Four-dimensional CT for preoperative localisation of hyperfunctioning parathyroid glands: 1 systematic review of 16 studies (pooled patient total not stated in the record) — per-lesion sensitivity 75% and specificity 85%; per-patient sensitivity 81%
Shelf #9870 · Thyroid & parathyroid
POSSIBLE
Stamped: 2026-11-28.
Evidence published: 2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with primary hyperparathyroidism being prepared for surgery, how accurately does four-dimensional computed tomography localise hyperfunctioning parathyroid glands, per lesion and per patient?
Balance of the evidence
POSSIBLE — Composition: 1 systematic review and meta-analysis of 16 studies (the record does not state the pooled number of patients, and none is printed on this shelf). Per-lesion pooled sensitivity was 75% and pooled specificity was 85%; per-patient pooled sensitivity was 81% with a positive predictive value of 91%. Sensitivity and specificity are labelled in words wherever they appear on this shelf. Heterogeneity was high (I-squared 79% for per-lesion sensitivity and 94.7% for per-lesion specificity), which is stated on the card. This shelf asks about four-dimensional CT only: pack #9025 asks the same localisation question for 18F-fluorocholine PET and pack #9024 asks about intraoperative parathyroid hormone monitoring during surgery — different tests at different points in the pathway. The carded record carries no MeSH list, so this pack's mesh list is empty and the absence is stated plainly rather than reconstructed. POSSIBLE: one heterogeneous meta-analysis, Tier C by rule for accuracy shelves.
Cards (2)
Card 1 — Sun 2021 (16 studies): four-dimensional CT localised hyperfunctioning parathyroid glands with per-lesion sensitivity 75% and specificity 85%, and per-patient sensitivity 81% (positive predictive value 91%) — with high heterogeneity
Study: Systematic review and meta-analysis (accuracy; 16 studies)
Population: Systematic review and meta-analysis of 16 studies of four-dimensional computed tomography for localisation of hyperfunctioning parathyroid glands in patients with primary hyperparathyroidism, reporting pooled diagnostic performance per lesion and per patient with 95% confidence intervals and summary receiver operating characteristic curves. The record does not state the total number of patients across the 16 studies.
Summary: Sun 2021 (16 studies): four-dimensional CT localised hyperfunctioning parathyroid glands with per-lesion sensitivity 75% and specificity 85%, and per-patient sensitivity 81% (positive predictive value 91%) — with high heterogeneity
Result: On a per-lesion level, pooled sensitivity was 75% (95% CI 66–82), pooled specificity was 85% (95% CI 50–97), the positive likelihood ratio was 4.9 (1.1–21.3), the negative likelihood ratio was 0.30 (0.19–0.45), and the diagnostic odds ratio was 17 (3–100), with an area under the curve of 81% (77–84). Heterogeneity was substantial: I-squared 79% for sensitivity and 94.7% for specificity. On a per-patient level, pooled sensitivity was 81% (95% CI 70–90; I-squared 81.9) and the positive predictive value was 91% (82–98; I-squared 80.8). The authors concluded that four-dimensional CT showed moderate sensitivity and specificity for preoperative localisation of hyperfunctioning glands in primary hyperparathyroidism, and that further research is needed. The record carries no MeSH list; none is reconstructed on this card.
Watch out: The per-lesion specificity confidence interval (50–97) is very wide and heterogeneity is high on every pooled figure, so the point estimates (sensitivity 75%, specificity 85%) describe an average across unlike studies, not a stable property of the scan. The record prints no pooled patient total, so the size of the underlying base cannot be verified from the record fetched.
Source: Sun L, Yao J, Hao P, Yang Y et al. Diagnostics. 2021. PMID: 33917261. Registry ID: not stated in the record. MeSH: the record carries no MeSH list.
Card 2 — Synthesis — four-dimensional CT is a moderate-accuracy localisation test on the pooled record, one of three separately homed tests in the parathyroid pathway
Study: Synthesis
Population: Synthesis of the single meta-analysis carded on this shelf (16 studies; pooled patient total not stated in the record); no additional source.
Summary: Synthesis — four-dimensional CT is a moderate-accuracy localisation test on the pooled record, one of three separately homed tests in the parathyroid pathway
Result: The pooled figures — per-lesion sensitivity 75% and specificity 85%, per-patient sensitivity 81% — place four-dimensional CT as a useful but imperfect preoperative map: roughly one in four hyperfunctioning lesions is missed per lesion. This shelf covers CT only; fluorocholine PET localisation is pack #9025 and intraoperative hormone monitoring is pack #9024, and the three are fenced from each other on their faces. Tier C by rule for accuracy shelves.
Watch out: Because the record does not state how many patients the 16 studies contained, this shelf cannot apply the library's sample-size framing to the pooled base; the documented evidence is 16 studies of unstated size.
Source: Synthesis of the carded record above (PMID: 33917261). Registry ID: not stated in the record. MeSH: the record carries no MeSH list, and this pack's mesh list is empty for that reason.