SourceMed · Shelf #9871 in the ask interface

Confirmatory tests for primary aldosteronism (saline infusion, captopril challenge, fludrocortisone suppression, salt loading): 2 systematic reviews (55 studies in the larger; 3,686 patients in the earlier pool) — pooled sensitivity 85–87% and specificity 84–87% for the two best-studied tests, on evidence rated very low certainty

Shelf #9871 · Diabetes, glucose & metabolism

POSSIBLE

Stamped: 2026-11-28.

Evidence published: 2019–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with a positive aldosterone-to-renin screening test, how accurately do the guideline confirmatory tests for primary aldosteronism — saline infusion, captopril challenge, fludrocortisone suppression, and oral salt loading — confirm or exclude the diagnosis against a reference standard?

Balance of the evidence

POSSIBLE — Composition: 2 systematic reviews and meta-analyses of overlapping study pools (55 studies in the 2022 review; 26 articles and 3,686 patients in the 2019 review — the pools overlap and are not added). For the recumbent saline infusion test (26 studies, 3,654 participants in the 2022 review) and the captopril challenge test (25 studies, 2,585 participants), the 2019 review's pooled figures are sensitivity 85% and specificity 87% for saline infusion, and sensitivity 87% and specificity 84% for captopril challenge; sensitivity and specificity are labelled in words wherever they appear on this shelf. The 2022 review's central finding is about the evidence itself: risk of bias was high in more than half of studies, case-control sampling overestimated accuracy about 7-fold, and the certainty of evidence for every test was very low. This shelf asks about confirmation after a positive screen only: live #6062 asks about the screening ratio itself, live #1192 asks whether vein sampling or CT should choose treatment after diagnosis, and pack #6485 asks about cosyntropin use during vein sampling — none evaluates confirmatory testing. POSSIBLE: two overlapping meta-analyses whose own verdict on the underlying evidence is 'very low certainty'; Tier C by rule for accuracy shelves.

MeSH: Captopril · Fludrocortisone · Humans · Hyperaldosteronism · ROC Curve · Sensitivity and Specificity

Cards (3)

Card 1 — Leung 2022 (55 studies): every confirmatory test for primary aldosteronism rests on very-low-certainty evidence — high risk of bias in over half of studies, and case-control designs overestimated accuracy about 7-fold

Study: Systematic review and meta-analysis (accuracy; 55 studies)

Population: Systematic review and meta-analysis of 55 studies evaluating guideline-recommended confirmatory tests for primary aldosteronism against a reference standard: 26 studies (3,654 participants) of the recumbent saline infusion test, 4 studies (633 participants) of the seated saline infusion test, 2 studies (99 participants) of the salt loading test, 7 studies (386 participants) of the fludrocortisone suppression test, and 25 studies (2,585 participants) of the captopril challenge test. Risk of bias was assessed with the QUADAS-2 tool and certainty with GRADE.

Summary: Leung 2022 (55 studies): every confirmatory test for primary aldosteronism rests on very-low-certainty evidence — high risk of bias in over half of studies, and case-control designs overestimated accuracy about 7-fold

Result: Risk of bias was high, affecting more than half of studies, across all domains. Studies with case-control sampling overestimated accuracy by 7-fold (relative diagnostic odds ratio 7.26, 95% CI 2.46–21.43), and partial verification or inconsistent reference standards overestimated accuracy by 5-fold (5.12, 1.48–17.77). There were large variations in how the tests were conducted, interpreted, and verified, and under most scenarios confirmatory testing resulted in an excess of missed cases. The certainty of evidence underlying each test was very low. The authors concluded that recommendations for confirmatory testing in patients with abnormal screening tests and high-probability features of primary aldosteronism are based on very low-quality evidence and that their routine use should be reconsidered. The record's abstract does not print a single pooled sensitivity/specificity pair per test; the pooled pairs on this shelf come from the 2019 review carded beside it.

