SourceMed · Shelf #9877 in the ask interface

Laboratory tests for leptospirosis: conventional PCR on blood pooled at sensitivity 70% / specificity 95% (Cochrane); the microscopic agglutination test itself pooled at only sensitivity 68% / specificity 75% on paired samples

Shelf #9877 · Critical care & sepsis

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2019–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In people with suspected leptospirosis, how accurately do nucleic-acid and antigen detection tests — and the microscopic agglutination test (MAT) used as their reference — identify the disease?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: 1 Cochrane review of 41 studies (5,981 participants) of nucleic-acid and antigen detection tests for leptospirosis (Yang 2019) and 1 Bayesian meta-analysis of the microscopic agglutination test itself (Valente 2024; 15 studies for MAT), carded separately and never pooled together. Sensitivity and specificity are labelled in words wherever they appear on this shelf. The uncomfortable centre of this shelf: the reference test is itself inaccurate — paired-sample MAT pooled at sensitivity 68% and specificity 75%, and single acute-phase MAT at sensitivity 14% — so every index-test pair here is measured against a moving target, and the Cochrane authors say their findings should be interpreted with caution. Conventional PCR on blood pooled at sensitivity 70% and specificity 95%. MEASUREMENT ACCURACY — PARTIAL: accuracy syntheses only, against an imperfect reference standard, Tier C by rule for accuracy shelves.

MeSH: Antibodies, Bacterial · Enzyme-Linked Immunosorbent Assay · Humans · Leptospira · Leptospirosis · Nucleic Acids · Polymerase Chain Reaction · ROC Curve · Sensitivity and Specificity · Serogroup · Bayes Theorem · Agglutination Tests · Immunoglobulin M

Cards (3)

Card 1 — Yang 2019 Cochrane (41 studies, 5,981 participants): conventional PCR sensitivity 70% / specificity 95%; real-time PCR reached only 29–49% sensitivity at 95–85% specificity on the summary curve

Study: Systematic review (accuracy; 41 studies)

Population: Cochrane review of 41 studies evaluating nine index tests (conventional PCR, real-time PCR, nested PCR, PCR performed twice, loop-mediated isothermal amplification, ELISA, dot-ELISA, immunochromatographic lateral flow assay, and dipstick assay) in 5,981 participants (1,834 with and 4,147 without leptospirosis), against MAT alone or a composite reference standard. Methodological quality was often not reported and reference-standard risk of bias was generally high; frozen samples were frequently used. Registry ID: not stated in the record.

Summary: Yang 2019 Cochrane (41 studies, 5,981 participants): conventional PCR sensitivity 70% / specificity 95%; real-time PCR reached only 29–49% sensitivity at 95–85% specificity on the summary curve

Result: The pooled sensitivity of conventional PCR was 70% (95% CI 37% to 90%) and pooled specificity was 95% (95% CI 75% to 99%); excluding studies at high risk of bias in the reference-standard domain, sensitivity was 87% (95% CI 44% to 98%) and specificity 97% (95% CI 60% to 100%). For real-time PCR the summary ROC curve gave, illustratively, sensitivity 49% (95% CI 30% to 68%) at 85% specificity, 40% (95% CI 24% to 59%) at 90% specificity, and 29% (95% CI 15% to 49%) at 95% specificity; median specificity of real-time PCR on blood products was 92%. Only 3 of 15 PCR studies reported sampling timing (1 to 7 days after symptom onset). Two studies suggested PCR may be more sensitive on blood collected early in the disease. The authors conclude there is substantial between-study variability, insufficient evidence to name any one nucleic-acid or antigen test the most accurate, and preliminary evidence only that PCR performs better on early samples.

Watch out: The confidence intervals are the story: PCR sensitivity 70% carries an interval from 37% to 90%, so the pooled pair is a rough centre, not a settled property of the test. Most other index tests in the review could not be pooled at all and are described narratively in the record — no figures for them are printed here.

