vascular complications 10% with MANTA versus 4% with ProGlide — no significant difference; device failure lower with MANTA (20% versus 40%) (van Wiechen 2021)
Study: Randomised pilot trial (MASH, 210 patients)
Population: 210 patients undergoing transcatheter aortic valve replacement at 2 centres (median age 81 years, 54% men, median STS score 2.7%), randomly assigned to closure with the MANTA vascular closure device (Teleflex, Wayne, Pennsylvania) or with 2 ProGlides (Abbott Vascular, Abbott Park, Illinois); endpoints adjudicated to VARC-2 definitions.
Summary: MASH pilot (210 patients): vascular complications 10% with MANTA versus 4% with ProGlide — no significant difference; device failure lower with MANTA (20% versus 40%) (van Wiechen 2021)
Result: There was no significant difference in the primary endpoint of access-site-related vascular complications between MANTA and ProGlide (10% versus 4%; p = 0.16). Clinically significant access-site bleeding was similar with both techniques (9% versus 6%; p = 0.57). Modified vascular-closure-device failure occurred less frequently with MANTA than ProGlide (20% versus 40%; p < 0.01); suture-based closure more often required additional closure devices, whereas MANTA numerically needed more covered stents and surgical bailouts. The authors conclude plug-based closure was not superior to suture-based closure.
Watch out: Pilot trial, underpowered for its primary endpoint (the 10% versus 4% point estimates favour suture numerically despite the non-significant p-value); 'modified device failure' is a process endpoint that counts extra manoeuvres differently for the two techniques.
Source: van Wiechen MP, Tchétché D, Ooms JF et al.. Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial. JACC. Cardiovascular interventions. 2021. PMID: 33358648. Registry ID: not stated in the record. MeSH: Aged, 80 and over · Catheterization, Peripheral · Female · Femoral Artery · Hemostatic Techniques · Humans · Male · Pilot Projects · Sutures · Transcatheter Aortic Valve Replacement · Treatment Outcome · Vascular Closure Devices
Card 2 — CHOICE-CLOSURE (516 patients): vascular complications in 19.4% with pure plug-based closure versus 12.0% with primary suture-based closure (relative risk 1.61), but haemostasis was faster with the plug (80 versus 240 seconds) (Abdel-Wahab 2022)
Study: Randomised controlled trial (CHOICE-CLOSURE, 516 patients)
Population: 516 patients undergoing transfemoral transcatheter aortic valve replacement (mean age 80.5 ± 6.1 years, 55.4% men, mean STS score 4.1 ± 2.9%), randomly assigned to a pure plug-based technique (MANTA, Teleflex) with no additional devices or a primary suture-based technique (ProGlide, Abbott Vascular) potentially complemented by a small plug; primary endpoint during index hospitalisation, by VARC-2 criteria.
Summary: CHOICE-CLOSURE (516 patients): vascular complications in 19.4% with pure plug-based closure versus 12.0% with primary suture-based closure (relative risk 1.61), but haemostasis was faster with the plug (80 versus 240 seconds) (Abdel-Wahab 2022)
Result: The primary endpoint (access-site or access-related major and minor vascular complications) occurred in 19.4% (50/258) of the pure plug-based group and 12.0% (31/258) of the primary suture-based group (relative risk 1.61, 95% CI 1.07 to 2.44; P = 0.029) — an absolute difference of 7.4 percentage points. Access-site or access-related bleeding occurred in 11.6% versus 7.4% (relative risk 1.58, 95% CI 0.91 to 2.73; P = 0.133) and device failure in 4.7% versus 5.4% (relative risk 0.86, 95% CI 0.40 to 1.82; P = 0.841). Time to haemostasis was significantly shorter in the pure plug-based group (80 [32–180] versus 240 [174–316] seconds; P < 0.001).
Watch out: The suture arm could be complemented by a small plug, so the contrast is 'pure plug' versus 'primary suture' strategies, not device-versus-device in isolation; most excess complications were minor by VARC-2 grading.