Watch out: This review's contribution is a verdict on evidence quality, not a usable accuracy number: anyone quoting a confirmatory test's sensitivity from the older literature is quoting studies this review rates at high risk of bias, with design features shown to inflate accuracy several-fold.

Source: Leung AA, Symonds CJ, Hundemer GL, Ronksley PE et al. Hypertension. 2022. PMID: 35652330. Registry ID: not stated in the record. MeSH: Captopril · Fludrocortisone · Humans · Hyperaldosteronism/diagnosis · ROC Curve · Sensitivity and Specificity

Card 2 — Wu 2019 (26 articles, 3,686 patients): captopril challenge pooled sensitivity 87% and specificity 84%; saline infusion pooled sensitivity 85% and specificity 87% — no significant difference between them

Study: Systematic review and meta-analysis (accuracy; 26 articles, 3,686 patients)

Population: Systematic review and meta-analysis of 26 articles including 3,686 patients suspected of primary aldosteronism, evaluating the saline infusion test (10 articles), the captopril challenge test (15 articles), the fludrocortisone suppression test (1 article), and the oral sodium loading test (no eligible articles), with summary receiver operating characteristic curves and pooled sensitivity and specificity.

Summary: Wu 2019 (26 articles, 3,686 patients): captopril challenge pooled sensitivity 87% and specificity 84%; saline infusion pooled sensitivity 85% and specificity 87% — no significant difference between them

Result: For the captopril challenge test, the summary area under the curve was 0.9207, and pooled sensitivity was 0.87 (95% CI 0.84–0.89) and pooled specificity was 0.84 (0.81–0.86). For the saline infusion test, the summary area under the curve was 0.9232, and pooled sensitivity was 0.85 (0.82–0.87) and pooled specificity was 0.87 (0.85–0.89). For the fludrocortisone suppression test (a single article), pooled sensitivity was 0.87 (0.66–0.97) and specificity was 0.95 (0.82–0.99). The authors found no significant differences in diagnostic accuracy between the captopril challenge and saline infusion tests and concluded the captopril test may be a more feasible alternative, being safe and much easier to perform. Read beside the 2022 review carded on this shelf, these pooled pairs come from the same literature that review rates at high risk of bias and very low certainty.

Watch out: The two reviews on this shelf pool overlapping studies, so their figures are not independent confirmations. The fludrocortisone figures rest on one article, and no eligible study of oral sodium loading was found at all — two of the four guideline tests have essentially no pooled accuracy base in this record.

Source: Wu S, Yang J, Hu J, Song Y et al. Clinical Endocrinology. 2019. PMID: 30721529. Registry ID: not stated in the record. MeSH: Diagnostic Techniques, Endocrine/standards · Humans · Hyperaldosteronism/diagnosis

Card 3 — Synthesis — the confirmatory step in primary aldosteronism is guideline-standard but evidence-poor: two overlapping reviews, one set of pooled pairs, one very-low-certainty verdict

Study: Synthesis

Population: Synthesis of the two reviews carded on this shelf (55 studies in the 2022 review; 3,686 patients in the 2019 review's pool; the pools overlap and are not added).

Summary: Synthesis — the confirmatory step in primary aldosteronism is guideline-standard but evidence-poor: two overlapping reviews, one set of pooled pairs, one very-low-certainty verdict

Result: The usable content is twofold: the best pooled accuracy estimates (saline infusion sensitivity 85% / specificity 87%; captopril challenge sensitivity 87% / specificity 84%, from the 2019 review) and the 2022 review's warning that the studies behind every such estimate are at high risk of bias, with certainty rated very low and confirmatory testing producing an excess of missed cases under most scenarios. The shelf's fence is the confirmation step after a positive screen; screening accuracy is live #6062 and post-diagnosis subtyping is live #1192 and pack #6485. Tier C by rule for accuracy shelves.

Watch out: Documented evidence is two meta-analyses of substantially the same primary studies; the shelf must not be read as two independent literatures agreeing.

Source: Synthesis of the carded records above (PMIDs: 35652330, 30721529). Registry IDs: not stated in either record.