Source: Yang B, de Vries SG, Ahmed A, Visser BJ et al. Nucleic acid and antigen detection tests for leptospirosis. Cochrane Database of Systematic Reviews. 2019. PMID: 31425612. Registry ID: not stated in the record. MeSH: Antibodies, Bacterial · Enzyme-Linked Immunosorbent Assay · Humans · Leptospira · Leptospirosis · Nucleic Acids · Polymerase Chain Reaction · ROC Curve · Sensitivity and Specificity

Card 2 — Valente 2024 (15 MAT studies): the reference test itself — paired MAT sensitivity 68% / specificity 75%; single acute-phase MAT sensitivity 14% / specificity 86%

Study: Systematic review and meta-analysis (accuracy of the reference test; 15 studies)

Population: Systematic review and Bayesian random-effects meta-analysis of the accuracy of the microscopic agglutination test (MAT) in single acute-phase and paired serum samples, plus PCR targeting the Lfb1 gene (2 studies) and IgM ELISA using Leptospira fainei serovar Hurstbridge antigen (1 study), against blood culture and/or PCR and/or MAT comparators; 15 studies included for the MAT evaluation (11 with single acute-phase serum, 12 with paired sera). Registry ID: not stated in the record.

Summary: Valente 2024 (15 MAT studies): the reference test itself — paired MAT sensitivity 68% / specificity 75%; single acute-phase MAT sensitivity 14% / specificity 86%

Result: For MAT on single acute-phase samples, pooled sensitivity was 14% (95% credible interval 3% to 38%) and pooled specificity 86% (95% credible interval 59% to 96%); predicted values were sensitivity 14% (0% to 90%) and specificity 86% (9% to 100%). For paired MAT samples, pooled sensitivity was 68% (95% credible interval 32% to 92%) and pooled specificity 75% (95% credible interval 45% to 93%); predicted sensitivity 69% (2% to 100%) and specificity 75% (2% to 100%). The authors conclude the accuracy of MAT in paired samples was not high, but it remains the reference standard until a more accurate test is developed, and that larger paired-sample studies would improve certainty.

Watch out: A single acute-phase MAT misses most early cases (sensitivity 14%) — it is a retrospective, paired-sample tool. The predicted intervals (extending to 0–100%) show how little the current paired-sample literature pins down; the Lfb1 PCR and fainei IgM ELISA limbs rested on 2 studies and 1 study and are not given pooled pairs here because the record reports none in its abstract.

Source: Valente M, Bramugy J, Keddie SH, Hopkins H et al. Diagnosis of human leptospirosis: systematic review and meta-analysis of the diagnostic accuracy of the Leptospira microscopic agglutination test, PCR targeting Lfb1, and IgM ELISA to Leptospira fainei serovar Hurstbridge. BMC Infectious Diseases. 2024. PMID: 38326762. Registry ID: not stated in the record. MeSH: Humans · Serogroup · Bayes Theorem · Antibodies, Bacterial · Leptospira · Leptospirosis · Agglutination Tests · Sensitivity and Specificity · Enzyme-Linked Immunosorbent Assay · Immunoglobulin M · Polymerase Chain Reaction

Card 3 — Synthesis — leptospirosis has no accurate early test in the carded evidence: PCR is specific but variably sensitive, and the MAT reference standard is itself only moderately accurate

Study: Synthesis

Population: Synthesis of the two carded reviews (41 studies / 5,981 participants; 15 MAT studies; different index tests and comparators, never pooled); no additional source.

Summary: Synthesis — leptospirosis has no accurate early test in the carded evidence: PCR is specific but variably sensitive, and the MAT reference standard is itself only moderately accurate

Result: The two cards explain each other: index-test accuracy for leptospirosis cannot exceed the quality of its reference, and the reference (paired MAT, sensitivity 68% / specificity 75%) is weakest exactly where clinicians need it — the single acute sample, at sensitivity 14%. Conventional blood PCR (sensitivity 70%, specificity 95%) is the best-pooled early option in the carded evidence, with very wide intervals and a suggestion of better performance on early samples. Tier C by rule for accuracy shelves.

Watch out: Both reviews flag reference-standard bias as pervasive; treat every pair on this shelf as provisional. Culture-based and newer molecular targets were too thinly studied in the carded records to carry figures.

Source: Synthesis of the carded records above (PMIDs: 31425612, 38326762). Registry IDs: not stated in either record.