Source: Abdel-Wahab M, Hartung P, Dumpies O et al.. Comparison of a Pure Plug-Based Versus a Primary Suture-Based Vascular Closure Device Strategy for Transfemoral Transcatheter Aortic Valve Replacement: The CHOICE-CLOSURE Randomized Clinical Trial. Circulation. 2022. PMID: 34738828. Registry ID: NCT04459208. MeSH: Aged · Aged, 80 and over · Aortic Valve · Aortic Valve Stenosis · Femoral Artery · Hemorrhage · Hemostasis · Humans · Male · Peripheral Vascular Diseases · Sutures · Transcatheter Aortic Valve Replacement · Treatment Outcome · Vascular Closure Devices
Card 3 — Patient-level meta-analysis of the same 2 trials (722 patients): the primary endpoint was less common with the ProGlide-based technique (odds ratio 0.54) (Dumpies 2025)
Study: Individual patient-level meta-analysis of 2 randomised trials (722 patients)
Population: Individual-patient meta-analysis of the 2 randomised trials above (722 patients undergoing transcatheter aortic valve implantation; the same patients as the two trial cards — not additional patients), with the primary endpoint redefined to VARC-3 criteria.
Summary: Patient-level meta-analysis of the same 2 trials (722 patients): the primary endpoint was less common with the ProGlide-based technique (odds ratio 0.54) (Dumpies 2025)
Result: The primary endpoint (access-site-related vascular complications, VARC-3) was significantly less common after closure with the ProGlide-based technique (odds ratio 0.54, 95% CI 0.35 to 0.82). Access-site-related bleeding events were also less common with the ProGlide-based technique (odds ratio 0.41, 95% CI 0.18 to 0.94). No prespecified subgroup favoured the plug-based technique; outcomes with the MANTA-based technique were better in larger-sized vessels. Patients closed with the ProGlide-based technique were less likely to undergo endovascular stenting or vascular surgery (odds ratio 0.22, 95% CI 0.06 to 0.79).
Watch out: A re-analysis of the same two trials, not new patients; endpoint definitions were harmonised to VARC-3, which is why its analysed total (722) differs slightly from the sum of the trial enrolments (726).
Source: Dumpies O, van Wiechen M, Jobs A et al.. Suture-based versus plug-based closure for large-bore arterial access: an individual patient-level meta-analysis of randomised trials. EuroIntervention. 2025. PMID: 41117657. Registry ID: not stated in the record. MeSH: Humans · Randomized Controlled Trials as Topic · Vascular Closure Devices · Transcatheter Aortic Valve Replacement · Suture Techniques · Hemorrhage · Treatment Outcome · Hemostatic Techniques · Sutures
Card 4 — Synthesis: for large-bore TAVR access, the randomised evidence favours sutures for safety and the plug only for speed
Study: Synthesis
Population: 726 randomised patients across the two trials (the meta-analysis re-pools the same patients).
Summary: Synthesis: for large-bore TAVR access, the randomised evidence favours sutures for safety and the plug only for speed
Result: Neither trial showed a complication advantage for the plug-based device: the pilot was neutral on its primary endpoint and the larger trial found significantly more vascular complications with a pure plug strategy, a finding the patient-level pool confirms. The plug's one consistent win is speed of haemostasis (80 versus 240 seconds in CHOICE-CLOSURE) and, in the pilot, fewer device-failure manoeuvres — paid for with more stent and surgical bailouts when it fails.
Watch out: Boundary: pack #3346 owns closure devices versus manual compression after (small-bore) coronary catheterisation; this shelf owns only the large-bore, plug-versus-suture question in transfemoral TAVR.
Source: Synthesis of the carded records above (PMIDs 33358648, 34738828, 41117657). Registry ID: NCT04459208 (CHOICE-CLOSURE); not stated in the record (MASH, meta-analysis).