Exendin-4 (GLP-1 receptor) imaging to localise insulinoma: 1 individual-patient-data meta-analysis of 179 cases — sensitivity 94% for PET/CT versus sensitivity 63% for SPECT/CT
Shelf #9865 · Diabetes, glucose & metabolism
POSSIBLE
Stamped: 2026-11-28.
Evidence published: 2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with suspected insulinoma, how accurately does exendin-4-based GLP-1 receptor imaging (PET/CT and SPECT/CT) localise the tumour against histopathology?
Balance of the evidence
POSSIBLE — Composition: 1 individual-patient-data meta-analysis of 16 publications (documented N = 179 cases, 316 lesions). For insulinoma localisation, exendin-4 PET/CT had sensitivity 94% and positive predictive value 94%, against sensitivity 63% and positive predictive value 94% for exendin-4 SPECT/CT; sensitivity and specificity are labelled in words wherever they appear on this shelf. No live shelf mentions insulinoma, and no pack on disk asks this question: live #7202 (avexitide, a GLP-1-receptor antagonist) is a treatment question for post-bariatric hypoglycaemia, not an imaging question, and live #7664 (diazoxide choline) treats Prader-Willi hyperphagia — neither localises insulinoma. POSSIBLE: an accuracy shelf built on published cases assembled retrospectively, graded POSSIBLE because case-series assembly invites publication bias and because accuracy shelves are Tier C by rule.
MeSH: Diagnostic Imaging · Exenatide · Humans · Insulinoma · Pancreatic Neoplasms · Positron Emission Tomography Computed Tomography
Cards (2)
Card 1 — Shah 2021 (179 cases, 316 lesions, 16 publications): exendin-4 PET/CT sensitivity 94% for insulinoma localisation versus sensitivity 63% for SPECT/CT; positive predictive value 94% for both
Study: Systematic review and individual-patient-data meta-analysis (accuracy; 179 cases)
Population: Individual-patient-data meta-analysis of the published English literature to August 2020 on GLP-1 receptor targeted imaging in insulinoma, including 179 cases (316 lesions) from 16 publications, with performance calculated against the histopathological diagnosis of insulinoma.
Summary: Shah 2021 (179 cases, 316 lesions, 16 publications): exendin-4 PET/CT sensitivity 94% for insulinoma localisation versus sensitivity 63% for SPECT/CT; positive predictive value 94% for both
Result: For insulinoma localisation, exendin-4 PET/CT performed better (sensitivity 94%, positive predictive value 94%) than exendin-4 SPECT/CT (sensitivity 63%, positive predictive value 94%). Sensitivity was lower in malignant insulinoma cases, whereas specificity was higher in cases with MEN-1 syndrome. False-positive uptakes occurred in Brunner's gland, normal pancreas, and other beta-cell pathologies in a few patients, and false-negative results occurred in pancreatic tail lesions and malignancy; true-negative results suggested the correct diagnosis of other endogenous hyperinsulinaemic hypoglycaemia subtypes. The authors concluded that exendin-4 PET/CT should be preferred over SPECT/CT for insulinoma localisation because of its higher sensitivity and specificity.
Watch out: The pool is assembled from published cases, which over-represents successful localisations; the record does not print a pooled specificity for PET/CT, and none is printed on this shelf. Performance was worse exactly where localisation matters most — malignant tumours and pancreatic tail lesions.
Source: Shah R, Garg R, Majmundar M, Purandare N et al. Clinical Endocrinology. 2021. PMID: 33386617. Registry ID: not stated in the record. MeSH: Diagnostic Imaging · Exenatide · Humans · Insulinoma/diagnostic imaging · Pancreatic Neoplasms/diagnostic imaging · Positron Emission Tomography Computed Tomography
Card 2 — Synthesis — GLP-1 receptor PET/CT is the more sensitive localisation test on the assembled cases; the evidence is case-based, not cohort-based
Study: Synthesis
Population: Synthesis of the single meta-analysis carded on this shelf (documented N = 179 cases); no additional source.
Summary: Synthesis — GLP-1 receptor PET/CT is the more sensitive localisation test on the assembled cases; the evidence is case-based, not cohort-based
Result: On the assembled record, exendin-4 PET/CT localised insulinomas with sensitivity 94% against SPECT/CT's sensitivity 63%, at the same 94% positive predictive value — a modality choice, not a screening claim. The shelf's fence is localisation of suspected insulinoma; it does not cover treatment of hyperinsulinaemic hypoglycaemia (live #7202, #7664) or any other pancreatic imaging question. Tier C by rule for accuracy shelves.
Watch out: Documented N is 179 published cases, not a consecutive clinical cohort; real-world sensitivity in unselected patients is likely lower than 94%.
Source: Synthesis of the carded record above (PMID: 33386617). Registry ID: not stated in the record.